Heaters

Section Code 1465 : Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.

Back To Directory Sections

#2011037

Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. Incorporating a pressure relief valve and expansion vessel. Primary circuit has a maximum working pressure of 3.5 bar and operating temperature of 85°C. Secondary circuit has a maximum working pressure of 10.0 bar and operating temperature of 60°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2011037
Size:
½” BSP male inlet and outlet (DHW). ¾” BSP male inlet and outlet (CH).
Marking:
Lukey on adhesive label on front.
Installation Requirements:
R001 R140
Expiry date:
30/11/2025
Model:
Lukey solution HE (18kW CH & 26kW DHW). Lukey solution HE+ (18kW CH & 26kW DHW). Lukey solution HES+ (18kW CH & 26kW DHW). Lukey solution CBU (18kW CH & 26kW DHW). Beginning February 2021 the models will be named: Lukey 28 HE (18kW CH & 26kW DHW). Lukey 28 HE+ (18kW CH & 26kW DHW). Lukey 28 HES+ (18kW CH & 26kW DHW). Lukey 28 CBU (18kW CH & 26kW DHW).
Product Images

Approval Holder:
Lukey Cassette Boilers (UK) Ltd.
Company Name
Lukey Cassette Boilers (UK) Ltd.
Postcode
BH24 2BB

View All Listings by this Company
Manufacturer:
Lukey Cassette Boilers (UK) Ltd.
Company Name
Lukey Cassette Boilers (UK) Ltd.
Postcode
BH24 2BB

View All Listings by this Company

Print This Approval


#2011033

RINNAI range of wall mounted combination boilers.The unit incorporates a stainless-steel plate heat exchanger pressure relief valve set at 3.0 bar and an expansion vessel on the primary circuit. Maximum working pressure of primary circuit is 2.5 bar and secondary circuit is 10.0 bar. Maximum operating temperature 60˚C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2011033
Size:
Primary circuit: ¾” (M) BSP inlet and outlet. Secondary circuit: ½” (M) BSP inlet and outlet
Marking:
Rinnai on front. Rinnai, model and technical information on adhesive label on side of unit.
Installation Requirements:
R001 R140 R360
Expiry date:
30/11/2025
Model:
ZEN i24 Combi Boiler – REB-KBI2424FF. ZEN i29 Combi Boiler – REB-KBI2929FF. ZEN i34 Combi Boiler – REB-KBI3535FF.
Product Images

Approval Holder:
Rinnai UK Ltd
Company Name
Rinnai UK Ltd
Address
9 Christleton Court Manor Park Runcom
Postcode
WA7 18T
Phone
01928 531 870
General Email
info@rinnaiuk.com

View All Listings by this Company

Print This Approval


#2012051

Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system, incorporating a pressure relief valve set at 3.0 bar and expansion vessel on the primary circuit. The inlet of the replenishing valve between the primary and secondary circuits incorporate a plastic strainer. Maximum working pressure 2.5 bar (primary) and 6.0 bar (secondary). Maximum operating temperature 85˚C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2012051
Size:
½” BSP (M) inlet and outlet Secondary Circuit. ½” BSP (M) replenishing valve. ¾” BSP(M) inlet and outlet primary circuit.
Marking:
Strom on front of body. Model and technical info on adhesive label on side of body.
Installation Requirements:
R001 R140 R360
Expiry date:
31/12/2025
Model:
Strom E range comprising of models: SBSP7C, SBSP11C & SBSP15C. SBTP18C, SBTP21C & SBTP24C. The number in model indicates kW rating.

