Section Code 0450 : Single hole tap with a single outlet and a fixed spout. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.

Back To Directory Sections

#2309925

Single hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a sequential headwork controlling both flow and temperature with single lever type operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 Bar. Maximum operating temperature 85°C.

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole tap with a single outlet and a fixed spout. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2309925
Size:
Model IT1008CP 10mm copper tails Model IT1008FT Stainless steel braided EPDM flexible hose assemblies incorporating ½” captive nut end connections.
Marking:
Model, date of manufacture (MM/YY) on body. Inta on operating member.
Installation Requirements:
R001 R006
Expiry date:
30/09/2028
Model:
IT1008CP IT1008FT

Approval Holder:
Intatec Ltd
Company Name
Intatec Ltd
Address
Airfield Industrial Estate, Hixon, Staffs.
Postcode
ST18 0PF
Country
United Kingdom
Phone
+44 1889 272 199

View All Listings by this Company

Print This Approval


#2010801

Single hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. The product is supplied with a click type waste. Maximum working pressure 5.0 Bar. Maximum operating temperature 70°C.

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole tap with a single outlet and a fixed spout. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2010801
Size:
Stainless steel braided EPDM lined flexible hose assemblies incorporating ½” captive nut end connections with EPDM washers.
Marking:
PPI on rear of body.
Installation Requirements:
R001 R006 R010
Expiry date:
31/10/2025
Model:
143138

Approval Holder:
PPI Xiamen Industry Co Ltd
Company Name
PPI Xiamen Industry Co Ltd
Address
No 88 South Houxiang Road Xinyang Industrial Zone Haicang District Xiamen 361022
Country
China

View All Listings by this Company
Manufacturer:
PPI Xiamen Industry Co Ltd
Company Name
PPI Xiamen Industry Co Ltd
Address
No 88 South Houxiang Road Xinyang Industrial Zone Haicang District Xiamen 361022
Country
China

View All Listings by this Company

Print This Approval


#2010802

Single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating non-rising spindle headworks with cross top operating members. The product is supplied with a click type waste. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole tap with a single outlet and a fixed spout. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2010802
Size:
Stainless steel braided EPDM lined hoses assemblies incorporating ½” captive nut.
Marking:
PPI on rear of body.
Installation Requirements:
R001 R006 R010
Expiry date:
31/10/2025
Model:
143708

Approval Holder:
PPI Xiamen Industry Co Ltd
Company Name
PPI Xiamen Industry Co Ltd
Address
No 88 South Houxiang Road Xinyang Industrial Zone Haicang District Xiamen 361022
Country
China

View All Listings by this Company
Manufacturer:
PPI Xiamen Industry Co Ltd
Company Name
PPI Xiamen Industry Co Ltd
Address
No 88 South Houxiang Road Xinyang Industrial Zone Haicang District Xiamen 361022
Country
China

View All Listings by this Company

Print This Approval


#2004008

Single hole, single outlet, fixed combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. The product is supplied with a click type waste. Maximum working pressure 5.0 Bar. Maximum operating temperature 70°C.

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole tap with a single outlet and a fixed spout. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2004008
Size:
Stainless steel braided EPDM lined flexible hose assemblies with ½” captive nut end connections.
Marking:
PPI on rear of tap body.
Installation Requirements:
R001 R006 R010
Expiry date:
30/04/2025
Model:
162938EX

Approval Holder:
PPI Xiamen Industry Co Ltd
Company Name
PPI Xiamen Industry Co Ltd
Address
No 88 South Houxiang Road Xinyang Industrial Zone Haicang District Xiamen 361022
Country
China

View All Listings by this Company
Manufacturer:
PPI Xiamen Industry Co Ltd
Company Name
PPI Xiamen Industry Co Ltd
Address
No 88 South Houxiang Road Xinyang Industrial Zone Haicang District Xiamen 361022
Country
China

View All Listings by this Company

Print This Approval


#2004012

Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headworks and single lever operating members. The outlet incorporates a plastic flow straighter or aerator and the product is supplied with a coin type waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole tap with a single outlet and a fixed spout. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2004012
Size:
Stainless steel braided EPDM lined flexible hose assemblies incorporating ½” captive nut end connections.
Marking:
Francis Pegler (brand of Comap UK Ltd) on operating member.
Installation Requirements:
R001 R006 R010
Expiry date:
30/04/2025
Model:
Ebro 4G4122

Approval Holder:
Comap UK Limited
Company Name
Comap UK Limited
Address
Unit C6 William Way Moss Ind Estate St Helens Road
Postcode
WN7 3PT
Country
Leigh

View All Listings by this Company
Manufacturer:
COMAP (JIANGMEN)
Company Name
COMAP (JIANGMEN)
Address
98 Longxi High Tech Zone Guangdong

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1 of 76

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.