Section Code 0445 : Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.

Back To Directory Sections

#2201321

Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating ceramic disc headworks and single lever operating members. The cold inlet to the tap incorporates incorporates an approved check valve cartridge which has been verified by test (as suitable for backflow protection against Fluid Category 2). The inlet of hose to the pull-out spray incorporates an approved check valve cartridge which has not been fully tested to demonstrate it provides backflow protection. The outlet of pull-out spray incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2201321
Size:
Stainless steel braided, PEX lined flexible hose assemblies incorporating ½” captive nut end connections.
Marking:
Lota on body
Installation Requirements:
R001 R009 R010 R090
Expiry date:
31/01/2027
Model:
63433-00X 63433-01X 63433-03X X denotes finish and can be replaced with: 01 - Chrome 04 - Brushed Nickel 08 - Stainless steel 4408 - Brushed Brass 6801 - Matt Black 5804 - Heirloom Silver 0402 - Brushed Nickel PVD
Product Images

Approval Holder:
Xiamen Lota International Co., Ltd.
Company Name
Xiamen Lota International Co., Ltd.
Address
No.61 Xingnan Road, Jimei District, Xiamen, 361022
Country
China
Phone
86-592-6665866

View All Listings by this Company
Manufacturer:
Xiamen Lota International Co., Ltd.
Company Name
Xiamen Lota International Co., Ltd.
Address
No.61 Xingnan Road, Jimei District, Xiamen, 361022
Country
China
Phone
86-592-6665866

View All Listings by this Company

Print This Approval


#2201328

Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating ceramic disc headworks and single lever operating members. The cold inlet to the tap incorporates incorporates an approved check valve cartridge which has been verified by test (as suitable for backflow protection against Fluid Category 2). The inlet of hose to the pull-out spray incorporates an approved check valve cartridge which has not been fully tested to demonstrate it provides backflow protection. The outlet of pull-out spray incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2201328
Size:
Stainless-steel braided PEX line flexible hose assemblies incorporating ½” BSP captive nut end connections.
Marking:
Lota on body.
Installation Requirements:
R001 R009 R010 R090
Expiry date:
31/01/2027
Model:
63435-00X Pull out Kitchen mixer 63437-01X Pull out Kitchen mixer 63442-00X Pull out Kitchen mixer 63440-00X Kitchen mixer 63440-01X Kitchen mixer X denotes finish and can be replaced: 01 - Chrome 04 - Brushed Nickel 08 - Stainless steel 4408 - Brushed Brass 6801 - Matt Black 5804 - Heirloom Silver 0402 - Brushed Nickel PVD
Product Images

Approval Holder:
Xiamen Lota International Co., Ltd.
Company Name
Xiamen Lota International Co., Ltd.
Address
No.61 Xingnan Road, Jimei District, Xiamen, 361022
Country
China
Phone
86-592-6665866

View All Listings by this Company
Manufacturer:
Xiamen Lota International Co., Ltd.
Company Name
Xiamen Lota International Co., Ltd.
Address
No.61 Xingnan Road, Jimei District, Xiamen, 361022
Country
China
Phone
86-592-6665866

View All Listings by this Company

Print This Approval


#2201351

Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating ceramic disc headworks and single lever operating members. The cold inlet to the tap incorporates incorporates an approved check valve cartridge which has been verified by test (as suitable for backflow protection against Fluid Category 2). The inlet of hose to the pull-out spray incorporates an approved check valve cartridge which has not been fully tested to demonstrate it provides backflow protection. The outlet of pull-out spray incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2201351
Size:
Stainless-steel braided PEX line flexible hose assemblies incorporating ½” BSP captive nut end connections
Marking:
Clearwater on body.
Installation Requirements:
R001 R009 R090
Expiry date:
31/01/2027
Model:
LEV20CP, LEV20BN, LEV20BB, LEV20MB, SAN20CP, SAN20BN, SAN20BB, SAN20MB, SAN20SS, KAR20CP, KAR20BN, KAR20BB, KAR20MB & KAR20SS Kitchen mixer
Product Images

