TEST SITE

Combination Tap Assemblies

Section Code 0470 : Single hole tap with a single outlet and a swivel spout. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.

Back To Directory Sections

#2209308

Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork and single lever operating member.The spout outlet incorporates a plastic aerator Maximum working pressure 10.0 bar. Maximum operating temperature 60°C

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole tap with a single outlet and a swivel spout. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2209308
Size:
Polyamide braided PEX lined flexible hose assemblies incorporating 3/8” BSP captive nut end connections
Marking:
Grohe on operating member. Grohe and other technical information on rear of body.
Installation Requirements:
R001 R006 R009 R010
Expiry date:
30/09/2027
Model:
33281003, 33281DC3, 32441002, 30465000 & 30465DC0
Product Images

Approval Holder:
Grohe AG
Company Name
Grohe AG
Address
Industriepark Edelburg, 58675 Hemer
Country
Germany
Phone
02372 930
General Email
info@grohe.com

View All Listings by this Company
Manufacturer:
Grohe AG
Company Name
Grohe AG
Address
Industriepark Edelburg, 58675 Hemer
Country
Germany
Phone
02372 930
General Email
info@grohe.com

View All Listings by this Company

Print This Approval


#2209046

Range single hole, single outlet swivel combination tap assemblies (brushed stainless steel) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole tap with a single outlet and a swivel spout. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2209046
Size:
Stainless steel braided, PEX lined flexible hose assemblies incorporating 1/2" BSP captive nut end connections.
Marking:
Blanco on base of body
Installation Requirements:
R001 R006 R009 R010
Expiry date:
30/09/2027
Model:
526703 Blanco Candor Twin. 526704 Blanco Jandora Twin. 526702 Blanco Lanora Twin
Product Images

Approval Holder:
Blanco GMBH & Co Kg
Company Name
Blanco GMBH & Co Kg
Address
Flehinger Str 59 75038 Oberderdingen Germany

View All Listings by this Company

Print This Approval


#2209319

Single hole, single outlet (swivel) combination tap assembly (chrome plated brass body). Incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator or flow straightener with a stainless steel and EPDM strainer. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole tap with a single outlet and a swivel spout. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2209319
Size:
Stainless steel braided EPDM lined flexible hoses with ½” BSP (F) captive nut end connections.
Marking:
Francis Pegler on body
Installation Requirements:
R001 R006 R010
Expiry date:
30/09/2027
Model:
4S1209
Product Images

Approval Holder:
StH Westco Ltd
Company Name
StH Westco Ltd
Address
Unit C6 William Way Moss Industrial Estate St Helens Road Leigh
Postcode
WN7 3PT
Country
United Kingdom
Phone
01942 265230

View All Listings by this Company

Print This Approval


#2203375

Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The cold water inlet incorporate an approved check valve cartridge, verified by test (as suitable for backflow protection against Fluid Category 2) The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole tap with a single outlet and a swivel spout. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2203375
Size:
Stainless-steel braided PEX lined flexible hose assemblies incorporating ½” captive nut end connections
Marking:
Clearwater on body.
Installation Requirements:
R001 R006 R009 R010
Expiry date:
31/03/2027
Model:
LEV10CP, LEV10BN, LEV10BB & LEV10MB
Product Images

Approval Holder:
Clearwater Products Limited t/a Sterling
Company Name
Clearwater Products Limited t/a Sterling
Address
Shannon Place Tewkesbury Business Park Tewkesbury Gloucestershire
Postcode
GL20 8BB
Country
United Kingdom
Phone
0168429955

View All Listings by this Company

Print This Approval


#2204360

Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) incorporating quarter turn ceramic disk headworks with single lever operating members. The cold water inlets is supplied with a chrome plated brass adapter incorporating an approved check valve cartridge which has been verified by test (as suitable for backflow protection against Fluid Category 2) The spout outlets incorporate plastic aerators. Maximum working pressure 5 bar. Maximum operating temperature 60°C.

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole tap with a single outlet and a swivel spout. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2204360
Size:
Stainless-steel braided PEX lined flexible hoses with ½” BSP (F) captive nut end connections.
Marking:
Clearwater on tap body
Installation Requirements:
R001 R006 R009 R010
Expiry date:
30/04/2027
Model:
KIR10CP, KIR10BN, KIR10BB, KIR10MB, TOP10BN, TOP10BB, TOP10MB, TOP20BN, TOP20BB, TOP20MB, SAN10CP, SAN10BN, SAN10BB, SAN10MB, SAN10SS, KAR10CP, KAR10BN, KAR10BB, KAR10MB & KAR10SS COMBINATION TAP ASSEMBLIES
Product Images

Approval Holder:
Clearwater Products Limited t/a Sterling
Company Name
Clearwater Products Limited t/a Sterling
Address
Shannon Place Tewkesbury Business Park Tewkesbury Gloucestershire
Postcode
GL20 8BB
Country
United Kingdom
Phone
0168429955

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 47 of 70

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.