TEST SITE

Heat Exchangers

Section Code 1350 :

Back To Directory Sections

#2204319

Range of plate heat exchanger with stainless steel bodies. Maximum working pressure10 bar. Maximum operating temperature 100°C.

Section:
1350 Heat Exchangers
Size:
½”BSP(M) secondary x ¾”BSP(M) primary Ø 16mm holes on inlets and outlets
Marking:
G20 Engineering logo, model number, production date WW/YY etched on body
Installation Requirements:
R001
Expiry date:
30/04/2027
Model:
Plate heat exchanger – Type PEP15440A01 (with insert M5) PEP15440A01-20 PEP15440A01-18 PEP15440A01-16 PEP15440A01-14 PEP15440A01-12 PEP15440A01-10 Plate heat exchanger – Type PEP15440B01 (with 2 G ½’ fitting and 2 G ¾’ fitting) PEP15440B01-20 PEP15440B01-18 PEP15440B01-16 PEP15440B01-14 PEP15440B01-12 PEP15440B01-10
Product Images

Approval Holder:
G20 ENGINEERING s.r.l.
Company Name
G20 ENGINEERING s.r.l.
Address
Localita Campogrande 13- 29013 Carpaneto P.no (PC)
Country
Italy

View All Listings by this Company

Print This Approval


#2204326

‘POD’ range of indirect and direct heat interface units providing space heating and instantaneous hot water. The heat transfer is generated via plate heat exchangers. The domestic hot water (DHW) circuit incorporates an adjustable temperature mixing valve. The indirect models incorporate an expansion vessel (on the CW inlet of the DHW circuit) and a pressure relief valve set at 3.0 bar (on the space heating circuit). The indirect models only are supplied with a temporary filling loop, which comprises of a stainless steel braided EPDM lined flexible hose assembly and a lever operated spherical valve for connection to the primary circuit. The angled cold water inlet incorporates an isolation valve and a branch to connect to the filling loop, which includes a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3). Maximum working pressure for indirect units: Primary circuit: 16.0 bar. Space heating: 2.5 bar. Secondary circuit (DHW): 10.0 bar. Maximum working pressure for direct units: Primary circuit: 10.0 bar. Space heating: 10.0 bar. Secondary circuit (DHW): 10.0 bar. Maximum operating temperature for domestic hot water 65°C. Maximum operating temperature for central heating and primary circuit 85°C.

Section:
1350 Heat Exchangers
Size:
22mm copper pipe connection.
Marking:
Ideal Heating badge and model on adhesive label on front casing. Manufacturer, serial number, model number, pressure rating and other technical information on data label within appliance.
Installation Requirements:
R001 R140 R360
Expiry date:
30/04/2027
Model:
POD range of indirect (i prefix) and direct (d prefix) HIU: i305, i405, i505, i605, i705, d30, d40, d50, d60. All models can have the following suffixes to denote the inclusion of a heat meter: HWM for a hard wired MBUS and WLM for a wireless MBUS.
Product Images

Approval Holder:
Ideal Heating.Limited
Company Name
Ideal Heating.Limited
Address
Po Box 103 National Avenue Kingston Upon Hull Humberside
Postcode
HU5 4JN

View All Listings by this Company
Manufacturer:
Ideal Heating.Limited
Company Name
Ideal Heating.Limited
Address
Po Box 103 National Avenue Kingston Upon Hull Humberside
Postcode
HU5 4JN

View All Listings by this Company

Print This Approval


#2204062

Range of stainless-steel plate heat exchangers. Maximum operating pressures - primary circuit: 3.0 bar, secondary circuit (DHW): 10.0.bar. Maximum working temperature 80°C.

