TEST SITE

Taps

Section Code 1780 : Hose union tap. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either: a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or d. Is legally installed in any premises.

Back To Directory Sections

#2104051

Range of wall mounted hose union taps (brass, chrome plated brass or DZR brass body) incorporating a non-rising spindle headwork with a butterfly handle operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
1780 Taps
Section Subtitle:
Hose union tap. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either: a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or d. Is legally installed in any premises.
WRAS Approval Number:
2104051
Size:
¾” BSP male inlet x 19mmØ hose outlet
Marking:
V&G, WRAS and size on body. Model 13.20202.G20.CP5R-8511 also has ‘DR’ on body.
Installation Requirements:
R001 R040
Expiry date:
30/04/2026
Model:
13.20202.G20.CP03-8510. 13.20202.G20.CP5R-8510. 13.20202.G20.CP5R-8511.
Product Images

Approval Holder:
Zhejiang Valogin Technology Co. Ltd.
Company Name
Zhejiang Valogin Technology Co. Ltd.
Address
Qinggang Technological Ind. Zone, Yuhuan, Zhejiang
Country
China

View All Listings by this Company
Manufacturer:
Zhejiang Valogin Technology Co. Ltd.
Company Name
Zhejiang Valogin Technology Co. Ltd.
Address
Qinggang Technological Ind. Zone, Yuhuan, Zhejiang
Country
China

View All Listings by this Company

Print This Approval


#2104064

Range of wall mounted hose union taps (brass, chrome plated brass or DZR brass body) incorporating a non-rising spindle headwork with a butterfly handle operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
1780 Taps
Section Subtitle:
Hose union tap. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either: a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or d. Is legally installed in any premises.
WRAS Approval Number:
2104064
Size:
¾” BSP male inlet x 19mmØ hose outlet
Marking:
CPS and size on body.
Installation Requirements:
R001 R040
Expiry date:
30/04/2026
Model:
961136
Product Images

Approval Holder:
CITY PLUMBING SUPPLIES HOLDINGS
Company Name
CITY PLUMBING SUPPLIES HOLDINGS
Postcode
NN6 7SL

View All Listings by this Company

Print This Approval


#2104066

Range of wall mounted hose union tap brass body incorporating a non-rising spindle headwork with a butterfly handle operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
1780 Taps
Section Subtitle:
Hose union tap. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either: a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or d. Is legally installed in any premises.
WRAS Approval Number:
2104066
Size:
¾” BSP male inlet x 19mmØ hose outlet
Marking:
TS,size & date of manufacture MM/YY body.
Installation Requirements:
R001 R040
Expiry date:
30/04/2026
Model:
46332

Approval Holder:
TOOLSTATION LTD
Company Name
TOOLSTATION LTD
Address
EXPRESS PARK BRISTOL ROAD BRIDGEWATER
Postcode
TA6 4RN
Country
SOMERSET

View All Listings by this Company

Print This Approval


#2104067

Range of wall mounted hose union taps brass body incorporating a non-rising spindle headwork with a butterfly handle operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
1780 Taps
Section Subtitle:
Hose union tap. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either: a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or d. Is legally installed in any premises.
WRAS Approval Number:
2104067
Size:
¾” BSP male inlet x 19mmØ hose outlet
Marking:
TPK, date of manufacture MM/YY and size on body.
Installation Requirements:
R001 R040
Expiry date:
30/04/2026
Model:
Warrior Brass Bibcock HOSE UNION TAP

Approval Holder:
BSS Industrial
Company Name
BSS Industrial
Address
BOSS Court 7 Barton Close
Postcode
LE19 1SJ
Country
Grove Park
Phone
01162 623232 Telex: 342761

View All Listings by this Company

Print This Approval


#2201305

Range of wall mounted hose union taps incorporating a brass body with a non-rising spindle headwork and a T type operating member. The DIEN-BT&DCV1/2” model incorporates two approved single check valve cartridges (one on the inlet, one on the outlet), however the complete product has not been fully tested to demonstrate it provides backflow protection. Product incorporates a drain plug after the inlet check valve cartridge. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C.

Section:
1780 Taps
Section Subtitle:
Hose union tap. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either: a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or d. Is legally installed in any premises.
WRAS Approval Number:
2201305
Size:
see model
Marking:
Ningbo Dien, size, WRAS and EN1213 on body.
Installation Requirements:
R001 R040
Expiry date:
31/01/2027
Model:
DIEN-BT½” - ½” BSP (M), DIEN-BT¾” - ¾” BSP (M), DIEN-BT&DCV½” - ½” BSP (M).
Product Images

Approval Holder:
Ningbo Dien Trade Co. Ltd.
Company Name
Ningbo Dien Trade Co. Ltd.
Address
UILDING 11 SHUXIANG JINGYUAN YINZHOU DISTRICT
Country
China

View All Listings by this Company

Print This Approval


#2201061

Range of wall mounted hose union taps (brass body or DZR brass body - see model) incorporating a non-rising spindle headwork with a ‘T’-type operating member. The 1BCB001 & 1BCB701 models incorporate two approved single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 14.0 Bar. Maximum operating temperature 85°C.

