Section Code 0470 : Single hole tap with a single outlet and a swivel spout. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
Back To Directory SectionsRange of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate a plastic aerator. The 32 082 xxx model is supplied with a click type waste, the 32 084 xxx & 71 130 xxx models have a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (swivel) combination tap assemblies brass bodies (various finishes, see model), incorporating quarter turn ceramic disk headworks with single lever operating members. The spout outlet incorporates a plastic aerator. The product is supplied with an approved fixing kit that incorporates isolation valves with single check valve assemblies (verified by test - suitable for backflow protection against fluid Category 2). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with dome type operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chrome plated brass), incorporating quarter turn ceramic disc headworks. The inlet hose assemblies incorporate a servicing valve and is supplied with a single check valve assembly verified by test (suitable for backflow protection against Fluid Category 2). The spout outlets incorporate a plastic aerator. Maximum working pressure 10.00 bar. Maximum operating temperature 60°C.
Page 39 of 70
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.