Approval Holder:
Clearwater Products Limited t/a Sterling
Company Name
Clearwater Products Limited t/a Sterling
Address
Shannon Place Tewkesbury Business Park Tewkesbury Gloucestershire
Postcode
GL20 8BB
Country
United Kingdom
Phone
0168429955

View All Listings by this Company

Print This Approval


#2201352

Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating ceramic disc headworks and single lever operating members. The cold inlet to the tap incorporates incorporates an approved check valve cartridge which has been verified by test (as suitable for backflow protection against Fluid Category 2). The inlet of hose to the pull-out spray incorporates an approved check valve cartridge which has not been fully tested to demonstrate it provides backflow protection. The outlet of pull-out spray incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2201352
Size:
Stainless steel braided, PEX lined flexible hose assemblies incorporating ½” captive nut end connections.
Marking:
Clearwater on body
Installation Requirements:
R001 R009 R010 R090
Expiry date:
31/01/2027
Model:
KIR20CP, KIR20BN, KIR30CP, KIR30BN, KIR30BB, KIR30MB, TOP30BN, TOP30BB & TOP30MB
Product Images

Approval Holder:
Clearwater Products Limited t/a Sterling
Company Name
Clearwater Products Limited t/a Sterling
Address
Shannon Place Tewkesbury Business Park Tewkesbury Gloucestershire
Postcode
GL20 8BB
Country
United Kingdom
Phone
0168429955

View All Listings by this Company

Print This Approval


#2209014

Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating a ceramic cartridge headworks with single lever operating members and a pull-out spray spout. The outlet incorporates a plastic aerator and single check valve cartridge however the product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2209014
Size:
Stainless steel braided, silicone lined flexible hose assembly with 3/8" BSP captive nuts
Marking:
FIMA| Carlo Frattini on operating member
Installation Requirements:
R001 R009 R090
Expiry date:
30/09/2027
Model:
F3538N.S.WR F3538N.WR F3538NM.S.WR F3538NM.WR

Approval Holder:
Fima Carlo Frattini SPA
Company Name
Fima Carlo Frattini SPA
Country
Italy
Phone
0039 0322 9549

View All Listings by this Company
Manufacturer:
Fima Carlo Frattini SPA
Company Name
Fima Carlo Frattini SPA
Country
Italy
Phone
0039 0322 9549

View All Listings by this Company

Print This Approval


#2203376

Single-hole, single outlet (swivel) combination tap assembly with brass body (chrome plated), incorporating a ceramic cartridge headwork with a single lever operating member. The product has a pull-out spray outlet which incorporates a plastic aerator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection The cold inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2203376
Size:
Stainless-steel braided, EPDM lined flexible hose assemblies incorporating ½” captive nut end connections.
Marking:
Buster & Punch London on body
Installation Requirements:
R001 R010 R090
Expiry date:
31/03/2027
Model:
RKT-071664, RKT-351667, RKT-051665, RKT-591666, RKT-071660, RKT-361663, RKT-051661 & RKT-591662 COMBINATION TAP ASSEMBLIES
Product Images

Approval Holder:
Buster and Punch Ltd
Company Name
Buster and Punch Ltd
Address
29 St. Peters Street Stamford
Postcode
PE9 2PF

View All Listings by this Company

Print This Approval


#2209012

Range of single hole, single outlet (swivel) combination tap assemblies with pull-down hose. Incorporating a brass body (various finishes) and a ceramic cartridge headwork with single lever operating member. The spout outlet incorporates a plastic aerator and an approved single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2209012
Size:
Stainless steel braided flexible EPDM lined flexible hose assemblies with ½” BSP captive nuts.
Marking:
1810 on operating member.
Installation Requirements:
R001 R006 R010
Expiry date:
30/09/2027
Model:
SPI-KNR/01/CH - SPIRALE KNURLED CHROME SPI-KNR/02/BS - SPIRALE KNURLED BRUSHED STEEL SPI-KNR/04/COP - SPIRALE KNURLED COPPER SPI-KNR/05/GM - SPIRALE KNURLED GUNMETAL SPI-KNR/06/GB - SPIRALE KNURLED GOLD BRASS SPI-KNR/07/MB - SPIRALE KNURLED MATTE BLACK SPI-KNR/08/BGB - SPIRALE KNURLED BRUSHED GOLD BRASS SPI/01/CH - SPIRALE CHROME SPI/02/BS - SPIRALE BRUSHED STEEL SPI/04/COP - SPIRALE COPPER SPI/05/GM - SPIRALE GUNMETAL SPI/06/GB - SPIRALE GOLD BRASS SPI/07/MB - SPIRALE MATTE BLACK SPI/08/BGB - SPIRALE BRUSHED GOLD BRASS

