TEST SITE

TOOLSTATION LTD Approvals


#2005045

Range of double check valve assemblies consisting of two spring loaded in-line check valve cartridges housed in a DZR brass body with a drain port between the cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Section:
0034 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Type ED - Non-verifiable double check valve.
WRAS Approval Number:
2005045
Size:
See model.
Marking:
TS, CR FLOW ARROW & SIZE ON BODY SIZE ON END NUT
Installation Requirements:
R001
Expiry date:
31/05/2025
Model:
86881: 15mm compression inlet/outlet, 61921: 22mm compression inlet/outlet,

Approval Holder:
TOOLSTATION LTD
Company Name
TOOLSTATION LTD
Address
EXPRESS PARK BRISTOL ROAD BRIDGEWATER
Postcode
TA6 4RN

View All Listings by this Company

Print This Approval


#2007077

Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. The product is supplied with a click type waste. Maximum working pressure 10 bar. Maximum operating temperature 70°C.

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole tap with a single outlet and a fixed spout. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2007077
Size:
Stainless steel braided EPDM lined flexible hose assemblies with ½” captive nut end connections.
Marking:
ebb & flo (brand of Toolstation) on tap body.
Installation Requirements:
R001 R006 R010
Expiry date:
31/07/2025
Model:
20761

Approval Holder:
TOOLSTATION LTD
Company Name
TOOLSTATION LTD
Address
EXPRESS PARK BRISTOL ROAD BRIDGEWATER
Postcode
TA6 4RN

View All Listings by this Company

Print This Approval


#2010403

Single hole, single outlet (swivel) comination tap assembly (chromium plated brass), incorporation a non-rising spindleheadwork with crosstop type operating members. The spout outlets incorporate a metal strainer and either a plastic aerator or alternative flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole tap with a single outlet and a swivel spout. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2010403
Size:
Stainless steel braided EPDM lined hose assembly with ½” BSP captive nut.
Marking:
ebb & flo on tap base
Installation Requirements:
R001 R006 R010
Expiry date:
31/10/2025
Model:
49944

Approval Holder:
TOOLSTATION LTD
Company Name
TOOLSTATION LTD
Address
EXPRESS PARK BRISTOL ROAD BRIDGEWATER
Postcode
TA6 4RN

View All Listings by this Company

Print This Approval


#2010404

Single hole, single outlet (swivel) comination tap assembly (chromium plated brass). Incorporation a ceramic disc headwork with dome type operating members. The spout outlets incorporate a metal strainer and either a plastic aerator or alternative flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole tap with a single outlet and a swivel spout. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2010404
Size:
Stainless steel braided EPDM lined hose assembly with ½” BSP captive nut.
Marking:
ebb & flo on base of tap
Installation Requirements:
R001 R006 R010
Expiry date:
31/10/2025
Model:
88081 COLWELL MONO MIXER COMINATION TAP ASSEMBLY

Approval Holder:
TOOLSTATION LTD
Company Name
TOOLSTATION LTD
Address
EXPRESS PARK BRISTOL ROAD BRIDGEWATER
Postcode
TA6 4RN

View All Listings by this Company

Print This Approval


#2010405

Single hole, single outlet (swivel) comination tap assembly (chromium plated brass), incorporation a ceramic disc headwork with lever type operating members.The spout outlets incorporate a metal strainer and either a plastic aerator or alternative flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole tap with a single outlet and a swivel spout. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2010405
Size:
Stainless steel braided EPDM lined hose assembly with ½” BSP captive nut.
Marking:
ebb & flo on base of tap
Installation Requirements:
R001 R006 R010
Expiry date:
31/10/2025
Model:
26251 Seaton Mono Mixer Kitchen COMINATION TAP ASSEMBLY

Approval Holder:
TOOLSTATION LTD
Company Name
TOOLSTATION LTD
Address
EXPRESS PARK BRISTOL ROAD BRIDGEWATER
Postcode
TA6 4RN

View All Listings by this Company

Print This Approval


#2105807

Range of pillar taps with brass bodies (chrome plated), incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener or aerator. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating pressure 85°C.

