TEST SITE

Heat Exchangers

Section Code 1350 :

Back To Directory Sections

#2005009

Copper plate heat exchanger with copper connections, incorporating 72 fins. Maximum working pressure Heating circuit 3.0 bar, Sanitary circuit 8.0 bar Maximum operating temperature 99°C

Section:
1350 Heat Exchangers
Size:
18mm female spigot on sanitary circuit 22mm female spigot on heating circuit
Marking:
VALMEX, model number, date of manufacture (WW/YYYY) and other technical information on adhesive label.
Installation Requirements:
R001 R140 R360
Expiry date:
31/05/2025
Model:
COMPACT BITHERMIC HEAT EXCHANGER – 6T OV 26.6X13.6 B225 72 FINS IM WITH COPPER CONNECTIONS.

Print This Approval


#2004353

Domestic hot water heat recovery unit incorporating a stainless steel plate heat exchanger. The product is supplied with two optional 15mm x 15mm compression 90° elbows for installation on the inlet and outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C.

Section:
1350 Heat Exchangers
Size:
15mm compression (15mm copper pipe (nickel plated) including compression nut and olive)
Marking:
Worcester (brand of the Bosch group), serial no., model name and technical information on adhesive label on outer casing.
Installation Requirements:
R001
Expiry date:
30/04/2025
Model:
Greenstar Xtra Flue Gas Recuperator

Approval Holder:
Bosch Termoteknik Isitma ve Klima Sanayi ve Ticaret A.S.
Company Name
Bosch Termoteknik Isitma ve Klima Sanayi ve Ticaret A.S.
Address
Organize Sanayi Bolgesi, 45030 Manisa, Turkey

View All Listings by this Company
Manufacturer:
Bosch Termoteknik Isitma ve Klima Sanayi ve Ticaret A.S.
Company Name
Bosch Termoteknik Isitma ve Klima Sanayi ve Ticaret A.S.
Address
Organize Sanayi Bolgesi, 45030 Manisa, Turkey

View All Listings by this Company

Print This Approval


#2007059

Range of stainless steel plate heat exchangers. The product incorporates a stub pipe with a ½” BSP (F) end connection on the secondary flow (outlet) which can accommodate a control sensor and strap on limit thermostat, (neither of which are supplied or considered part of the approval listing). Maximum working pressure 10.0 bar. Maximum working temperature 85°C.

Section:
1350 Heat Exchangers
Size:
Primary circuit: 2” BSP (M) inlet and outlet. Secondary circuit: 2” BSP (M) inlet/2” BSP (F) outlet.
Marking:
Ormandy Rycroft Engineering, model, serial no., design pressure, temperature and test pressure on adhesive label on end plate.
Installation Requirements:
R001
Expiry date:
31/07/2025
Model:
Core - Breeze L (10-120 plates).
Product Images

Approval Holder:
Maloney Metalcraft (trading as Ormandy Rycroft Engineering)
Company Name
Maloney Metalcraft (trading as Ormandy Rycroft Engineering)

View All Listings by this Company
Manufacturer:
Maloney Metalcraft (trading as Ormandy Rycroft Engineering)
Company Name
Maloney Metalcraft (trading as Ormandy Rycroft Engineering)

View All Listings by this Company

Print This Approval


#2007064

Type "J" range of plate heat exchangers with stainless steel (AISI 304L) bodies and copper welding. Maximum working pressure 3.0 bar (Primary Circuit) and 10.0 bar (Secondary Circuit). Maximum operating temperature 80°C.

Section:
1350 Heat Exchangers
Size:
Ø 15mm
Marking:
Condevo S.p.A, Condevo logo, date of manufacture (DD/MM/YY) on adhesive label on body.
Installation Requirements:
R001
Expiry date:
31/07/2025
Model:
Type "J" range of Heat Exchangers (10 - 34 plates): PP10FJ4R0119011203, PP20FJ4R0119011203, PP22FJ4R0119011203 & PP34FJ4R0119011203. Models added September 2020: PP10FJ6R0119011203, PP20FJ6R0119011203, PP22FJ6R0119011203 & PP34FJ6R0119011203.
Product Images

Approval Holder:
Condevo SpA
Company Name
Condevo SpA
Address
Via Luna, Z.A. 26866 Marudo (LO) Italy

View All Listings by this Company
Manufacturer:
Condevo SpA
Company Name
Condevo SpA
Address
Via Luna, Z.A. 26866 Marudo (LO) Italy

View All Listings by this Company

Print This Approval


#2007348

Range of modular combined heating interface units providing a combination of either hot water, heating or cooling via a plate heat exchanger depending on model options. Heating and cooling circuits incorporate a safety relief valve (set at 3 bar) and expansion vessel and inlet connection can be either top or bottom entry configuration. Maximum working pressure 16 bar (primary, CWS and HWS) 2.5 bar on heating circuit. Maximum operating temperature 85°C.