Approval Holder:
STROM LTD
Company Name
STROM LTD

View All Listings by this Company

Print This Approval


#2101042

LCB700 range of internal and external oil-fired condensing combination boilers providing domestic hot water and pressurised central heating via a plate heat exchanger. The products are supplied with a temporary filling loop which incorporates a combined isolation valve and double check valve assembly (suitable for backflow protection against Fluid Category 3), stainless steel braided EPDM lined flexible hose assembly and an isolation valve. The primary (space heating) circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). Operating parameters: Primary (space heating) circuit: Maximum working pressure 2.5 Bar. Maximum operating temperature 105°C. Secondary (DHW) circuit: Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2101042
Size:
Primary (space heating) circuit: 22mm pushfit. Secondary (DHW) circuit: 15mm pushfit.
Marking:
Navien, model and technical information on adhesive label on rear of front cover.
Installation Requirements:
R001 R140 R360 R430
Expiry date:
31/01/2026
Model:
Internal: LCB700-21LC. LCB700-28LC. LCB700-36LC. External: LCB700-21LCX. LCB700-28LCX. LCB700-36LCX
Product Images

Approval Holder:
KD Navien Co Ltd
Company Name
KD Navien Co Ltd
Address
4F Koami Bldg, 22 Gukhoe daero, 76-gil, Yeongdeungpo-gu, Seoul, 07238 Korea
Phone
+82 2 3489 2200
General Email
www.navien.com

View All Listings by this Company

Print This Approval


#2011358

Range of heat interface units (HIU) with either twin or single stainless steel copper brazed plate heat exchangers (depending on model) providing heating and hot water (twin unit) hot water only, or heating only. The hot water is generated via a plate heat exchanger. The primary (space heating) circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product incorporates a CAb backflow prevention device (suitable for backflow protection against Fluid Category 3) for filling the heating circuit. The inlet and outlet of all circuits incorporate a lever operated spherical valve. Maximum working pressures and operating temperatures: Primary (district heating): 10.0 bar and 85˚C. Domestic hot water (DHW): 10.0 bar and 60˚C. Secondary (space heating): 2.5 bar and 80˚C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2011358
Size:
22mm solder fitting
Marking:
Albion water management, model and other tech info on data label on the side panel.
Installation Requirements:
R001 R140
Expiry date:
30/11/2025
Model:
[Twin Unit]: Standard Twin Plate – heating with 24 plates and hot water with either 14 or 40 plates. Heating connection to cold water by filling loop. Products: TH000240 MTA TWIN 24-40 TH000214 MTA TWIN 24-14 TH001240 MTA TWIN 24-40 HM TH001214 MTA TWIN 24-14 HM [Hot Water Only]: Hot water with either 14 or 40 plates, connection direct to cold water. Products: TH000414 MTA HOT WATER ONLY 00-14 TH000440 MTA HOT WATER ONLY 00-40 TH001414 MTA HOT WATER ONLY 00-14 HM TH001440 MTA HOT WATER ONLY 00-40 HM [Heating Only]: Heating with 40 plates on domestic heating circuit only, connection to cold water via filling loop. Products: TH000340 MTA HEATING ONLY 40-00 TH001340 MTA HEATING ONLY 40-00 HM ‘HM’ stands for heat meter which is on the heating circuit
Product Images

Approval Holder:
Albion Water Management
Company Name
Albion Water Management
Address
30-31 Station Close, Potters Bar, Hertfordshire
Postcode
EN6 1TL
Phone
01707 607230
General Email
water@albiongroup.co.uk

View All Listings by this Company
Manufacturer:
Albion Water Management
Company Name
Albion Water Management
Address
30-31 Station Close, Potters Bar, Hertfordshire
Postcode
EN6 1TL
Phone
01707 607230
General Email
water@albiongroup.co.uk

View All Listings by this Company

Print This Approval


#2107804

Ranges of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system incorporating an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both domestic hot water and primary are controlled via spherical valves. Products are supplied with a rigid filling loop or keyless filling link. Maximum working pressure of the primary circuit is 2.5 bar & maximum supply pressure of the secondary circuit is 8.0 bar. Cold water supply only. Maximum operating temperature 95°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2107804
Size:
Primary: 28mm compression. Secondary: 15mm compression.
Marking:
Baxi on front of boiler.
Installation Requirements:
R001 R140 R360
Expiry date:
31/07/2026
Model:
Baxi 224 Combi (product code 7656160). Baxi 228 Combi (7656161). Baxi 424 Combi (7656162). Baxi 428 Combi (7656163). Baxi 428 Combi LPG (7676760).

