TEST SITE

Taps

Section Code 1780 : Hose union tap. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either: a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or d. Is legally installed in any premises.

Back To Directory Sections

#2104051

Range of wall mounted hose union taps (brass, chrome plated brass or DZR brass body) incorporating a non-rising spindle headwork with a butterfly handle operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
1780 Taps
Section Subtitle:
Hose union tap. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either: a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or d. Is legally installed in any premises.
WRAS Approval Number:
2104051
Size:
¾” BSP male inlet x 19mmØ hose outlet
Marking:
V&G, WRAS and size on body. Model 13.20202.G20.CP5R-8511 also has ‘DR’ on body.
Installation Requirements:
R001 R040
Expiry date:
30/04/2026
Model:
13.20202.G20.CP03-8510. 13.20202.G20.CP5R-8510. 13.20202.G20.CP5R-8511.
Product Images

Approval Holder:
Zhejiang Valogin Technology Co. Ltd.
Company Name
Zhejiang Valogin Technology Co. Ltd.
Address
Qinggang Technological Ind. Zone, Yuhuan, Zhejiang
Country
China

View All Listings by this Company
Manufacturer:
Zhejiang Valogin Technology Co. Ltd.
Company Name
Zhejiang Valogin Technology Co. Ltd.
Address
Qinggang Technological Ind. Zone, Yuhuan, Zhejiang
Country
China

View All Listings by this Company

Print This Approval


#2104064

Range of wall mounted hose union taps (brass, chrome plated brass or DZR brass body) incorporating a non-rising spindle headwork with a butterfly handle operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
1780 Taps
Section Subtitle:
Hose union tap. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either: a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or d. Is legally installed in any premises.
WRAS Approval Number:
2104064
Size:
¾” BSP male inlet x 19mmØ hose outlet
Marking:
CPS and size on body.
Installation Requirements:
R001 R040
Expiry date:
30/04/2026
Model:
961136
Product Images

Approval Holder:
CITY PLUMBING SUPPLIES HOLDINGS
Company Name
CITY PLUMBING SUPPLIES HOLDINGS
Postcode
NN6 7SL

View All Listings by this Company

Print This Approval


#2104066

Range of wall mounted hose union tap brass body incorporating a non-rising spindle headwork with a butterfly handle operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
1780 Taps
Section Subtitle:
Hose union tap. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either: a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or d. Is legally installed in any premises.
WRAS Approval Number:
2104066
Size:
¾” BSP male inlet x 19mmØ hose outlet
Marking:
TS,size & date of manufacture MM/YY body.
Installation Requirements:
R001 R040
Expiry date:
30/04/2026
Model:
46332

Approval Holder:
TOOLSTATION LTD
Company Name
TOOLSTATION LTD
Address
EXPRESS PARK BRISTOL ROAD BRIDGEWATER
Postcode
TA6 4RN
Country
SOMERSET

View All Listings by this Company

Print This Approval


#2104067

Range of wall mounted hose union taps brass body incorporating a non-rising spindle headwork with a butterfly handle operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
1780 Taps
Section Subtitle:
Hose union tap. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either: a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or d. Is legally installed in any premises.
WRAS Approval Number:
2104067
Size:
¾” BSP male inlet x 19mmØ hose outlet
Marking:
TPK, date of manufacture MM/YY and size on body.
Installation Requirements:
R001 R040
Expiry date:
30/04/2026
Model:
Warrior Brass Bibcock HOSE UNION TAP

Approval Holder:
BSS Industrial
Company Name
BSS Industrial
Address
BOSS Court 7 Barton Close
Postcode
LE19 1SJ
Country
Grove Park
Phone
01162 623232 Telex: 342761

View All Listings by this Company

Print This Approval


#2201305

Range of wall mounted hose union taps incorporating a brass body with a non-rising spindle headwork and a T type operating member. The DIEN-BT&DCV1/2” model incorporates two approved single check valve cartridges (one on the inlet, one on the outlet), however the complete product has not been fully tested to demonstrate it provides backflow protection. Product incorporates a drain plug after the inlet check valve cartridge. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C.

Section:
1780 Taps
Section Subtitle:
Hose union tap. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either: a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or d. Is legally installed in any premises.
WRAS Approval Number:
2201305
Size:
see model
Marking:
Ningbo Dien, size, WRAS and EN1213 on body.
Installation Requirements:
R001 R040
Expiry date:
31/01/2027
Model:
DIEN-BT½” - ½” BSP (M), DIEN-BT¾” - ¾” BSP (M), DIEN-BT&DCV½” - ½” BSP (M).
Product Images

Approval Holder:
Ningbo Dien Trade Co. Ltd.
Company Name
Ningbo Dien Trade Co. Ltd.
Address
UILDING 11 SHUXIANG JINGYUAN YINZHOU DISTRICT
Country
China

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1 of 2

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.