Section:
1350 Heat Exchangers
Size:
See model.
Marking:
Evinox logo, ECO, XR, Modusat & Evinox on face of unit. Model, Evinox logo & Evinox on back plate. Date of manufacture (DD/MM/YY) Pass & Serial number on inside cover.
Installation Requirements:
R001
Expiry date:
31/07/2025
Proviso:
The filling loop supplied must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
ModuSat SPDHW XR-ECO TYPE A DHW Inlet ¾” BSP (M) SPDHW XR-ECO 30 SPDHW XR-ECO 55 SPDHW XR-ECO 70 TYPE B DHW Inlet 1” BSP(M) SPDHW XR-ECO 100 ModuSat TP XR-ECO TYPE A DHW Inlet ¾” BSP (M) HTG ¾” BSP(M) TP XR-ECO 30 - 10A TP XR-ECO 30 - 20A TP XR-ECO 30 - 30A TP XR-ECO 30 - 40A TP XR-ECO 30 - 10R TP XR-ECO 30 - 20R TP XR-ECO 30 - 30R TP XR-ECO 30 - 40R TP XR-ECO 30 - 50R TP XR-ECO 30 - 60R TP XR-ECO 55 - 10A TP XR-ECO 55 - 20A TP XR-ECO 55 - 30A TP XR-ECO 55 - 40A TP XR-ECO 55 - 10R TP XR-ECO 55 - 20R TP XR-ECO 55 - 30R TP XR-ECO 55 - 40R TP XR-ECO 55 - 50R TP XR-ECO 55 - 60R TP XR-ECO 70 - 10A TP XR-ECO 70 - 20A TP XR-ECO 70 - 30A TP XR-ECO 70 - 40A TP XR-ECO 70 - 10R TP XR-ECO 70 - 20R TP XR-ECO 70 - 30R TP XR-ECO 70 - 40R TP XR-ECO 70 - 50R TP XR-ECO 70 - 60R TYPE B DHW Inlet 1” BSP(M) HTG ¾” BSP(M) TP XR-ECO 100 - 10A TP XR-ECO 100 - 20A TP XR-ECO 100 - 30A TP XR-ECO 100 - 40A TP XR-ECO 100 - 10R TP XR-ECO 100 - 20R TP XR-ECO 100 - 30R TP XR-ECO 100 - 40R TP XR-ECO 100 - 50R TP XR-ECO 100 - 60R ModuSat CHHC XR-ECO TYPE A DHW ¾” BSP(M) HTG ¾” BSP(M) CLG ¾” BSP(M) CHHC XR-ECO 30 - 10A - R20 CHHC XR-ECO 30 - 10A - R30 CHHC XR-ECO 30 - 10A - R40 CHHC XR-ECO 30 - 10A - R50 CHHC XR-ECO 30 - 10A - R60 CHHC XR-ECO 30 - 20A - R20 CHHC XR-ECO 30 - 20A - R30 CHHC XR-ECO 30 - 20A - R40 CHHC XR-ECO 30 - 20A - R50 CHHC XR-ECO 30 - 20A - R60 CHHC XR-ECO 30 - 30A - R20 CHHC XR-ECO 30 - 30A - R30 CHHC XR-ECO 30 - 30A - R40 CHHC XR-ECO 30 - 30A - R50 CHHC XR-ECO 30 - 30A - R60 CHHC XR-ECO 30 - 40A - R20 CHHC XR-ECO 30 - 40A - R30 CHHC XR-ECO 30 - 40A - R40 CHHC XR-ECO 30 - 40A - R50 CHHC XR-ECO 30 - 40A - R60 CHHC XR-ECO 30 - 10R - R20 CHHC XR-ECO 30 - 10R - R30 CHHC XR-ECO 30 - 10R - R40 CHHC XR-ECO 30 - 10R - R50 CHHC XR-ECO 30 - 10R - R60 CHHC XR-ECO 30 - 20R - R20 CHHC XR-ECO 30 - 20R - R30 CHHC XR-ECO 30 - 20R - R40 CHHC XR-ECO 30 - 20R - R50 CHHC XR-ECO 30 - 20R - R60 CHHC XR-ECO 30 - 30R - R20 CHHC XR-ECO 30 - 30R - R30 CHHC XR-ECO 30 - 30R - R40 CHHC XR-ECO 30 - 30R - R50 CHHC XR-ECO 30 - 30R - R60 CHHC XR-ECO 30 - 40R - R20 CHHC XR-ECO 30 - 40R - R30 CHHC XR-ECO 30 - 40R - R40 CHHC XR-ECO 30 - 40R - R50 CHHC XR-ECO 30 - 40R - R60 CHHC XR-ECO 30 - 50R - R20 CHHC XR-ECO 30 - 50R - R30 CHHC XR-ECO 30 - 50R - R40 CHHC XR-ECO 30 - 50R - R50 CHHC XR-ECO 30 - 50R - R60 CHHC XR-ECO 30 - 60R - R20 CHHC XR-ECO 30 - 60R - R30 CHHC XR-ECO 30 - 60R - R40 CHHC XR-ECO 30 - 60R - R50 CHHC XR-ECO 30 - 40R - R60 CHHC XR-ECO 55 - 10A - R20 CHHC XR-ECO 55 - 10A - R30 CHHC XR-ECO 55 - 10A - R40 CHHC XR-ECO 55 - 10A - R50 CHHC XR-ECO 55 - 10A - R60 CHHC XR-ECO 55 - 20A - R20 CHHC XR-ECO 55 - 20A - R30 CHHC XR-ECO 55 - 20A - R40 CHHC XR-ECO 55 - 20A - R50 CHHC XR-ECO 55 - 20A - R60 CHHC XR-ECO 55 - 30A - R20 CHHC XR-ECO 55 - 30A - R30 CHHC XR-ECO 55 - 30A - R40 CHHC XR-ECO 55 - 30A - R50 CHHC XR-ECO 55 - 30A - R60 CHHC XR-ECO 55 - 40A - R20 CHHC XR-ECO 55 - 40A - R30 CHHC XR-ECO 55 - 40A - R40 CHHC XR-ECO 55 - 40A - R50 CHHC XR-ECO 55 - 40A - R60 CHHC XR-ECO 55 - 10R - R20 CHHC XR-ECO 55 - 10R - R30 CHHC XR-ECO 55 - 10R - R40 CHHC XR-ECO 55 - 10R - R50 CHHC XR-ECO 55 - 10R - R60 CHHC XR-ECO 