Approval Holder:
Baxi Heating UK Ltd.
Company Name
Baxi Heating UK Ltd.
Address
Club Street Bamber Bridge Preston Lancaster
Postcode
PR5 6FN

View All Listings by this Company
Manufacturer:
Baxi Spa
Company Name
Baxi Spa
Address
Via Trozzetti 20 36061 Bassano del Grappa (VI)
Country
Italy
Phone
Tel: +39 0424 517 111 Fax: +39 0424 38089

View All Listings by this Company

Print This Approval


#2111311

Range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both domestic hot water and primary are controlled via spherical valves. The primary circuit has a maximum working pressure of 2.5 bar. The secondary circuit has maximum working pressure of 10.0 bar. Maximum supply temperature is 60°C. Maximum operating temperature of secondary circuit is 85°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2111311
Size:
Primary: 22mm compression inlet/outlet. Secondary: 15mm compression.
Marking:
Worcester and Worcester logo on front of boiler.
Installation Requirements:
R001
Expiry date:
30/11/2026
Model:
7-733-600-371: Greenstar 4000 25 Combi NG. 7-733-600-372: Greenstar 4000 25 Combi LPG. 7-733-600-373: Greenstar 4000 30 Combi NG. 7-733-600-374: Greenstar 4000 30 Combi LPG.
Product Images

Approval Holder:
Bosch Thermotechnology Ltd.
Company Name
Bosch Thermotechnology Ltd.
Address
Cotswold Way Warndon Worcester
Postcode
WR4 9SW
Country
United Kingdom
Phone
0844 892 9900

View All Listings by this Company
Manufacturer:
Bosch Thermotechnology Ltd. Bosch Thermotechnik GmbH. Bosck Termoteknik Sanayu ve Ticaret A.S.
Company Name
Bosch Thermotechnology Ltd. Bosch Thermotechnik GmbH. Bosck Termoteknik Sanayu ve Ticaret A.S.
Address

View All Listings by this Company

Print This Approval


#2111349

Range of floor standing gas fired combination boilers providing domestic hot water via a stainless-steel plate heat exchanger. Unit is supplied with a safety relief valve (8.0 bar). Maximum working pressure 7.5 bar. Maximum operating temperature 85°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2111349
Size:
2 ½” BSP (M)
Marking:
Eco Heating Systems Senator+ on front casing.
Installation Requirements:
R001 R140 R360
Expiry date:
30/11/2026
Model:
Senator 400 WW Senator 500 WW
Product Images

Approval Holder:
Eco Heating Systems B/V
Company Name
Eco Heating Systems B/V
Address
Rigaweg 10, 9723 TH Groningen
Country
Netherlands
Phone
+31 6 86823847
General Email
h.jans@ecohs.nl

View All Listings by this Company
Manufacturer:
Eco Heating Systems B/V
Company Name
Eco Heating Systems B/V
Address
Rigaweg 10, 9723 TH Groningen
Country
Netherlands
Phone
+31 6 86823847
General Email
h.jans@ecohs.nl

View All Listings by this Company

Print This Approval


#2110320

Range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressure relief valve set at 3.0 bar. The supplies to both primary hot water and secondary are controlled via spherical valves. The boilers incorporate a filling loop assembly which incorporates a double check valve assembly (suitable for backflow protection against Fluid Category 3). Primary circuit: Maximum working pressure 2.5 bar. Maximum operating temperature 82°C. Secondary circuit: Maximum working pressure 10.0 bar. Maximum operating temperature 60°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2110320
Size:
22mm compression
Marking:
Worcester (brand of Bosch) on front of boiler. Worcester, address, model, serial No. & other tech info on adhesive label on inside of panel.
Installation Requirements:
R001
Expiry date:
31/10/2026
Model:
Greenstar Highflow range comprising of model numbers: 7 731 600 098 (model code: 440CDi ErP). 7 731 600 099 (440CDi ErP). 7 731 600 100 (550CDi ErP). 7 731 600 101 (550CDi ERP).
Product Images

