Section Code 0684 : Tap with a non-touch methods of flow control and a single inlet. Products listed in this section utilise flow control methods that do not require touch to activate.
Back To Directory SectionsA range of deck mounted, single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass). The flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. These products are supplied with an inline servicing valve integrated with a strainer and single check valve assemblies that has been verified by test for back flow prevention level 2. Maximum working pressure 10 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) electronically controlled combination tap assembles with brass bodies (various finishes). Flow is controlled via a solenoid valve activated via an infra -red sensor. The temperature is controlled via a ceramic cartridge and a single lever operating member. The inlet adaptor incorporates a single check valve cartridge (verified by test, suitable for backflow protection against fluid category 2). The outlet incorporates a stainless-steel strainer and an aerator. Maximum working pressure 5.0 bar Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) electronically controlled combination tap assembles with brass bodies (various finishes). Flow is controlled via a solenoid valve activated via an infra -red sensor. The temperature is controlled via a ceramic cartridge and a single lever operating member. The spout outlet incorporates a pull-out spray with a plastic aerator. The trigger on the pull-out controls optional spray. The inlet adaptor incorporates a single check valve cartridge (verified by test, suitable for backflow protection against fluid category 2). The outlet incorporates a stainless-steel strainer and an aerator. Maximum working pressure 5.0 bar Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) electronically controlled tap assemblies (chrome plated brass finish). The flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator and a stainless-steel strainer on the inlet. Maximum working pressure 8.0 Bar Maximum operating temperature 70.0°C
Range of electronically controlled taps (chromium plated brass). The assemblies incorporate a touch sensitive device and are supplied with a solenoid valve to control the flow. Spout outlet incorporates a plastic aerator and the product is supplied with stainless steel strainers. Maximum working pressure 8.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (fixed) electronically controlled tap assemblies (chrome plated brass finish). The flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator and a stainless-steel strainer on the inlet. Maximum working pressure 8.0 Bar Maximum operating temperature 70.0°C
Range of single hole, single outlet (fixed) electronically controlled combination tap assembles with brass bodies (various finishes). Flow is controlled via a solenoid valve activated via an infra -red sensor. The temperature is controlled via a ceramic cartridge and a single lever operating member. The spout outlet incorporates a pull-out spray with a plastic aerator. The trigger on the pull-out controls optional spray. The inlet adaptor incorporates a single check valve cartridge (verified by test, suitable for backflow protection against fluid category 2). The outlet incorporates a stainless-steel strainer and an aerator. Maximum working pressure 5.0 bar Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) with a pull-out spray mechanism. Flow is controlled via a ceramic cartridge headwork with a single lever operating member incorporating an infra-red sensor on the swivel arm which operates a solenoid valve. The spout outlet incorporates a plastic aerator and a hand spray mechanism, and the product is supplied with metal backnuts. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of wall mounted, single hole, single outlet (fixed) electronically controlled combination tap assemblies (brushed stainless steel). The flow is controlled by a solenoid valve activated via an infra-red sensor. The inlet to the solenoid incorporates a stainless-steel strainer. The spout outlet incorporates a plastic aerator. The products are supplied with plastic backnuts and a stainless steel braided PEX lined flexible hose assembly for installation between the tap and the solenoid valve. The HK-Cha models added September are also supplied with a plastic flow regulator. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) electronically controlled tap assemblies (chrome plated brass). Flow is controlled by a solenoid valve activated via an infra-red sensor. Models are either cold/premixed water only or hot and cold supply with a manually adjustable temperature lever. The product incorporates stainless steel strainers and the inlets incorporate approved check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 70°C.
Page 6 of 14
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.