55 - 20R - R20 CHHC XR-ECO 55 - 20R - R30 CHHC XR-ECO 55 - 20R - R40 CHHC XR-ECO 55 - 20R - R50 CHHC XR-ECO 55 - 20R - R60 CHHC XR-ECO 55 - 30R - R20 CHHC XR-ECO 55 - 30R - R30 CHHC XR-ECO 55 - 30R - R40 CHHC XR-ECO 55 - 30R - R50 CHHC XR-ECO 55 - 30R - R60 CHHC XR-ECO 55 - 40R - R20 CHHC XR-ECO 55 - 40R - R30 CHHC XR-ECO 55 - 40R - R40 CHHC XR-ECO 55 - 40R - R50 CHHC XR-ECO 55 - 40R - R60 CHHC XR-ECO 55 - 50R - R20 CHHC XR-ECO 55 - 50R - R30 CHHC XR-ECO 55 - 50R - R40 CHHC XR-ECO 55 - 50R - R50 CHHC XR-ECO 55 - 50R - R60 CHHC XR-ECO 55 - 60R - R20 CHHC XR-ECO 55 - 60R - R30 CHHC XR-ECO 55 - 60R - R40 CHHC XR-ECO 55 - 60R - R50 CHHC XR-ECO 55 - 60R - R60 CHHC XR-ECO 70 - 10A - R20 CHHC XR-ECO 70 - 10A - R30 CHHC XR-ECO 70 - 10A - R40 CHHC XR-ECO 70 - 10A - R50 CHHC XR-ECO 70 - 10A - R60 CHHC XR-ECO 70 - 20A - R20 CHHC XR-ECO 70 - 20A - R30 CHHC XR-ECO 70 - 20A - R40 CHHC XR-ECO 70 - 20A - R50 CHHC XR-ECO 70 - 20A - R60 CHHC XR-ECO 70 - 30A - R20 CHHC XR-ECO 70 - 30A - R30 CHHC XR-ECO 70 - 30A - R40 CHHC XR-ECO 70 - 30A - R50 CHHC XR-ECO 70 - 30A - R60 CHHC XR-ECO 70 - 40A - R20 CHHC XR-ECO 70 - 40A - R30 CHHC XR-ECO 70 - 40A - R40 CHHC XR-ECO 70 - 40A - R50 CHHC XR-ECO 70 - 40A - R60 CHHC XR-ECO 70 - 10R - R20 CHHC XR-ECO 70 - 10R - R30 CHHC XR-ECO 70 - 10R - R40 CHHC XR-ECO 70 - 10R - R50 CHHC XR-ECO 70 - 10R - R60 CHHC XR-ECO 70 - 20R - R20 CHHC XR-ECO 70 - 20R - R30 CHHC XR-ECO 70 - 20R - R40 CHHC XR-ECO 70 - 20R - R50 CHHC XR-ECO 70 - 20R - R60 CHHC XR-ECO 70 - 30R - R20 CHHC XR-ECO 70 - 30R - R30 CHHC XR-ECO 70 - 30R - R40 CHHC XR-ECO 70 - 30R - R50 CHHC XR-ECO 70 - 30R - R60 CHHC XR-ECO 70 - 40R - R20 CHHC XR-ECO 70 - 40R - R30 CHHC XR-ECO 70 - 40R - R40 CHHC XR-ECO 70 - 40R - R50 CHHC XR-ECO 70 - 40R - R60 CHHC XR-ECO 70 - 50R - R20 CHHC XR-ECO 70 - 50R - R30 CHHC XR-ECO 70 - 50R - R40 CHHC XR-ECO 70 - 50R - R50 CHHC XR-ECO 70 - 50R - R60 CHHC XR-ECO 70 - 60R - R20 CHHC XR-ECO 70 - 60R - R30 CHHC XR-ECO 70 - 60R - R40 CHHC XR-ECO 70 - 60R - R50 CHHC XR-ECO 70 - 60R - R60 TYPE B DHW ¾” BSP(M) HTG ¾” BSP(M) CLG 1” BSP(M) CHHC XR-ECO 30 - 10A - R70 CHHC XR-ECO 30 - 20A - R70 CHHC XR-ECO 30 - 30A - R70 CHHC XR-ECO 30 - 40A - R70 CHHC XR-ECO 30 - 10R - R70 CHHC XR-ECO 30 - 20R - R70 CHHC XR-ECO 30 - 30R - R70 CHHC XR-ECO 30 - 40R - R70 CHHC XR-ECO 30 - 50R - R70 CHHC XR-ECO 30 - 60R - R70 CHHC XR-ECO 55 - 10A - R70 CHHC XR-ECO 55 - 20A - R70 CHHC XR-ECO 55 - 30A - R70 CHHC XR-ECO 55 - 40A - R70 CHHC XR-ECO 55 - 10R - R70 CHHC XR-ECO 55 - 20R - R70 CHHC XR-ECO 55 - 30R - R70 CHHC XR-ECO 55 - 40R - R70 CHHC XR-ECO 55 - 50R - R70 CHHC XR-ECO 55 - 60R - R70 CHHC XR-ECO 70 - 10A - R70 CHHC XR-ECO 70 - 20A - R70 CHHC XR-ECO 70 - 30A - R70 CHHC XR-ECO 70 - 40A - R70 CHHC XR-ECO 70 - 10R - R70 CHHC XR-ECO 70 - 20R - R70 CHHC XR-ECO 70 - 30R - R70 CHHC XR-ECO 70 - 40R - R70 CHHC XR-ECO 70 - 50R - R70 CHHC XR-ECO 70 - 60R - R70 ModuSat TYPE C DHW ¾” BSP(M) HTG ¾” BSP(M) CLG 1” BSP(M) CHHC XR-ECO 30 - 10A - B30 CHHC XR-ECO 30 - 20A - B30 CHHC XR-ECO 30 - 30A - B30 CHHC XR-ECO 30 - 40A - B30 CHHC XR-ECO 30 - 10R - B30 CHHC XR-ECO 30 - 20R - B30 CHHC XR-ECO 30 - 30R - B30 CHHC XR-ECO 30 - 40R - B30 CHHC XR-ECO 30 - 50R - B30 CHHC XR-ECO 30 - 60R - B30 CHHC XR-ECO 55 - 10A - B30 CHHC XR-ECO 55 - 20A - B30 CHHC XR-ECO 55 - 30A - B30 CHHC XR-ECO 55 - 40A - B30 CHHC XR-ECO 55 - 10R - B30 CHHC XR-ECO 55 - 20R - B30 CHHC XR-ECO 55 - 30R - B30 CHHC XR-ECO 55 - 40R - B30 CHHC XR-ECO 55 - 50R - B30 CHHC XR-ECO 55 - 60R - B30 CHHC XR-ECO 70 - 