Approval Holder:
Bosch Thermotechnology Ltd.
Company Name
Bosch Thermotechnology Ltd.
Address
Cotswold Way Warndon Worcester
Postcode
WR4 9SW
Country
United Kingdom
Phone
0844 892 9900

View All Listings by this Company
Manufacturer:
Bosch Thermotechnology Ltd.
Company Name
Bosch Thermotechnology Ltd.
Address
Cotswold Way Warndon Worcester
Postcode
WR4 9SW
Country
United Kingdom
Phone
0844 892 9900

View All Listings by this Company

Print This Approval


#2111371

Range of floor standing gas fired combination boilers providing domestic hot water via a stainless-steel plate heat exchanger. Unit is supplied with a safety relief valve (8.0 bar). Maximum working pressure 7.5 bar. Maximum operating temperature 85°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2111371
Size:
2 ½” BSP (M)
Marking:
Lochinvar on front casing. Lochinvar , model & serial number on adhesive label on body
Installation Requirements:
R001 R140 R360
Expiry date:
30/11/2026
Model:
TTW410 & TTW580 FLOOR STANDING GAS FIRED COMBINATION BOILERS

Approval Holder:
Lochinvar Ltd.
Company Name
Lochinvar Ltd.
Address
7 Lombard Way The MXL Centre Banbury
Postcode
OX16 4TJ
Country
Oxon
Phone
+44 (0) 1295 269981
General Email
general@lochinvar.ltd.uk

View All Listings by this Company

Print This Approval


#2112354

Range of gas fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The cold inlet incorporates an angled spherical valve with a brass body, chromium plated brass ball and a lever operating member. The primary circuit incorporates an expansion vessel, isolation valves on flow and return, drain valve and a pressure relief valve set at 3.0 bar. Maximum working pressure of the primary circuit is 2.5 bar. Maximum working pressure of the secondary circuit is 10.0 bar. Maximum operating temperature for the secondary circuit is 55˚C. Cold supply only.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2112354
Size:
Secondary: 15mm copper tail. Primary: 22mm copper tail.
Marking:
Biasi and Biasi logo on front panel. Biasi, Biasi logo, pressure, model and other technical information on label on inside cover.
Installation Requirements:
R001 R140 R360
Expiry date:
31/12/2026
Model:
Advance Plus 25C ERP, Advance Plus 30C ERP, Advance Plus 35C ERP, M300V.2025 SM, M300V.2530 SM, M300V.3035 SM, M275V.2024 SM, M275V.2428 SM, M275V.2832 SM.
Product Images

Approval Holder:
BSG Caldaie a gas S.p.A.
Company Name
BSG Caldaie a gas S.p.A.
Address
Via Pravolton, 1 - 33170, Pordenone (PN)
Country
Italy
Phone
+39 0434 238311

View All Listings by this Company

Print This Approval


#2111364

Greenstar Heatslave II range of floor standing oil-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system, which incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The cold water inlet incorporates a screwdriver operated spherical valve followed by a plastic flow regulator inserted within the pipework. Maximum working pressure: Primary circuit 2.5 bar. Secondary circuit 10.0 bar. Maximum operating temperature 82°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2111364
Size:
Primary: 28mm copper tail (25/32 models), 22mm copper tail (all other models). Secondary: 15mm inlet x 22mm copper tail outlet.
Marking:
Worcester (brand of Bosch Thermotechnology Ltd) and Worcester logo on front casing. Data label, Worcester and technical information on inside cover.
Installation Requirements:
R001 R140 R360 R430
Expiry date:
30/11/2026
Model:
7 731 600 165 Greenstar Heatslave II 12/18 ErP+, 7 731 600 166 Greenstar Heatslave II 18/25 ErP+, 7 731 600 167 Greenstar Heatslave II 25/32 ErP+, 7 731 600 168 Greenstar Heatslave II EXT 12/18 ErP+, 7 731 600 169 Greenstar Heatslave II EXT 18/25 ErP+, 7 731 600 170 Greenstar Heatslave II EXT 25/32 ErP+, 7 731 600 260 Greenstar Heatslave II 12/18 2022+, 7 731 600 261 Greenstar Heatslave II 18/25 2022+, 7 731 600 262 Greenstar Heatslave II 25/32 2022+, 7 731 600 263 Greenstar Heatslave II EXT 12/18 2022+, 7 731 600 264 Greenstar Heatslave II EXT 18/25 2022+, 7 731 600 265 Greenstar Heatslave II EXT 25/32 2022+.
Product Images