Section:
1800 Taps
Section Subtitle:
Pillar tap.
WRAS Approval Number:
2105807
Size:
See model
Marking:
ebb & flo on body
Installation Requirements:
R001 R005
Expiry date:
31/05/2026
Model:
½” BSP (M) 26452 ¾” BSP (M) 62548
Product Images

Approval Holder:
TOOLSTATION LTD
Company Name
TOOLSTATION LTD
Address
EXPRESS PARK BRISTOL ROAD BRIDGEWATER
Postcode
TA6 4RN

View All Listings by this Company

Print This Approval


#2012368

Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated brass). Models 91742, 95660 incorporate a non-rising spindle headwork with dome type operating members. Model 21775 incorporate a non-rising spindle headwork with cross top operating members. Model 77174 incorporate a quarter turn ceramic disc headwork with single lever operating members. The fitting incorporates a manual diverter to the shower outlet The spout outlet incorporates a plastic flow straightener and the products are supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.

Section:
0520 Combination Tap Assemblies
Section Subtitle:
Two hole tap with a single outlet and a fixed spout, incorporating a manually operated diverter to a shower outlet.
WRAS Approval Number:
2012368
Size:
¾” BSP (M)
Marking:
ebb & flo on body
Installation Requirements:
R001 R020
Expiry date:
31/12/2025
Model:
91742, 21775, 95660 & 77174 combination tap assemblies
Product Images

Approval Holder:
TOOLSTATION LTD
Company Name
TOOLSTATION LTD
Address
EXPRESS PARK BRISTOL ROAD BRIDGEWATER
Postcode
TA6 4RN

View All Listings by this Company

Print This Approval


#2104341

Range of bib taps with DZR brass bodies. The inlet and the outlet of the tap incorporates approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
1750 Taps
Section Subtitle:
Draw off bib tap a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building.
WRAS Approval Number:
2104341
Size:
Please see model
Marking:
TS, date of manufacture (MMYY), size & ‘CR’ on body.
Installation Requirements:
R001 R040
Expiry date:
30/04/2026
Model:
84080: ½” BSP (M). 44121: ¾” BSP (M).

Approval Holder:
TOOLSTATION LTD
Company Name
TOOLSTATION LTD
Address
EXPRESS PARK BRISTOL ROAD BRIDGEWATER
Postcode
TA6 4RN

View All Listings by this Company

Print This Approval


#2104066

Range of wall mounted hose union tap brass body incorporating a non-rising spindle headwork with a butterfly handle operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
1780 Taps
Section Subtitle:
Hose union tap. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either: a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or d. Is legally installed in any premises.
WRAS Approval Number:
2104066
Size:
¾” BSP male inlet x 19mmØ hose outlet
Marking:
TS,size & date of manufacture MM/YY body.
Installation Requirements:
R001 R040
Expiry date:
30/04/2026
Model:
46332

Approval Holder:
TOOLSTATION LTD
Company Name
TOOLSTATION LTD
Address
EXPRESS PARK BRISTOL ROAD BRIDGEWATER
Postcode
TA6 4RN

View All Listings by this Company

Print This Approval


#2108804

Range of two hole, single outlet, (fixed) combination tap assemblies (chromium plated brass), Models 49723, 26684 & 18193 incorporate a non rising spindle headwork with dome type operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. . Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Section:
0510 Combination Tap Assemblies
Section Subtitle:
Two hole tap with a single outlet and a fixed spout.
WRAS Approval Number:
2108804
Size:
¾” BSP (M)
Marking:
ebb & flo on body
Installation Requirements:
R001 R009 R010
Expiry date:
31/08/2026
Model:
49723 Contract Bath Mixer Tap, 18193 Traditional Bath Filler & 26684 Solva Bath Filler COMBINATION TAP ASSEMBLIES

Approval Holder:
TOOLSTATION LTD
Company Name
TOOLSTATION LTD
Address
EXPRESS PARK BRISTOL ROAD BRIDGEWATER
Postcode
TA6 4RN

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1 of 4

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.