Section:
1780 Taps
Section Subtitle:
Hose union tap. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either: a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or d. Is legally installed in any premises.
WRAS Approval Number:
2201061
Size:
½” BSP (M).
Marking:
1BCA001: BS1010-2, IDC ‘E’ Logo and size on body. 1BCB001: BS1010, BS6282, IDC ‘E’ logo, CR and size on body. 1BCB701: BS1010, BS6282, IDC ‘E’ logo and size on body.
Installation Requirements:
R001 R040
Expiry date:
31/01/2027
Model:
Brass body: 1BCA001, 1BCB701. DZR brass body: 1BCB001.
Product Images

Approval Holder:
IDC Plumbing & Heating Technology (Beijing) Ltd
Company Name
IDC Plumbing & Heating Technology (Beijing) Ltd
Address
3rd Floor, Unit 2, Building 2, Section A Zhaowei Science & Technology Park No. 14, Jiuxianqiao Road Chaoyang District Beijing
Country
China

View All Listings by this Company
Manufacturer:
IDC Fluid Control Co., Ltd.
Company Name
IDC Fluid Control Co., Ltd.
Address
Mechanical & Elecrical Industrial Area. C, Yuhuan, Taizhou, Zhejiang
Country
China

View All Listings by this Company

Print This Approval


#2201348

Range of wall mounted hose union taps incorporating a brass body with a non-rising spindle headwork and a T type operating member. The JMYG-064 1/2” model incorporates two approved single check valve cartridges (one on the inlet, one on the outlet), however the complete product has not been fully tested to demonstrate it provides backflow protection. Product incorporates a drain plug after the inlet check valve cartridge. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C.

Section:
1780 Taps
Section Subtitle:
Hose union tap. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either: a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or d. Is legally installed in any premises.
WRAS Approval Number:
2201348
Size:
see model
Marking:
JMING, size, WRAS and EN1213 on body.
Installation Requirements:
R001 R040
Expiry date:
31/01/2027
Model:
JMYG-062 - ½” BSP (M), JMYG-063 - ¾” BSP (M), JMYG-064 - ½” BSP (M).

Approval Holder:
Ningbo Jiaming Metal Products Co. Ltd.
Company Name
Ningbo Jiaming Metal Products Co. Ltd.
Address
No.158 JinCi Road Hangzhou Wan New Zone Cixi City
Country
Zhejiang
Phone
+86-574-63575000

View All Listings by this Company

Print This Approval


#2204309

Range of wall mounted hose union taps with brass bodies, incorporating a rising spindle headwork with a ‘T’ type operating member. BC01L & BC01LA models are lockshield type. The BC01A & BC01LA models incorporate an approved check valve cartridge on the inlet and outlet however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
1780 Taps
Section Subtitle:
Hose union tap. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either: a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or d. Is legally installed in any premises.
WRAS Approval Number:
2204309
Size:
½” BSP(M) & ¾” BSP(M)
Marking:
Hongxing on body.
Installation Requirements:
R001 R040
Expiry date:
30/04/2027
Model:
BC01, BC01L, BC01A, BC01LA
Product Images

Approval Holder:
Hongxing Manufacturing Group Ltd
Company Name
Hongxing Manufacturing Group Ltd
Address
Yanye, Qinggang, Yuhuan, Zhejiang
Country
China
Phone
0086-576-87118156
General Email
sales@hongxingmfg.com

View All Listings by this Company

Print This Approval


#2201086

Range of wall mounted hose union taps (brass body or DZR brass body - see model) incorporating a non-rising spindle headwork with a ‘T’-type operating member. Maximum working pressure 14.0 Bar. Maximum operating temperature 85°C.

Section:
1780 Taps
Section Subtitle:
Hose union tap. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either: a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or d. Is legally installed in any premises.
WRAS Approval Number:
2201086
Size:
½” BSP (M).
Marking:
MF, Masterflow -A- Logo, size, CR, WRAS, BS1010-2 & BS6282 on body.
Installation Requirements:
R001 R040
Expiry date:
31/01/2027
Model:
MBHU04 & MBHU04DCV HOSE UNION TAPS
Product Images

Approval Holder:
Masterflow Products Limited
Company Name
Masterflow Products Limited
Address
70-76 Greatbridge Water Street Manchester Lancashire
Postcode
M1 5ES

View All Listings by this Company

Print This Approval


#2201101

Range of wall mounted hose union taps (brass body or DZR brass body - see model) incorporating a non-rising spindle headwork with a ‘T’-type operating member. The CMBHUBDC-D model incorporate two approved single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 14.0 Bar. Maximum operating temperature 85°C.

Section:
1780 Taps
Section Subtitle:
Hose union tap. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either: a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or d. Is legally installed in any premises.
WRAS Approval Number:
2201101
Size:
½” BSP (M).
Marking:
CMBFHUB-D Model MID and size on body. CMBHUBDC-D, CR and size on body.
Installation Requirements:
R001 R040
Expiry date:
31/01/2027
Model:
Brass body: CMBFHUB-D DZR brass body: CMBHUBDC-D

Approval Holder:
Navigator MSL Ltd
Company Name
Navigator MSL Ltd
Address
Mill Road, Sharnbrook, Beds.
Postcode
MK44 1NP
Phone
01234 781234

View All Listings by this Company

Print This Approval


Show Per Page
5102050Show All

Back To Directory Sections

Page of 1

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.