Approval Holder:
Bosch Thermotechnology Ltd.
Company Name
Bosch Thermotechnology Ltd.
Address
Cotswold Way Warndon Worcester
Postcode
WR4 9SW
Country
United Kingdom
Phone
0844 892 9900

View All Listings by this Company
Manufacturer:
Bosch Thermotechnology Ltd.
Company Name
Bosch Thermotechnology Ltd.
Address
Danesmoor Works Pilsley Clay Cross Chesterfield Derbyshire
Postcode
S45 9BY

View All Listings by this Company

Print This Approval


#2201303

Greenstar range of indirect heat interface units providing heating and instantaneous hot water. The heating system incorporates an expansion vessel. The products are sold with or without a prefix kit (see model), which comprises of a mounting bracket that includes spherical valves for all circuits and a pressure relief valve (set at 3.0 bar). Maximum working pressure district heating 10.0 bar. Maximum working pressure space heating 2.5 bar. Maximum working pressure secondary hot water 10.0 bar. Maximum operating temperature 90°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2201303
Size:
Models which incorporate the prefix kit: All circuits 22mm compression. 7-733-601-272 Prefix kit: All circuits 22mm compression inlets x ¾” BSP (M) outlets. Models which do not incorporate the prefix kit: All circuits ¾” captive nut.
Marking:
Worcester on front panel. Worcester, model, address, serial number and other technical information on data label on inside of case.
Installation Requirements:
R001 R140 R360
Expiry date:
31/01/2027
Model:
The following models incorporate the prefix kit: 7-733-600-134: Greenstar HIU KE plus with Heat Meter, 7-733-600-135: Greenstar HIU KE Plus, 7-733-600-136: Greenstar HIU E plus with Heat Meter, 7-733-600-137: Greenstar HIU E plus, 7-733-600-138: Greenstar HIU E with Heat Meter, 7-733-600-139: Greenstar HIU E, 7-733-600-140: Greenstar HIU with Heat Meter & 7-733-600-141: Greenstar HIU. The following models are sold without the prefix kit: 7-735-600-662: Greenstar HIU KE plus with Heat Meter, 7-735-600-661: Greenstar HIU KE Plus, 7-735-600-660: Greenstar HIU E with Heat Meter, 7-735-600-659: Greenstar HIU E, 7-735-600-663: Greenstar HIU with Heat Meter, 7-735-600-658: Greenstar HIU. Prefix kit (which must be installed in conjunction with the aforementioned models): 7-733-601-272. Models added May 2023 (incorporate prefix kit 7-733-601-272): 7-735-600-724: Greenstar HIU E with Heat Meter, 7-735-600-725: Greenstar HIU KE with Heat Meter, 7-735-600-726: Greenstar HIU with Heat Meter.
Product Images

Approval Holder:
Bosch Thermotechnology Ltd.
Company Name
Bosch Thermotechnology Ltd.
Address
Cotswold Way Warndon Worcester
Postcode
WR4 9SW
Country
United Kingdom
Phone
0844 892 9900

View All Listings by this Company
Manufacturer:
Bosch Thermotechnology Ltd.
Company Name
Bosch Thermotechnology Ltd.
Address
Cotswold Way Warndon Worcester
Postcode
WR4 9SW
Country
United Kingdom
Phone
0844 892 9900