10A - B30 CHHC XR-ECO 70 - 20A - B30 CHHC XR-ECO 70 - 30A - B30 CHHC XR-ECO 70 - 40A - B30 CHHC XR-ECO 70 - 10R - B30 CHHC XR-ECO 70 - 20R - B30 CHHC XR-ECO 70 - 30R - B30 CHHC XR-ECO 70 - 40R - B30 CHHC XR-ECO 70 - 50R - B30 CHHC XR-ECO 70 - 60R - B30 CHHC XR-ECO 30 - 10A - B40 CHHC XR-ECO 30 - 20A - B40 CHHC XR-ECO 30 - 30A - B40 CHHC XR-ECO 30 - 40A - B40 CHHC XR-ECO 30 - 10R - B40 CHHC XR-ECO 30 - 20R - B40 CHHC XR-ECO 30 - 30R - B40 CHHC XR-ECO 30 - 40R - B40 CHHC XR-ECO 30 - 50R - B40 CHHC XR-ECO 30 - 60R - B40 CHHC XR-ECO 55 - 10A - B40 CHHC XR-ECO 55 - 20A - B40 CHHC XR-ECO 55 - 30A - B40 CHHC XR-ECO 55 - 40A - B40 CHHC XR-ECO 55 - 10R - B40 CHHC XR-ECO 55 - 20R - B40 CHHC XR-ECO 55 - 30R - B40 CHHC XR-ECO 55 - 40R - B40 CHHC XR-ECO 55 - 50R - B40 CHHC XR-ECO 55 - 60R - B40 CHHC XR-ECO 70 - 10A - B40 CHHC XR-ECO 70 - 20A - B40 CHHC XR-ECO 70 - 30A - B40 CHHC XR-ECO 70 - 40A - B40 CHHC XR-ECO 70 - 10R - B40 CHHC XR-ECO 70 - 20R - B40 CHHC XR-ECO 70 - 30R - B40 CHHC XR-ECO 70 - 40R - B40 CHHC XR-ECO 70 - 50R - B40 CHHC XR-ECO 70 - 60R - B40 ModuSat TYPE E DHW 1” BSP(M) HTG ¾” BSP(M) CLG ¾” BSP(M) CHHC XR-ECO 100 - 10A - R20 CHHC XR-ECO 100 - 10A - R30 CHHC XR-ECO 100 - 10A - R40 CHHC XR-ECO 100 - 10A - R50 CHHC XR-ECO 100 - 10A - R60 CHHC XR-ECO 100 - 20A - R20 CHHC XR-ECO 100 - 20A - R30 CHHC XR-ECO 100 - 20A - R40 CHHC XR-ECO 100 - 20A - R50 CHHC XR-ECO 100 - 20A - R60 CHHC XR-ECO 100 - 30A - R20 CHHC XR-ECO 100 - 30A - R30 CHHC XR-ECO 100 - 30A - R40 CHHC XR-ECO 100 - 30A - R50 CHHC XR-ECO 100 - 30A - R60 CHHC XR-ECO 100 - 40A - R20 CHHC XR-ECO 100 - 40A - R30 CHHC XR-ECO 100 - 40A - R40 CHHC XR-ECO 100 - 40A - R50 CHHC XR-ECO 100 - 40A - R60 CHHC XR-ECO 100 - 10R - R20 CHHC XR-ECO 100 - 10R - R30 CHHC XR-ECO 100 - 10R - R40 CHHC XR-ECO 100 - 10R - R50 CHHC XR-ECO 100 - 10R - R60 CHHC XR-ECO 100 - 20R - R20 CHHC XR-ECO 100 - 20R - R30 CHHC XR-ECO 100 - 20R - R40 CHHC XR-ECO 100 - 20R - R50 CHHC XR-ECO 100 - 20R - R60 CHHC XR-ECO 100 - 30R - R20 CHHC XR-ECO 100 - 30R - R30 CHHC XR-ECO 100 - 30R - R40 CHHC XR-ECO 100 - 30R - R50 CHHC XR-ECO 100 - 30R - R60 CHHC XR-ECO 100 - 40R - R20 CHHC XR-ECO 100 - 40R - R30 CHHC XR-ECO 100 - 40R - R40 CHHC XR-ECO 100 - 40R - R50 CHHC XR-ECO 100 - 40R - R60 CHHC XR-ECO 100 - 50R - R20 CHHC XR-ECO 100 - 50R - R30 CHHC XR-ECO 100 - 50R - R40 CHHC XR-ECO 100 - 50R - R50 CHHC XR-ECO 100 - 50R - R60 CHHC XR-ECO 100 - 60R - R20 CHHC XR-ECO 100 - 60R - R30 CHHC XR-ECO 100 - 60R - R40 CHHC XR-ECO 100 - 60R - R50 CHHC XR-ECO 100 - 60R - R60 ModuSat TYPE F DHW 1” BSP(M) HTG ¾” BSP(M) CLG 1” BSP(M) CHHC XR-ECO 100 - 10A - R70 CHHC XR-ECO 100 - 20A - R70 CHHC XR-ECO 100 - 30A - R70 CHHC XR-ECO 100 - 40A - R70 CHHC XR-ECO 100 - 10R - R70 CHHC XR-ECO 100 - 20R - R70 CHHC XR-ECO 100 - 30R - R70 CHHC XR-ECO 100 - 40R - R70 CHHC XR-ECO 100 - 50R - R70 CHHC XR-ECO 100 - 60R - R70 ModuSat TYPE G DHW 1” BSP(M) HTG ¾” BSP(M) CLG 1” BSP(M) CHHC XR-ECO 100 - 10A - B30 CHHC XR-ECO 100 - 20A - B30 CHHC XR-ECO 100 - 30A - B30 CHHC XR-ECO 100 - 40A - B30 CHHC XR-ECO 100 - 10R - B30 CHHC XR-ECO 100 - 20R - B30 CHHC XR-ECO 100 - 30R - B30 CHHC XR-ECO 100 - 40R - B30 CHHC XR-ECO 100 - 50R - B30 CHHC XR-ECO 100 - 60R - B30 CHHC XR-ECO 100 - 10A - B40 CHHC XR-ECO 100 - 20A - B40 CHHC XR-ECO 100 - 30A - B40 CHHC XR-ECO 100 - 40A - B40 CHHC XR-ECO 100 - 10R - B40 CHHC XR-ECO 100 - 20R - B40 CHHC XR-ECO 100 - 30R - B40 CHHC XR-ECO 100 - 40R - B40 CHHC XR-ECO 100 - 50R - B40 CHHC XR-ECO 100 - 60R - B40
Product Images