Section:
1350 Heat Exchangers
Size:
Ø 15.6mm holes on inlets and outlets
Marking:
Condevo, model name, date of manufacture (DDMMYY) on adhesive label on body
Installation Requirements:
R001
Expiry date:
30/04/2027
Model:
Type ‘H’ range of Heat Exchangers: PPAAFHBCDE Where: PP = Product plates, AA = Number of plates in multiples of 2, ranging from 10 to 34 plates, FH = Model of plates and flow, B = Material type of exchange plates - 4 = AISI304L or 6 = AISI316L, C = Coupling plate - T or R to denote hole distance option, DE = Configuration - position of studs and/or position of label (indicates configuration: progressive) - can be any 2 digit number or alphanumeric combination.
Product Images

Approval Holder:
Condevo SpA
Company Name
Condevo SpA
Address
Via Luna, Z.A. 26866 Marudo (LO) Italy

View All Listings by this Company
Manufacturer:
Condevo SpA
Company Name
Condevo SpA
Address
Via Luna, Z.A. 26866 Marudo (LO) Italy

View All Listings by this Company

Print This Approval


#2206361

Range of heat exchangers connected to copper waste pipe, Where the waste is discharged down a “rotator” into a copper waste pipe, and potable water is returned to the shower/heating device via a copper double walled jacket around the copper waste pipe. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C

Section:
1350 Heat Exchangers
Size:
½” BSP (F)
Marking:
Manufacturer ( Builidng Product Distribution) Manufacturer address Type Category BPD Ltd Serial No. Model & other information on Adhesive label.
Installation Requirements:
R001
Expiry date:
30/06/2027
Model:
Showersave: QB1-21C QB1-16C QB1-12C QB1-21 Cyclone QB1-21 QB1-16 QB1-12 QB1-21D QB1-21D HE
Product Images

Approval Holder:
BPD Limited
Company Name
BPD Limited
Address

View All Listings by this Company

Print This Approval


#2207023

Range of cross and parallel flow water plate heat exchangers with stainless steel bodies. Maximum working pressure primary circuit: 3.0 bar, secondary circuit: 10.0 bar. Maximum operating temperature 80°C.

Section:
1350 Heat Exchangers
Size:
15.7mm ID
Marking:
CONDEVO SpA, model and date of manufacture (DD/MM/YY) on label on body.
Installation Requirements:
R001
Expiry date:
31/07/2027
Model:
Type “W” range of cross and parallel flow heat exchangers, model code is as follows: PP aaFWywRxx. Where: aa = number of plates (from 10 to 34 plates). F = parallel flow. W = identifies shape of plates. y = type of stainless steel, 4 for AISI304L and 6 for AISI316L w = type of coupling plate R (distance between holes 42mm), Q (only for crossed flow) Rxx = coupling plate with xx replaced with numbers denoting distance between holes.
Product Images

Approval Holder:
Condevo SpA
Company Name
Condevo SpA
Address
Via Luna, Z.A. 26866 Marudo (LO) Italy

View All Listings by this Company
Manufacturer:
Condevo SpA
Company Name
Condevo SpA
Address
Via Luna, Z.A. 26866 Marudo (LO) Italy

View All Listings by this Company

Print This Approval


#2210032

Range of plate heat exchangers with stainless steel plates, for primary and secondary circulation. Models E040-2M-GB6 and R040-H2M-G6B are secondary use only. Maximum working pressure - R040-HNM-G6B range = 30.0 Bar and E040-NM-GB6 range = 20.0 Bar Maximum operating temperature - 99 °C

Section:
1350 Heat Exchangers
Size:
3/4" BSP Male
Marking:
Kaori Logo, Model, Max Pressure & Max Temp on Adhesive Label on Body. Model on Top Plate.
Installation Requirements:
R001
Expiry date:
31/10/2027
Model:
R040-HNM-G6B - “N” = Number of plates 2-40 plates E040-NM-GB6 - “N” = Number of plates 2-60 plates

Approval Holder:
Kaori Heat Treatment Co., Ltd
Company Name
Kaori Heat Treatment Co., Ltd
Address
No 5-2 Chi Lin North Road Chung Li District 320030

View All Listings by this Company
Manufacturer:
Kaori Heat Treatment Co., Ltd
Company Name
Kaori Heat Treatment Co., Ltd
Address
No 5-2 Chi Lin North Road Chung Li District 320030

