TEST SITE

Unvented Heating Apparatus

Section Code 1890 :

Back To Directory Sections

#2006003

Range of indirectly heated stainless-steel storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar@90˚C. A safety kit (manifold) consisting of a check valve, strainer, an expansion relief valve set at 6.0 bar and a pressure reducing valve set at 3.5 bar is provided. A tundish, expansion vessel and an approved filling loop is also supplied Maximum working pressure secondary circuit 5.5 bar. Maximum operating pressure primary circuit 2.5 bar. Maximum operating temperature 70˚C.

Section:
1890 Unvented Heating Apparatus
Marking:
Mitsubishi and Ecodan on front of unit. Mitsubishi, model and technical info including pressures and capacity on adhesive label on top of unit.
Installation Requirements:
R001 R140 R530 R360
Expiry date:
30/06/2025
Model:
EHPT20X-MHCW. EHST20C-MHCW. EHST20D-MHCW.

Approval Holder:
Mitsubishi Electric Air Conditioning Systems Europe Ltd
Company Name
Mitsubishi Electric Air Conditioning Systems Europe Ltd
Address
Nettlehill Road, Houston Industrial Estate, Livingston
Postcode
EH54 5EQ
Country
United Kingdom
Phone
01405 44 55 00

View All Listings by this Company
Manufacturer:
Mitsubishi Electric Air Conditioning Systems Europe Ltd
Company Name
Mitsubishi Electric Air Conditioning Systems Europe Ltd
Address
Nettlehill Road, Houston Industrial Estate, Livingston
Postcode
EH54 5EQ
Country
United Kingdom
Phone
01405 44 55 00

View All Listings by this Company

Print This Approval


#2007040

Fabdec ‘Excelsior’ ranges of direct, indirect, solar direct and solar indirect stainless steel insulated unvented hot water storage cylinders with internal expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar 95°C, an inlet manifold consisting of an in-line pressure reducing valve adjustable between 2.7 & 3.3 bar (but factory set @ 3.0 bar), an approved check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2), a pre-set expansion relief valve set at 6.0 bar and a strainer. The product is supplied with a tundish. Maximum supply pressure to pressure reducing valve is 10.0 bar. Maximum working pressure Primary circuit 6.0 bar. Maximum working pressure Secondary circuit 5.5 bar. Maximum operating temperature 85˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2007040
Size:
See model
Marking:
Adhesive label on side of cylinder with manufacturers name (Fabdec), model, address and technical information including temperature, capacity and pressure.
Installation Requirements:
R001 R140 R360
Expiry date:
31/07/2025
Model:
Internal expansion ranges. Excelsior Direct, Indirect, Solar Direct & Solar Indirect Cylinders range: 80ltr, 130ltr, 150ltr, 175ltr, 215ltr, 255ltr, 300ltr, 400ltr, 500ltr.
Product Images

Approval Holder:
Fabdec Ltd
Company Name
Fabdec Ltd
Address
Grange Road Ellesmere Shropshire
Postcode
SY12 9DG

View All Listings by this Company
Manufacturer:
Fabdec Ltd
Company Name
Fabdec Ltd
Address
Grange Road Ellesmere Shropshire
Postcode
SY12 9DG

View All Listings by this Company

Print This Approval


#2011335

Range of vertical cased and insulated direct and indirect unvented stainless steel hot water storage cylinders. The storage cylinders incorporate an internal air bubble to accommodate the expansion of hot water. The DHW circuit has a factory fitted temperature and pressure relief valve set at 10.0@90˚C. The inlet control group includes a pressure reducing valve set at 3.0 bar, single check valve cartridge (verified by test and suitable for backflow protection against Fluid Category 2) and a expansion valve set at 8.0 bar. The products are supplied with a tundish and a motorised valve to be installed on the primary indirect circuit. Maximum supply pressure to the pressure reducing valve is 12.0 bar. Maximum working pressure of primary circuit is 6.0 bar. Maximum secondary circuit is 9.5 bar. Maximum operating temperature 85°C.