Approval Holder:
The 1810 Company limited
Company Name
The 1810 Company limited
Address
Unit 14-16, Bromfield Industrial Estate, Queens Lane Mold
Postcode
CH7 1JR
Phone
0044 7772144600

View All Listings by this Company

Print This Approval


#2209062

Range of single hole, single outlet (swivel) combination tap assemblies with pull-down hose. Incorporating a brass body (various finishes) and a ceramic cartridge headwork with single lever operating member. The spout outlet incorporates a plastic aerator and an approved single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2209062
Size:
Stainless steel braided flexible EPDM lined flexible hose assemblies with ½” BSP captive nuts.
Marking:
1810 on operating member.
Installation Requirements:
R001 R010 R090
Expiry date:
30/09/2027
Model:
SPI-SPR/01/CH - SPIRALE SPRING CHROME SPI-SPR/02/BS - SPIRALE SPRING BRUSHED STEEL SPI-SPR/04/COP - SPIRALE SPRING COPPER SPI-SPR/05/GM - SPIRALE SPRING GUNMETAL SPI-SPR/06/GB - SPIRALE SPRING GOLD BRASS SPI-SPR/07/MB - SPIRALE SPRING MATTE BLACK SPI-SPR/08/BGB - SPIRALE SPRING BRUSHED GOLD BRASS

Approval Holder:
The 1810 Company limited
Company Name
The 1810 Company limited
Address
Unit 14-16, Bromfield Industrial Estate, Queens Lane Mold
Postcode
CH7 1JR
Phone
0044 7772144600

View All Listings by this Company

Print This Approval


#2207322

Single hole, single outlet (swivel) combination tap assembly (chrome plated brass) incorporating a ceramic cartridge headwork with single lever operating member and pull out spray handset. The spout outlet incorporates a plastic aerator. Maximum working pressure 5 bar. Maximum operating temperature 65°C

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2207322
Size:
Stainless steel braided EPDM lined flexible hose assemblies with ½” BSP (F) captive nut end connections.
Marking:
Deva on front of body. DTC25 on rear of body.
Installation Requirements:
R001 R090
Expiry date:
31/07/2027
Model:
PEN104 – Pendle pull out kitchen mixer
Product Images

Approval Holder:
Methven UK Limited
Company Name
Methven UK Limited
Address
3-3A Stone Cross Court, Yew Tree Way, Golborne, Warrington
Postcode
WA3 3JE
Country
United Kingdom
Phone
0800 195 1602

View All Listings by this Company

Print This Approval


#2212704

Range of single hole, single outlet (swivel) combination tap assemblies (chrome plated brass bodies), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet are pull-out spray type, which incorporates aerators and approved single check valve cartridges, however the complete assemblies have not been tested to demonstrate backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 65.°C

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2212704
Size:
Stainless steel braided EPDM lined flexible hoses with 1/2" BSP captive nuts 15mm compression inlet adapter on stainless Steel braided EPDM lined flexible hoses – Model M9604T
Marking:
PPI on tap body.
Installation Requirements:
R001 R090
Expiry date:
31/12/2027
Model:
167028 907013 M9604T

Approval Holder:
PPI Xiamen Industry Co Ltd
Company Name
PPI Xiamen Industry Co Ltd
Address
No 88 South Houxiang Road Xinyang Industrial Zone Haicang District Xiamen 361022
Country
China

View All Listings by this Company
Manufacturer:
PPI Xiamen Industry Co Ltd
Company Name
PPI Xiamen Industry Co Ltd
Address
No 88 South Houxiang Road Xinyang Industrial Zone Haicang District Xiamen 361022
Country
China

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 5 of 8

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.