View All Listings by this Company

Print This Approval


#2210054

Alfa Laval range of copper brazed and stainless-steel fusion bonded, stainless steel heat exchangers in various sizes ranging from 4 plates to 300 plates. Maximum working pressures and temperatures: CB10, CB11, CB15, CB16, CB16AQ, CB18, CB18AQ & CB18DW: S1/S2 circuit: 5 Bar. S3/S4 circuit 10 Bar. Max working temperature 150°C. CB20 & CB20AQ: S1/S2 circuit: 16 Bar. S3/S4 circuit 16 Bar. Max working temperature 225°C. CB65, CB65AQ & CBH65: S1/S2 circuit: 18 Bar. S3/S4 circuit 37 Bar. Max working temperature 225°C. CBH16 & CBH18: S1/S2 circuit: 32 Bar. S3/S4 circuit 32 Bar. Max working temperature 150°C. Maximum operating temperatures detailed above are for primary circuits only, secondary circuits approved to 99oC. Models added March 2023: CBH30: 50 Bar (S1/S2/S3/S4) & 225.0°C, CBH112: 45 Bar (S1/S2) 51 Bar (S3/S4) & 225.0°C, CB30: 41 Bar (S1/S2/S3/S4) & 225.0°C, CB60: 40 Bar (S1/S2/S3/S4) & 225.0°C, CB60AQ: 40 Bar (S1/S2/S3/S4) & 225.0°C, CBH60: 40 Bar (S1/S2/S3/S4) & 225.0°C, CB62: 40 Bar (S1/S2/S3/S4) & 225.0°C, CB62AQ: 40 Bar (S1/S2/S3/S4) & 225.0°C, CBH62: 40 Bar (S1/S2/S3/S4) & 225.0°C, CB30AQ: 40 Bar (S1/S2/S3/S4) & 225.0°C, CB110: 37 Bar (S1/S2/S3/S4) & 225.0°C, CB110AQ: 37 Bar (S1/S2/S3/S4) & 225.0°C, CBH110: 37 Bar (S1/S2/S3/S4) & 225.0°C, CB112: 37 Bar (S1/S2/S3/S4) & 225.0°C, CB112AQ: 37 Bar (S1/S2/S3/S4) & 225.0°C, CB24: 29 Bar (S1/S2) 37 Bar (S3/S4) & 225.0°C, CB24AQ: 29 Bar (S1/S2) 37 Bar (S3/S4) & 225.0°C, ANTW66: 29.0 Bar (S1/S2/S3/S4), ANTW18: 23 Bar (S1/S2) 28 Bar (S3/S4) 225.0°C and RM11: 15 Bar (S3/S4) & 225.0°C. Maximum operating temperatures detailed above are for primary circuits only, secondary circuits approved to 99oC.