Section:
1890 Unvented Heating Apparatus
Size:
22mm compression
Marking:
Gledhill and product & technical information on adhesive label on body
Installation Requirements:
R001 R140 R360
Expiry date:
30/11/2025
Model:
Directs range PLTDR120 Platinum Int Exp Dir 120 PLTDR150 Platinum Int Exp Dir 150 PLTDR180 Platinum Int Exp Dir 180 PLTDR210 Platinum Int Exp Dir 210 PLTDR250 Platinum Int Exp Dir 250 PLTDR300 Platinum Int Exp Dir 300 Indirect range PLTIN120 Platinum Int Exp Ind 120 PLTIN150 Platinum Int Exp Ind 150 PLTIN180 Platinum Int Exp Ind 180 PLTIN210 Platinum Int Exp Ind 210 PLTIN250 Platinum Int Exp Ind 250 PLTIN300 Platinum Int Exp Ind 300 Pre-Plumbed Range PLTIN120PP Platinum Int Exp Ind 120 PP PLTIN150PP Platinum Int Exp Ind 150 PP PLTIN180PP Platinum Int Exp Ind 180 PP PLTIN210PP Platinum Int Exp Ind 210 PP PLTIN250PP Platinum Int Exp Ind 250 PP PLTIN300PP Platinum Int Exp Ind 300 PP System Plus Range PLTIN120PPSP Platinum Int Exp Ind 120 PPSP PLTIN150PPSP Platinum Int Exp Ind 150 PPSP PLTIN180PPSP Platinum Int Exp Ind 180 PPSP PLTIN210PPSP Platinum Int Exp Ind 210 PPSP PLTIN250PPSP Platinum Int Exp Ind 250 PPSP PLTIN300PPSP Platinum Int Exp Ind 300 PPSP System Ready Range PLTIN120PPSR Platinum Int Exp Ind 120 PPSR PLTIN150PPSR Platinum Int Exp Ind 150 PPSR PLTIN180PPSR Platinum Int Exp Ind 180 PPSR PLTIN210PPSR Platinum Int Exp Ind 210 PPSR PLTIN250PPSR Platinum Int Exp Ind 250 PPSR PLTIN300PPSR Platinum Int Exp Ind 300 PPSR
Product Images

Approval Holder:
Gledhill Building Products Ltd
Company Name
Gledhill Building Products Ltd
Address
Sycamore Estate Blackpool
Postcode
FY4 3RL
Phone
(01253) 474439

View All Listings by this Company
Manufacturer:
Gledhill Building Products Ltd
Company Name
Gledhill Building Products Ltd
Address
Sycamore Estate Blackpool
Postcode
FY4 3RL
Phone
(01253) 474439

View All Listings by this Company

Print This Approval


#2007084

Advance Appliance ranges of direct, indirect, solar direct and solar indirect stainless steel insulated unvented hot water storage cylinders with internal expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar 95°C, an inlet manifold consisting of an in-line pressure reducing valve adjustable between 2.7 & 3.3 bar (but factory set @ 3.0 bar), an approved check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2), a pre-set expansion relief valve set at 6.0 bar and a strainer. The product is supplied with a tundish. Maximum supply pressure to pressure reducing valve is 10.0 bar. Maximum working pressure Primary circuit 6.0 bar. Maximum working pressure Secondary circuit 5.5 bar. Maximum operating temperature 85˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2007084
Size:
See model
Marking:
Adhesive label on side of cylinder with Advance Appliances model, address and technical information including temperature, capacity and pressure.
Installation Requirements:
R001 R140 R360
Expiry date:
31/07/2025
Model:
Advances Appliances Indirect - single coil ipp 175 Advance Appliances Indirect- single coil ipp 250

Approval Holder:
Advance Appliances Ltd.
Company Name
Advance Appliances Ltd.
Address
Unit 4 Coppice Side Industrial Estate, Brownhills, Walsall
Postcode
WS8 7EX

View All Listings by this Company

Print This Approval


#2103025

Range of “Tempest” Indirect and direct unvented storage cylinders consisting of factory fitted single or twin coil circuit with either a primary or solar coil. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar@90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures: Secondary circuit 3.0 bar, Primary Circuit 3.0 bar & Solar circuit 5.5 bar. Maximum operating temperature 65°C.

Section:
1890 Unvented Heating Apparatus
Size:
Primary circuit: 1” BSP (F) Secondary circuit: 1” BSP (F) Solar circuit: 1” BSP (F)
Marking:
Telford solar on label. Telford stainless and technical information including capacity and pressures on adhesive label on body.
Installation Requirements:
R001 R140 R360 R530
Expiry date:
31/03/2026
Model:
TSMIXXX - Tempest indirect XXXL single coil unvented cylinder vertical. XXX denotes the capacity in litres, and is replace with any of the following: 090 = 90L, 125 = 125L, 150 = 150L, 170 = 170L, 200 = 200L, 250 = 250L, 300 = 300L, 400 = 400L, 500 = 500L. TSMIXXX/S - Tempest indirect XXXL twin coil boiler & solar unvented cylinder vertical. XXX denotes the capacity in litres, and is replace with any of the following: 170 = 170L, 200 = 200L, 250 = 250L, 300 = 300L, 400 = 400L, 500 = 500L. TSMDXXX - Tempest direct XXXL electric only unvented cylinder vertical. XXX denotes the capacity in litres, and is replace with any of the following: 090 = 90L, 125 = 125L, 150 = 150L, 170 = 170L, 200 = 200L, 250 = 250L, 300 = 300L.
Product Images

Approval Holder:
Telford Copper & Stainless Cylinders Ltd
Company Name
Telford Copper & Stainless Cylinders Ltd
Address
Unit 22 Furrows Business Park Haybridge Road
Postcode
TF1 2DF
Country
Wellington

View All Listings by this Company
Manufacturer:
Telford Copper & Stainless Cylinders Ltd
Company Name
Telford Copper & Stainless Cylinders Ltd
Address
Unit 22 Furrows Business Park Haybridge Road
Postcode
TF1 2DF
Country
Wellington

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1 of 7

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.