Section Code 0684 : Tap with a non-touch methods of flow control and a single inlet. Products listed in this section utilise flow control methods that do not require touch to activate.
Back To Directory SectionsRange of single hole, single outlet (fixed) electronically controlled tap assemblies (either stainless steel or brass bodies in a variety of finishes). Flow is controlled via two solenoid valves (housed in a control box) activated via an infra-red sensor, the inlets to the control box incorporate stainless steel strainers. The temperature is controlled independently via a ceramic cartridge with a dome type operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet, fixed electronically controlled tap assembly with brass bodies (various finishes), incorporating a solenoid valve controlling the flow which is activated via an infrared sensor. The spout outlet incorporates a plastic aerator. The product is supplied with a stainless steel braided PEX lined flexible hose assembly and a metal backnut. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass), flow is controlled by a solenoid valve activated via an infra-red sensor. The tap connects to the solenoid valve via a copper tail with a ½” BSP (F) captive nut and a fibre washer. The product is supplied with a combined TPE washer and stainless steel strainer to be installed on the inlet to the solenoid. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass), flow is controlled by a solenoid valve activated via an infra-red sensor. The tap connects to the solenoid valve via a copper tail with a ½” BSP (F) captive nut and a fibre washer. The product is supplied with a combined TPE washer and stainless steel strainer to be installed on the inlet to the solenoid. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass), flow is controlled by a solenoid valve activated via an infra-red sensor. The tap connects to the solenoid valve via a copper tail with a ½” BSP (F) captive nut and a fibre washer. The product is supplied with a combined TPE washer and stainless steel strainer to be installed on the inlet to the solenoid. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) electronically operated, tap assemblies (chromium plated brass). Flow is controlled via solenoid valve and actuated by a touch sensor. The spout outlets incorporate a plastic aerator, supplied with stainless steel strainers. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly (stainless steel). The flow is controlled by a solenoid valve that is actuated via an infra-red sensor on the spout. The inlet to the solenoid valve incorporates a stainless steel strainer. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two hole, single outlet (fixed) mains electric or battery controlled tap assemblies (chromium plated brass) incorporating approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection . The flow is controlled via a solenoid valve activated via an infra-red sensor. The inlet to the solenoid incorporates a stainless-steel strainer. The tap is supplied with spherical valves for both hot and cold inlets. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Single hole, single outlet, fixed electronically controlled tap assemblies with brass bodies (chrome plated), incorporating a solenoid valve controlling the flow which is activated via an infrared sensor. The spout outlet incorporates a plastic aerator, and the product is supplied with a metal backnut. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, electronically controlled spout outlets with stainless steel bodies. Flow is controlled via a solenoid valve activated via an infra-red sensor. Models AT07-102 and AT07-103 are supplied with a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) electronically operated tap assemblies incorporating brass bodies (various finishes). Flow is controlled via solenoid valve and actuated by a touch sensor. The hose inlet incorporates a flow restrictor and the spout outlets incorporate a plastic aerator. Maximum working pressure 7.5 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) with a pull-out spray mechanism. Flow is controlled via a ceramic cartridge headwork with a single lever operating member incorporating an infra-red sensor on the swivel arm which operates a solenoid valve. The spout outlet incorporates a plastic aerator and a hand spray mechanism, and the product is supplied with metal backnuts. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of deck mounted, electronically operated combination tap assemblies (chromium plated brass). The flow is controlled by a solenoid valve which is actuated via an infrared sensor on the spout. The spout outlet incorporates a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) with a pull-out spray mechanism. Flow is controlled via a ceramic cartridge headwork with a single lever operating member incorporating an infra-red sensor on the swivel arm which operates a solenoid valve. The spout outlet incorporates a plastic aerator and a hand spray mechanism, and the product is supplied with metal backnuts. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass). Flow is controlled by a solenoid valve activated by via an infra-red sensor. The inlet to the solenoid incorporates a stainless-steel strainer. The product is supplied with a stainless-steel braided EPDM lined flexible hose assembly for installation between the solenoid valve and the tap body. The spout outlet incorporates a plastic aerator with built in flow regulator. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
single hole, single outlet (swivel) combination tap assemblies (various finishes) with a pull-out spray mechanism. Flow is controlled via a ceramic cartridge headwork with a single lever operating member incorporating an infra-red sensor on the swivel arm which operates a solenoid valve. The spout outlet incorporates a plastic aerator and a hand spray mechanism, and the product is supplied with metal backnuts. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Deck mounted single hole, single outlet (fixed) electronically controlled tap assembly (chromium plated brass). The flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. Tempearture is controlled from a separate control unit incorporating a thermostatic cartridge, which is operated by a single lever on the side of the unit. The spout connects to the unit via a (transparent) PEX-b pipe. The inlets of the control unit incorporate a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The outlet of the unit incorporates a plastic flow regulator. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of deck mounted, single hole, single outlet (fixed) electronically controlled tap assemblies (brass body - various finishes, see model). Flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. The inlet hose incorporates an approved single check valve cartridge, however, the complete assembly has not been tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of deck mounted, single hole, single outlet (fixed) electronically controlled tap assemblies (brass body - various finishes, see model). Flow is controlled by a solenoid valve activated via an infra-red sensor. The product incorporates a manual temperature control operated by a single lever on the side of the body. The spout outlet incorporates a plastic aerator. The inlet hoses incorporate an approved single check valve cartridge, however, the complete assembly has not been tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
A range of wall mounted two hole single outlet (fixed) electronically controlled tap assemblies with brass bodies (various finishes). Flow is controlled by a solenoid valve activated by via an infra-red sensor on the underside of the tap. The inlets of the function block incorporate stainless steel strainers, plastic silencers and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Page 1 of 7
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.