View All Listings by this Company

Print This Approval


#2201345

Range of wall mounted, gas-fired, condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and a pressure relief valve set at 3.0 bar. The inlets to the domestic hot water and primary circuits each have a screwdriver operated angled spherical valve. Both include a ½” BSP (M) connection for a filling link. The Greenstar CDi models only are supplied with an integral charging link (CAB device) verified by test (suitable for backflow protection against Fluid Category 3). Maximum working pressure of the primary circuit is 2.5 bar. Maximum working pressure of the secondary circuit is 10.0 bar. Maximum operating temperature of primary circuit is 82°C. Maximum operating temperature of secondary circuit is 60°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2201345
Size:
Secondary: 15mm compression. Primary: 22mm compression.
Marking:
Worcester and Wocester logo on front cover. Worcester, Worcester logo, model number, pressure, temperature and other technical information on data label inside boiler. (Worcester is a brand of Bosch).
Installation Requirements:
R001 R360
Expiry date:
31/01/2027
Proviso:
Greenstar CDi models: Supplied with a filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999. Greenstar Si models: Not supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
7-733-600-056 Greenstar 36CDi Compact ErP, 7-733-600-059 Greenstar 36CDi Compact ErP LPG, 7-733-600-055 Greenstar 32CDi Compact ErP, 7-733-600-058 Greenstar 32CDi Compact ErP LPG, 7-733-600-054 Greenstar 28CDi Compact ErP, 7-733-600-057 Greenstar 28CDi Compact ErP LPG, 7-733-600-050 Greenstar 25Si Compact ErP, 7-733-600-051 Greenstar 25Si Compact ErP LPG, 7-733-600-052 Greenstar 30Si Compact ErP, 7-733-600-053 Greenstar 30Si Compact ErP LPG.
Product Images

Approval Holder:
Bosch Thermotechnology Ltd.
Company Name
Bosch Thermotechnology Ltd.
Address
Cotswold Way Warndon Worcester
Postcode
WR4 9SW
Country
United Kingdom
Phone
0844 892 9900

View All Listings by this Company

Print This Approval


#2205321

Range of electric combination boilers providing heating and instantaneous hot water. The heating system incorporates an expansion vessel and pressure relief valve (set at 3.0 bar). The DHW inlet and outlet incorporate spherical servicing valves. Fittited with a CAB device keyless filling link, verifired by test, suitable for category 3 backlfow protection. Maximum working pressure on central heating circuit 2.5 bar & Domestic Hot Water 10bar. Maximum operating temperature 80°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2205321
Size:
15mm compression x 22mm compression.
Marking:
E.C.A on front casing. Manufacturer, address, model no, QR code and other technical information on side panel.
Installation Requirements:
R001 R140
Expiry date:
31/05/2027
Model:
8116270010 - Arceus/Cure plus/Electus EK 12 MT UK, 8116271010 - Arceus/Cure plus/Electus EK 15 MT UK, 8116272010 - Arceus/Cure plus/Electus EK 18 MT UK 8116273010 - Arceus/Cure plus/Electus EK 24 MT UK & 8116274010 - Arceus/Cure plus/Electus EK 27 MT UK
Product Images

Approval Holder:
Emas Makina Sanayi A.S.
Company Name
Emas Makina Sanayi A.S.
Address
Organize Sanayi Bolgasi 3 Kisim Mustafa Kemal Bulvari N013 Turkey

View All Listings by this Company
Manufacturer:
Emas Makina Sanayi A.S.
Company Name
Emas Makina Sanayi A.S.
Address
Organize Sanayi Bolgasi 3 Kisim Mustafa Kemal Bulvari N013 Turkey

View All Listings by this Company

Print This Approval


#2207350

Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2207350
Size:
Secondary: 15mm compression. Primary: 22mm compression.
Marking:
Ideal heating printed on front casing. Model and size printed on drop down door.
Installation Requirements:
R001 R140 R360
Expiry date:
31/07/2027
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
Logic Max Combi² C24 – UIN 228334, Logic Max Combi² C30 – UIN 228335, Logic Max Combi² C35 – UIN 228336, Logic + Combi² C24 – UIN 228329, Logic + Combi² C30 – UIN 228330, Logic + Combi² C35 – UIN 228331, Logic Combi² C24 – UIN 228307, Logic Combi² C30 – UIN 228308, Logic Combi² C35 – UIN 228309.