Approval Holder:
Evinox Energy Ltd
Company Name
Evinox Energy Ltd
Postcode
KT9 2NY

View All Listings by this Company

Print This Approval


#2009053

Range of stainless steel plate heat exchangers. The product incorporates a stub pipe with a ½” BSP (F) end connection on the secondary flow (outlet) which can accommodate a control sensor and strap on limit thermostat, (neither of which are supplied or considered part of the approval listing). Maximum working pressure 10.0 bar. Maximum working temperature 85°C.

Section:
1350 Heat Exchangers
Size:
Primary circuit: 1½” BSP (M) inlet and outlet. Secondary circuit: 1½” BSP (M) inlet and outlet.
Marking:
Ormandy Rycroft Engineering, model, serial no., design pressure, temperature & test pressure on adhesive label on end plate.
Installation Requirements:
R001
Expiry date:
30/09/2025
Model:
Core - Breeze S (4-86 plates).
Product Images

Approval Holder:
Maloney Metalcraft (trading as Ormandy Rycroft Engineering)
Company Name
Maloney Metalcraft (trading as Ormandy Rycroft Engineering)

View All Listings by this Company
Manufacturer:
Maloney Metalcraft (trading as Ormandy Rycroft Engineering)
Company Name
Maloney Metalcraft (trading as Ormandy Rycroft Engineering)

View All Listings by this Company

Print This Approval


#2009331

Range of indirect heat interface units providing heating and instantaneous hot water. The hot water and space heating is provided via two separate plate heat exchangers. The space heating circuit incorporates an expansion vessel and expansion relief valve (set @ 3.0 bar). The primary circuit only is supplied with isolation valves on the flow and return. Maximum working pressure primary 16.0 bar. Maximum working pressure space heating 2.5 bar. Maximum working pressure secondary hot water (DHW) 10.0 bar. Maximum operating temperature primary 75°C. Maximum operating temperature space heating 85°C. Maximum operating temperature secondary hot water (DHW) 65°C.

Section:
1350 Heat Exchangers
WRAS Approval Number:
2009331
Size:
Primary: 1” BSP (M). Secondary: ¾” BSP (M). DHW: ½” BSP (M).
Marking:
Caleffi on cover. Pressure, model, temperature and other technical information on inside cover.
Installation Requirements:
R001 R360
Expiry date:
30/09/2025
Model:
SATK30105 - 75kW - Indirect HIU. SATK30103 - 50kW - Indirect HIU.

Approval Holder:
Caleffi S.p.A
Company Name
Caleffi S.p.A
Address
PLANT 2. S.R. 229 28010 Fontaneto d'Agogna (NO)
Country
Italy
Phone
+39 0322 8491
General Email
info@caleffi.com

View All Listings by this Company
Manufacturer:
Caleffi S.p.A
Company Name
Caleffi S.p.A
Address
PLANT 2. S.R. 229 28010 Fontaneto d'Agogna (NO)
Country
Italy
Phone
+39 0322 8491
General Email
info@caleffi.com

View All Listings by this Company

Print This Approval


#2010018

Range of stainless-steel plate heat exchangers with copper brazing. Maximum working pressure 30.0 Bar. Maximum operating temperature 100°C.

