TEST SITE

Combination Tap Assemblies

Section Code 0445 : Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.

Back To Directory Sections

#2201321

Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating ceramic disc headworks and single lever operating members. The cold inlet to the tap incorporates incorporates an approved check valve cartridge which has been verified by test (as suitable for backflow protection against Fluid Category 2). The inlet of hose to the pull-out spray incorporates an approved check valve cartridge which has not been fully tested to demonstrate it provides backflow protection. The outlet of pull-out spray incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2201321
Size:
Stainless steel braided, PEX lined flexible hose assemblies incorporating ½” captive nut end connections.
Marking:
Lota on body
Installation Requirements:
R001 R009 R010 R090
Expiry date:
31/01/2027
Model:
63433-00X 63433-01X 63433-03X X denotes finish and can be replaced with: 01 - Chrome 04 - Brushed Nickel 08 - Stainless steel 4408 - Brushed Brass 6801 - Matt Black 5804 - Heirloom Silver 0402 - Brushed Nickel PVD
Product Images

Approval Holder:
Xiamen Lota International Co., Ltd.
Company Name
Xiamen Lota International Co., Ltd.
Address
No.61 Xingnan Road, Jimei District, Xiamen, 361022
Country
China
Phone
86-592-6665866

View All Listings by this Company
Manufacturer:
Xiamen Lota International Co., Ltd.
Company Name
Xiamen Lota International Co., Ltd.
Address
No.61 Xingnan Road, Jimei District, Xiamen, 361022
Country
China
Phone
86-592-6665866

View All Listings by this Company

Print This Approval


#2201328

Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating ceramic disc headworks and single lever operating members. The cold inlet to the tap incorporates incorporates an approved check valve cartridge which has been verified by test (as suitable for backflow protection against Fluid Category 2). The inlet of hose to the pull-out spray incorporates an approved check valve cartridge which has not been fully tested to demonstrate it provides backflow protection. The outlet of pull-out spray incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2201328
Size:
Stainless-steel braided PEX line flexible hose assemblies incorporating ½” BSP captive nut end connections.
Marking:
Lota on body.
Installation Requirements:
R001 R009 R010 R090
Expiry date:
31/01/2027
Model:
63435-00X Pull out Kitchen mixer 63437-01X Pull out Kitchen mixer 63442-00X Pull out Kitchen mixer 63440-00X Kitchen mixer 63440-01X Kitchen mixer X denotes finish and can be replaced: 01 - Chrome 04 - Brushed Nickel 08 - Stainless steel 4408 - Brushed Brass 6801 - Matt Black 5804 - Heirloom Silver 0402 - Brushed Nickel PVD
Product Images

Approval Holder:
Xiamen Lota International Co., Ltd.
Company Name
Xiamen Lota International Co., Ltd.
Address
No.61 Xingnan Road, Jimei District, Xiamen, 361022
Country
China
Phone
86-592-6665866

View All Listings by this Company
Manufacturer:
Xiamen Lota International Co., Ltd.
Company Name
Xiamen Lota International Co., Ltd.
Address
No.61 Xingnan Road, Jimei District, Xiamen, 361022
Country
China
Phone
86-592-6665866

View All Listings by this Company

Print This Approval


#2201351

Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating ceramic disc headworks and single lever operating members. The cold inlet to the tap incorporates incorporates an approved check valve cartridge which has been verified by test (as suitable for backflow protection against Fluid Category 2). The inlet of hose to the pull-out spray incorporates an approved check valve cartridge which has not been fully tested to demonstrate it provides backflow protection. The outlet of pull-out spray incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2201351
Size:
Stainless-steel braided PEX line flexible hose assemblies incorporating ½” BSP captive nut end connections
Marking:
Clearwater on body.
Installation Requirements:
R001 R009 R090
Expiry date:
31/01/2027
Model:
LEV20CP, LEV20BN, LEV20BB, LEV20MB, SAN20CP, SAN20BN, SAN20BB, SAN20MB, SAN20SS, KAR20CP, KAR20BN, KAR20BB, KAR20MB & KAR20SS Kitchen mixer
Product Images

Approval Holder:
Clearwater Products Limited t/a Sterling
Company Name
Clearwater Products Limited t/a Sterling
Address
Shannon Place Tewkesbury Business Park Tewkesbury Gloucestershire
Postcode
GL20 8BB
Country
United Kingdom
Phone
0168429955

View All Listings by this Company

Print This Approval


#2201352

Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating ceramic disc headworks and single lever operating members. The cold inlet to the tap incorporates incorporates an approved check valve cartridge which has been verified by test (as suitable for backflow protection against Fluid Category 2). The inlet of hose to the pull-out spray incorporates an approved check valve cartridge which has not been fully tested to demonstrate it provides backflow protection. The outlet of pull-out spray incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2201352
Size:
Stainless steel braided, PEX lined flexible hose assemblies incorporating ½” captive nut end connections.
Marking:
Clearwater on body
Installation Requirements:
R001 R009 R010 R090
Expiry date:
31/01/2027
Model:
KIR20CP, KIR20BN, KIR30CP, KIR30BN, KIR30BB, KIR30MB, TOP30BN, TOP30BB & TOP30MB
Product Images

Approval Holder:
Clearwater Products Limited t/a Sterling
Company Name
Clearwater Products Limited t/a Sterling
Address
Shannon Place Tewkesbury Business Park Tewkesbury Gloucestershire
Postcode
GL20 8BB
Country
United Kingdom
Phone
0168429955

View All Listings by this Company

Print This Approval


#2209014

Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating a ceramic cartridge headworks with single lever operating members and a pull-out spray spout. The outlet incorporates a plastic aerator and single check valve cartridge however the product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2209014
Size:
Stainless steel braided, silicone lined flexible hose assembly with 3/8" BSP captive nuts
Marking:
FIMA| Carlo Frattini on operating member
Installation Requirements:
R001 R009 R090
Expiry date:
30/09/2027
Model:
F3538N.S.WR F3538N.WR F3538NM.S.WR F3538NM.WR

Approval Holder:
Fima Carlo Frattini SPA
Company Name
Fima Carlo Frattini SPA
Country
Italy
Phone
0039 0322 9549

View All Listings by this Company
Manufacturer:
Fima Carlo Frattini SPA
Company Name
Fima Carlo Frattini SPA
Country
Italy
Phone
0039 0322 9549

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 9 of 16

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.