Approval Holder:
Ideal Boilers
Company Name
Ideal Boilers
Address
PO Box 103 National Avenue Kingston upon Hull
Postcode
HU5 4JN
Country
East Yorkshire
Phone
+44 (0) 1482 492251
General Email
commercial_heating@idealheating.com

View All Listings by this Company
Manufacturer:
Ideal Boilers
Company Name
Ideal Boilers
Address
PO Box 103 National Avenue Kingston upon Hull
Postcode
HU5 4JN
Country
East Yorkshire
Phone
+44 (0) 1482 492251
General Email
commercial_heating@idealheating.com

View All Listings by this Company

Print This Approval


#2207374

Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2207374
Size:
Secondary: 15mm compression. Primary: 22mm compression.
Marking:
Ideal heating printed on front casing. Model and size printed on drop down door.
Installation Requirements:
R001 R140 R360
Expiry date:
31/07/2027
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
INDEPENDENT COMBI² C24 INDEPENDENT COMBI² C30 INDEPENDENT COMBI² C35

Approval Holder:
Ideal Boilers Ltd
Company Name
Ideal Boilers Ltd
Address
PO Box 103 National Avenue Kingston Upon Hull
Postcode
HU5 4JN
Country
East Yorkshire
Phone
0870 8498056
General Email
enquiries@idealheating.com

View All Listings by this Company

Print This Approval


#2207375

Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2207375
Size:
Secondary: 15mm compression. Primary: 22mm compression.
Marking:
I-MINI² printed on front casing. Model and size printed on drop down door.
Installation Requirements:
R001 R140 R360
Expiry date:
31/07/2027
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
I-MINI²C24 I-MINI²C30 I-MINI²C35

Approval Holder:
Ideal Boilers Ltd
Company Name
Ideal Boilers Ltd
Address
PO Box 103 National Avenue Kingston Upon Hull
Postcode
HU5 4JN
Country
East Yorkshire
Phone
0870 8498056
General Email
enquiries@idealheating.com

View All Listings by this Company

Print This Approval


#2207373

Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2207373
Size:
Secondary: 15mm compression. Primary: 22mm compression.
Marking:
KESTON printed on front casing. Model and size printed on drop down door.
Installation Requirements:
R001 R140 R360
Expiry date:
31/07/2027
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
KESTON COMBI² C30 & KESTON COMBI² C35 COMBINATION BOILERS

Approval Holder:
Ideal Boilers Ltd
Company Name
Ideal Boilers Ltd
Address
PO Box 103 National Avenue Kingston Upon Hull
Postcode
HU5 4JN
Country
East Yorkshire
Phone
0870 8498056
General Email
enquiries@idealheating.com

View All Listings by this Company

Print This Approval


#2306060

Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The products are supplied with a temporary filling loop which incorporates a combined isolation valve and double check valve assembly (suitable for backflow protection against Fluid Category 3), stainless steel braided EPDM lined flexible hose assembly and an isolation valve. The secondary circuit (DHW) incorporates a stainless-steel strainer. The primary circuit incorporates isolation valves on the flow and return. Maximum working pressures: DHW: 10.0 Bar CH:2.5 Bar Maximum operating Temperatures: DHW: 65.0°C CH: 85.0°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2306060
Size:
DHW: 15mm compression CH: 22mm compression
Marking:
Vailant on front cover. Vailant, Model,Pressure, Temperature and other information on adhesive label on rear of body
Installation Requirements:
R001 R140 R360
Expiry date:
30/06/2028
Model:
VUW 20/26CS/1-5 (N-GB) ecoTEC plus 826 VUW 25/32CS/1-5 (N-GB) ecoTEC plus 832 VUW 30/36CS/1-5 (N-GB) ecoTEC plus 836 VUW 30/40CS/1-5 (N-GB) ecoTEC plus 840 VUI 30/40CS/1-5 (N-GB) ecoTEC plus 940

Approval Holder:
Vaillant GmbH
Company Name
Vaillant GmbH
Address
Berghauser Strasse, 40 D-42859 Remscheid
Country
Germany
Phone
Tel: +49 2191 182126