Section:
1350 Heat Exchangers
Size:
1” BSP (M)
Marking:
UK Exchangers Ltd, maximum pressure, maximum temperature, WRAS, model number and other technical info on adhesive label on body.
Installation Requirements:
R001
Expiry date:
31/10/2025
Model:
UKE-BR050 (20, 30, 40, 50 or 60 plates). UKE-BR050R (20, 30, 40, 50 or 60 plates). UKE-BR095H (20, 30, 40, 50, 60 or 80 plates).
Product Images

Approval Holder:
UK Exchangers Ltd.
Company Name
UK Exchangers Ltd.
Address
Unit 55 Stilebrook Road Olney
Postcode
MK46 5EA
Country
Buckinghamshire

View All Listings by this Company

Print This Approval


#2010032

Range of copper brazed stainless-steel heat exchangers. Maximum working pressure 30.0 bar. Maximum operating temperature 100°C.

Section:
1350 Heat Exchangers
Size:
¾” BSP (M)
Marking:
UK Exchangers Ltd, max pressure, max temperature, WRAS, model number and other technical info on adhesive label on body.
Installation Requirements:
R001
Expiry date:
31/10/2025
Model:
UKE-BR030. UKE-BR040. UKE-BR060H. Available in 10, 20 or 30 plates.
Product Images

Approval Holder:
UK Exchangers Ltd.
Company Name
UK Exchangers Ltd.
Address
Unit 55 Stilebrook Road Olney
Postcode
MK46 5EA
Country
Buckinghamshire

View All Listings by this Company

Print This Approval


#2010035

Range of stainless steel, copper brazed plate type heat exchangers. Maximum working pressure 30.0 bar. Maximum operating temperature 100°C.

Section:
1350 Heat Exchangers
Size:
1 1\2” BSP(M) or 2” BSP (M).
Marking:
UK Exchangers Ltd, max Pressure, max Temperature, WRAS, model number and other technical info on adhesive label on body.
Installation Requirements:
R001
Expiry date:
31/10/2025
Model:
UKE-BR200L UKE-BR200M UKE-BR205 Available in 20/30/40/50/60/80/100/120 Plates.
Product Images

Approval Holder:
UK Exchangers Ltd.
Company Name
UK Exchangers Ltd.
Address
Unit 55 Stilebrook Road Olney
Postcode
MK46 5EA
Country
Buckinghamshire

View All Listings by this Company

Print This Approval


#2010374

Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The inlet and outlet of all circuits incorporates lever operated spherical valves with brass bodies. 274.xx9x.696 models all have the following additional items over the 274.xx1x.696 models: Heatmeter on the primary circuit, a flushing bypass between the primary and space heating circuits and a safety relief valve (set at 10.0 bar) on the cold supply to the heat exchanger of the domestic hot water circuit. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 9.5 bar and 60˚C. Secondary (space heating): 2.5 bar and 85˚C.

Section:
1350 Heat Exchangers
WRAS Approval Number:
2010374
Size:
¾” BSP (F)
Marking:
Taconova Group AG and other technical information on control panel. Pressure, temperature, WRAS, type and other technical information on inside cover.
Installation Requirements:
R001 R140 R360
Expiry date:
31/10/2025
Model:
274.2411.696 HL3000E 10/26. 274.2491.696 HL3000E 10/26. 274.2611.696 HL3000E 10/40. 274.2691.696 HL3000E 10/40. 274.4411.696 HL3000E 16/26. 274.4491.696 HL3000E 16/26. 274.4611.696 HL3000E 16/40. 274.4691.696 HL3000E 16/40. 274.6411.696 HL3000E 26/26. 274.6491.696 HL3000E 26/26. 274.6611.696 HL3000E 26/40. 274.6691.696 HL3000E 26/40. 274.6711.696 HL3000E 26/50. 274.6791.696 HL3000E 26/50. Where final part of code denotes the number of plates on the heat exchanger, e.g. 10/26, 10 = number of plates on the space heating circuit, 26 = the number of plates on the domestic hot water circuit.
Product Images

Approval Holder:
HeatliNK
Company Name
HeatliNK
Postcode
S6 1JF

View All Listings by this Company
Manufacturer:
Taconova Production s.r.o.
Company Name
Taconova Production s.r.o.
Address
Nova UL. C 627, CZ-38232 Velesin, Czech Republic

View All Listings by this Company

Print This Approval


#2010310

Uponor Combi Port range of indirect heat interface units providing heating and instantaneous hot water. The heating system incorporates an expansion vessel and pressure relief valve (set at 3.0 bar).Some units have optional ball valve sets. Primary side heating 85°C and 2.5 bar. Secondary side, space heating 60°C and 2.5 bar. Secondary side DHW 60°C and 4.0 bar.