View All Listings by this Company
Manufacturer:
Vaillant Industrial UK Ltd
Company Name
Vaillant Industrial UK Ltd
Address
Nottingham Road Belper Derbyshire
Postcode
DE56 1JT
Phone
01773 824141

View All Listings by this Company

Print This Approval


#2309044

Range of wall mounted combination boilers providing domestic hot water via a heat exchanger and pressurised central heating system. The products can be supplied with a rigid or flexible filling loop or keyless filling link. The flexible and rigid filling loops incorporate a flexible hose or copper pipe, isolation valve, double check valve assembly (suitable for back flow protection against fluid category 3). The keyless filling link incorporates a CAB backflow prevention device (suitable for back flow protection against fluid category 3). The products also incorporate an expansion vessel and pressure relief valve set at 3.0 bar. Maximum working pressure of primary circuit 2.5 bar. Maximum operating temperature of primary circuit 85°C Maximum working pressure of secondary circuit 8.0 bar Maximum operating temperature of secondary circuit 60°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2309044
Size:
¾” BSP (M) (primary circuit). ½” BSP (M) (secondary circuit).
Marking:
Baxi on front cover.
Installation Requirements:
R001 R140 R360
Expiry date:
30/09/2028
Model:
7796586 BAXI 624 COMBI 2 7796587 BAXI 630 COMBI 2 7796588 BAXI 636 COMBI 2 7813609 BAXI 624 COMBI LPG 2 7814304 BAXI 824 COMBI 2 7814305 BAXI 830 COMBI 2 7814306 BAXI 836 COMBI 2 7814307 BAXI 830 COMBI LPG 2 7814308 BAXI 836 COMBI LPG 2 7814309 BAXI ASSURE 524 COMBI 2 7814310 BAXI ASSURE 530 COMBI 2 7814311 BAXI ASSURE 536 COMBI 2 7814312 BAXI ASSURE 530 COMBI LPG 2

Approval Holder:
Baxi Heating UK Limited
Company Name
Baxi Heating UK Limited
Address
Brooks House, Coventry Road, Warwick
Postcode
CV34 3LL

View All Listings by this Company

Print This Approval


#2309313

‘SATK 32’ range of indirect heat interface units providing instantaneous hot water. Domestic hot water is provided via a plate heat exchanger and this circuit incorporates a flow detector, stainless-steel filter and water hammer arrestor. The primary/space heating circuit incorporates a pressure relief valve set at 2.5 bar and an expansion vessel. Maximum working pressure of the domestic hot water circuit is 10.0 bar. Maximum working pressure of the primary circuit is 16.0 bar. Maximum working pressure of the space heating circuit is 2.5 bar. Maximum operating temperature 90°C.

Non-metallic materials and components comply with BS6920 at 85°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2309313
Size:
¾” BSP (M).
Marking:
Caleffi and Caleffi logo moulded on face of unit. Caleffi, Caleffi logo, model number and technical info on data plate inside unit.
Installation Requirements:
R001 R140 R360
Expiry date:
30/09/2028
Model:
SATK32103 - Wall-mounted Indirect Heat Interface Unit for Instantaneous domestic hot water production – DHW capacity 50kW. SATK32105 - Wall-mounted Indirect Heat Interface Unit for Instantaneous domestic hot water production – DHW capacity 60kW. SATK32107 - Wall-mounted Indirect Heat Interface Unit for Instantaneous domestic hot water production – DHW capacity 75kW.

Approval Holder:
Caleffi S.p.A
Company Name
Caleffi S.p.A
Address
PLANT 2. S.R. 229 28010 Fontaneto d'Agogna (NO)
Country
Italy
Phone
+39 0322 8491
General Email
info@caleffi.com

View All Listings by this Company
Manufacturer:
Caleffi S.p.A
Company Name
Caleffi S.p.A
Address
PLANT 2. S.R. 229 28010 Fontaneto d'Agogna (NO)
Country
Italy
Phone
+39 0322 8491
General Email
info@caleffi.com

View All Listings by this Company

Print This Approval


Show Per Page
5102050Show All

Back To Directory Sections

Page of 1

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.