Section:
1350 Heat Exchangers
Size:
See model
Marking:
Uponor, model no, serial no & date of manufacture (DD.MM.YYYY) on inside cover.
Installation Requirements:
R001 R140 R360
Expiry date:
31/10/2025
Model:
Uponor Combi Port base XU: 1095642 15l/min 1095643 21l/min 1095644 29l/min Optional ball valve set 101802 for models 1095644 & 1095642 Uponor Combi Port PRO XU: 1095636 15l.min 1095637 21l/min Optional Ball valve set 1037536
Product Images

Approval Holder:
Uponor GmbH
Company Name
Uponor GmbH
Address
Industriestraße 56, 97437 Hassfurt
Country
Germany
Phone
0034916853600

View All Listings by this Company

Print This Approval


#2011003

Range of copper brazed, stainless steel heat exchangers in various sizes (4-300 plates, see model). Models size X8T-SC-S Maximum working pressure primary circuit: 32.0 bar Maximum working pressure secondary circuit: 26.0 bar Maximum operating temperature: 99°C Models size 10T-SC-M Maximum working pressure primary circuit: 41.0 bar Maximum working pressure secondary circuit: 36.0 bar Maximum operating temperature: 99°C Models size 15T-SC-M Maximum working pressure primary circuit: 45.0 bar Maximum working pressure secondary circuit: 45 bar Maximum operating temperature: 99°C Models size 16DW-SC-S Maximum working pressure primary circuit: 16.0 bar Maximum working pressure secondary circuit: 16.0 bar Maximum operating temperature: 99°C Models size 16DW-SC-M Maximum working pressure primary circuit: 45.0 bar Maximum working pressure secondary circuit: 45.0 bar Maximum operating temperature: 99°C Models size 220-SC-S Maximum working pressure primary circuit: 25.0 bar Maximum working pressure secondary circuit: 25.0 bars Maximum operating temperature: 99°C Models size 320HT-SC-S Maximum working pressure primary circuit: 33.0 bar Maximum working pressure secondary circuit: 29.0 bar Maximum operating temperature: 99°C Models size 320LT-SC-S Maximum working pressure primary circuit: 33.0 bars Maximum working pressure secondary circuit: 29.0 bars Maximum operating temperature: 99°C

Section:
1350 Heat Exchangers
Size:
See model
Marking:
SWEP, year of manufacture and technical information on adhesive label on body
Installation Requirements:
R001
Expiry date:
30/11/2025
Model:
Models X8T-SC-S Connection types: ½”, ¾” " External threaded male Number of plates minimum: 4 Number of plates maximum: 60 Models 10T-SC-M Connection types: 3/8” to 1 1/4 " External threaded male Number of plates minimum: 4 Number of plates maximum: 140 Models 15T-SC-M Connection types: ½” to 1” External threaded male Number of plates minimum: 4 Number of plates maximum: 60 Models 16DW-SC-S Connection types: ½” to 1 1/4” External threaded male Number of plates minimum: 4 Number of plates maximum: 140 Models 16DW-SC-M Connection types: ½” to 1 1/4” External threaded male Number of plates minimum: 4 Number of plates maximum: 140 Models 220-SC-S Connection types: 1” to 2 1/2” External threaded male Number of plates minimum: 4 Number of plates maximum: 300 Models 320HT-SC-S Connection types: 1 ½” to 2 1/2” External threaded male Number of plates minimum: 4 Number of plates maximum: 300 Models 320LT-SC-S Connection types: 1 ½” to 3” External threaded male Number of plates minimum: 4 Number of plates maximum: 260
Product Images

Approval Holder:
SWEP International AB
Company Name
SWEP International AB
Address
Box 105, 26122 Landskrona, Sweden

View All Listings by this Company
Manufacturer:
SWEP Slovakia s.r.o | SWEP Malaysia sdn Bhd
Company Name
SWEP Slovakia s.r.o | SWEP Malaysia sdn Bhd
Address

View All Listings by this Company

Print This Approval


#2012058

Range of waste water heat recovery systems incorporating a twin wall copper coil (iZi models) or stainless steel (PiPe models). Maximum working pressure 10.0 bar. Cold water use only.

Section:
1350 Heat Exchangers
Size:
½” BSP (M) (iZi 30 & 40) or ¾” BSP (F) (PiPe 65 & 70)
Marking:
Zypho, Model, WRAS and technical info on adhesive label located on plastic casing.
Installation Requirements:
R001
Expiry date:
31/12/2025
Model:
ZYPHO iZi 30, ZYPHO iZi 40, ZYPHO PiPe 65, ZYPHO PiPe 70
Product Images

Approval Holder:
Zypho, SA
Company Name
Zypho, SA
Country
Portugal
Phone
+351 210 991 351
General Email
b2b@zypho.pt

View All Listings by this Company
Manufacturer:
Zypho, SA
Company Name
Zypho, SA
Country
Portugal
Phone
+351 210 991 351
General Email
b2b@zypho.pt

View All Listings by this Company

Print This Approval


#2011035

Range of indirect heat interface units with copper brazed stainless-steel heat exchangers, providing heating and instantaneous hot water. The products incorporate an expansion vessel on the cold-water supply to the plate heat exchanger and a safety relief valve on the space heating circuit set @ 3.0 bar. The domestic hot water and space heating circuit are both fitted with drain valves incorporating cover caps. Maximum working pressures: Domestic hot water 10.0 bar. Space Heating 2.5 bar. District Heating 3.0 bar. Maximum operating temperature 85˚C.

Section:
1350 Heat Exchangers
WRAS Approval Number:
2011035
Size:
Domestic hot water and District heating circuits: ¾” BSP (M) inlet/outlet. Space heating circuit: ¾” BSP captive nut inlet/outlet.
Marking:
YGHP on front cover. YGHP, model number, company address and technical info on adhesive label on side of body.
Installation Requirements:
R001 R140 R360 R511
Expiry date:
30/11/2025
Proviso:
Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
YGINDRADSTD33/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 33kW / HTG 10kW. YGINDRADSTD40/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 40kW / HTG 10kW. YGINDRADSTD50/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 50kW / HTG 10kW. YGINDRADSTD60/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 60kW / HTG 10kW. YGINDRADSTD75/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 75kW / HTG 10kW. YGINDRADSTD90/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 90kW / HTG 10kW. YGINDRADSTD120/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 120kW / HTG 10kW. Models added March 2021: YGINDUFHSTD33/10.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 33kW / HTG 10kW YGINDUFHSTD40/10.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 40kW / HTG 10kW YGINDUFHSTD50/10.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 50kW / HTG 10kW YGINDUFHSTD60/10.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 60kW / HTG 10kW YGINDUFHSTD75/15.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 75kW / HTG 15kW YGINDUFHSTD90/15.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 90kW / HTG 15kW YGINDUFHSTD120/30.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 120kW / HTG 30kW
Product Images

Approval Holder:
YGHP
Company Name
YGHP

View All Listings by this Company

Print This Approval


#2101035

Range of stainless-steel heat exchangers. Maximum working pressure of primary Circuit 3.0 bar. Maximum working pressure of secondary Circuit 10.0 bar. Maximum operating temperature 80˚C

Section:
1350 Heat Exchangers
Size:
Primary Circuit ¾” captive nut x ¾” BSP (M) Sanitary Circuit 21mm (OD) Spigot Fitting x ½” BSP (M)
Marking:
Condevo SpA, serial number and date of manufacture (DD/MM/YY) on adhesive label on body.
Installation Requirements:
R001
Expiry date:
31/01/2026
Model:
Type E 12439 PP11CE6V02, PP21CE6V02 & PP33CE6V02. Type E 12440 PP10CE6H02, PP22CE6H02 & PP34CE6H02.
Product Images

Approval Holder:
Condevo SpA
Company Name
Condevo SpA
Address
Via Luna, Z.A. 26866 Marudo (LO) Italy

View All Listings by this Company
Manufacturer:
Condevo SpA
Company Name
Condevo SpA
Address
Via Luna, Z.A. 26866 Marudo (LO) Italy

View All Listings by this Company

Print This Approval


#2012353

Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.

Section:
1350 Heat Exchangers
Size:
¾” BSP (M)
Marking:
Inta logo, address, serial number, technical & pressure information on label inside case.
Installation Requirements:
R001
Expiry date:
31/12/2025
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
HIPER2TPSZ80
Product Images

Approval Holder:
Intatec Ltd
Company Name
Intatec Ltd
Address
Airfield Industrial Estate, Hixon, Staffs.
Postcode
ST18 0PF
Country
United Kingdom
Phone
+44 1889 272 199

View All Listings by this Company

Print This Approval


#2010078

Range of RINNAI continuous flow water heaters with stainless steel plate heat exchangers providing heating and instantaneous hot water .The hot water is generated via a plate heat exchanger. Also supplied is a drain valve and a flow sensing device. Maximum working pressure - 10 bar Maximum working pressure - 85˚C

Section:
1350 Heat Exchangers
Size:
¾” Male inlet and outlet
Marking:
RINNAI on body and data badge including date of manufacture (YY/MM)
Installation Requirements:
R001
Expiry date:
31/10/2025
Model:
REU-N3237FFC-E – N1600i (57.9kW / 29Kg) REU-N3237WC-E – N1600e (57.9kW / 29Kg) REU-N2635FFC-E – N1300i (47kW / 28Kg) REU-N2635WC-E – N1300e (47kW / 28Kg)
Product Images

Approval Holder:
Rinnai UK Ltd
Company Name
Rinnai UK Ltd
Address
9 Christleton Court Manor Park Runcom
Postcode
WA7 18T
Phone
01928 531 870
General Email
info@rinnaiuk.com

View All Listings by this Company
Manufacturer:
Rinnai UK Ltd
Company Name
Rinnai UK Ltd
Address
9 Christleton Court Manor Park Runcom
Postcode
WA7 18T
Phone
01928 531 870
General Email
info@rinnaiuk.com

View All Listings by this Company

Print This Approval


#2012362

Shower waste water heat recovery unit, consisting of a PVC-U waste pipe with an internal copper tube which provides a double wall separation between the waste water and cold mains supply. Maximum working pressure 10.0 bar. Maximum operating temperature 30°C.

Section:
1350 Heat Exchangers
Size:
½” BSP (F).
Marking:
Recoup logo, pipe ID outside wall, PVC-U 63x2.0, 16028740 kiwa, 5 16-01-19 11.40, PVC MET HERGERBUIKGRANTIE on adhesive label on outside wall.
Installation Requirements:
R001 R008 R150
Expiry date:
31/12/2025
Model:
Recoup Pipe HEX: R-PHX-01 (2.1m length). Recoup Pipe HEX-Rd: R-PHX-03 (1.7m length).

Approval Holder:
Recoup Energy Solutions Ltd.
Company Name
Recoup Energy Solutions Ltd.
Address
Trumpeter House Trumpeter Way Long Stratton Norfolk
Postcode
NR15 2DY
Phone
+44 (0) 1379 844 010

View All Listings by this Company

Print This Approval


#2012365

Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.

Section:
1350 Heat Exchangers
Size:
¾” BSP (M)
Marking:
BAXI ON FRONT OF CASING. BAXI, address, serial number, technical & pressure information on label inside case.
Installation Requirements:
R001
Expiry date:
31/12/2025
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
BAXI ASSURE HIMAX TWIN ID 90/30 ELECTRONICALLY CONTROLLED HEAT INTERFACE UNITS

Approval Holder:
Baxi Heating UK Limited
Company Name
Baxi Heating UK Limited
Address
Brooks House, Coventry Road, Warwick
Postcode
CV34 3LL

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1 of 3

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.