Section:
1350 Heat Exchangers
Size:
See Models
Marking:
CB10, CB15, CB16, CB18 models: Manufacturers logo, model number and technical information on label on from of heat exchanger. CB20 and CB65 models: Manufacturers logo, model number, serial number, manufacturing date (yyyy.mm.dd), minimum and maximum working temperature, minimum and maximum working pressure and technical information on label on front of heat exchanger. Models added March 2023: Alfa Laval logo, Model, serial number on adhesive label.
Installation Requirements:
R001
Expiry date:
31/10/2027
Model:
CB10: Minimum number of plates 4, Maximum number of plates 60. Connection Size/types: None O-ring, ¾” or 1” Male BSP connections or 12mm or 28mm soldered connections for use with copper tube conforming to EN 1057. CB11: Minimum number of plates 8, Maximum number of plates 60. Connection Size/types: None O-ring, ¾” or 1” Male BSP connections or 12mm or 28mm soldered connections for use with copper tube conforming to EN 1057. CB15: Minimum number of plates 4, Maximum number of plates 60. Connection Size/types: None O-ring, ¾” or 1” Male BSP connections or 12mm or 28mm soldered connections for use with copper tube conforming to EN 1057. CB16/CBH16: Minimum number of plates 4, Maximum number of plates 60. Connection Size/types: None O-ring, ¾” or 1” Male BSP connections or 12mm or 28mm soldered connections for use with copper tube conforming to EN 1057. CB16AQ: Minimum number of plates 4, Maximum number of plates 60. Connection Size/types: None O-ring, ¾” or 1” Male BSP connections. CB18/CBH18: Minimum number of plates 4, Maximum number of plates 52. Connection Size/types: None O-ring, ¾” or 1” Male BSP connections or 12mm or 28mm soldered connections for use with copper tube conforming to EN 1057. CB18AQ: Minimum number of plates 4, Maximum number of plates 60. Connection Size/types: None O-ring, ¾” or 1” Male BSP connections. CB18DW: Minimum number of plates 4, Maximum number of plates 52. Connection Size/types: None O-ring, ¾” or 1” Male BSP connections or 12mm or 28mm soldered connections for use with copper tube conforming to EN 1057. CB20: Minimum number of plates 10, Maximum number of plates 110. Connection types: External thread or soldered. Connection Size/types: ¾” or 1” Male BSP connections or 12mm or 28mm soldered connections for use with copper tube conforming to EN 1057. CB20AQ: Minimum number of plates 10, Maximum number of plates 110. Connection Size/types: ¾” or 1” Male BSP connections. CB65/CBH65: Minimum number of plates 10, Maximum number of plates 150. Connection types: External thread or soldered. Connection Size/types: ¾” or 1” Male BSP connections or 12mm or 28mm soldered connections for use with copper tube conforming to EN 1057. CB65AQ: Minimum number of plates 10, Maximum number of plates 150. Connection Size/types: ¾” or 1” Male BSP connections Models added March 2023: CB30: Minimum number of plates 10, Maximum number of plates 150. Connection Size/types: ¾” - 2” BSP M. CB30AQ: Minimum number of plates 10, Maximum number of plates 150. Connection Size/types: ¾” - 2” BSP M. CBH30: Minimum number of plates 10, Maximum number of plates 150. Connection Size/types: ¾” - 2” BSP M. CB60: Minimum number of plates 10, Maximum number of plates 150. Connection Size/types: ¾” - 2” BSP M. CB60AQ: Minimum number of plates 10, Maximum number of plates 150. Connection Size/types: ¾” - 2” BSP M. CBH60: Minimum number of plates 10, Maximum number of plates 150. Connection Size/types: ¾” - 2” BSP M. CB62: Minimum number of plates 10, Maximum number of plates 150. Connection Size/types: ¾” - 2” BSP M. CB62AQ: Minimum number of plates 10, Maximum number of plates 150. Connection Size/types: ¾” - 2” BSP M. CBH62: Minimum number of plates 10, Maximum number of plates 150. Connection Size/types: ¾” - 2” BSP M. CB110: Minimum number of plates 10, Maximum number of plates 300. Connection Size/types: ¾” - 2” BSP M. CB110AQ: Minimum number of plates 10, Maximum number of plates 300. Connection Size/types: ¾” - 2” BSP M. CBH110: Minimum number of plates 10, Maximum number of plates 300. Connection Size/types: ¾” - 2” BSP M. CB112: Minimum number of plates 10, Maximum number of plates 300. Connection Size/types: ¾” - 2” BSP M. CB112AQ: Minimum number of plates 10, Maximum number of plates 300. Connection Size/types: ¾” - 2” BSP M. CBH112: Minimum number of plates 10, Maximum number of plates 300. Connection Size/types: ¾” - 2” BSP M. RM11: Minimum number of plates 28, Maximum number of plates 28. Connection Size/types: 22mm ID - soldered connection for use with copper tube conforming to EN 1057. CB24: Minimum number of plates 10, Maximum number of plates 56. Connection Size/types: ¾” - 2” BSP M. ANTW18: Minimum number of plates 10, Maximum number of plates 50. Connection Size/types: ¾” - 2” BSP M. ANTW66: Minimum number of plates 10, Maximum number of plates 150. Connection Size/types: ¾” - 2” BSP M.

Approval Holder:
Alfa Laval Ltd
Company Name
Alfa Laval Ltd
Address
Doman Road Camberley Surrey
Postcode
GU15 3DN

View All Listings by this Company

Print This Approval


#2212802

Range of plate heat exchangers with stainless steel bodies. Model B8LAS has a maximum working pressure of 45.0 bar. Model 85-M has a maximum working pressure of 46/32 bar. Model E5P has a maximum working pressure of 10.0 bar. Maximum operating temperature 100°C.

Section:
1350 Heat Exchangers
Size:
Please refer to model.
Marking:
SWEP, model, temperature and pressure on adhesive label on body.
Installation Requirements:
R001
Expiry date:
31/12/2027
Model:
B8LAS (product name B8LAS-SC-M): Connection types: ½” - ¾” BSP, 4 to 70 plates. From April 2023 the B8LAS range is available with 'no connections'. 85-M (product name 85-SC-M): Connection types ½” - 1½”, 4 to 160 plates. From April 2023 the B8LAS range is available with 'no connections'. E5P (product name E5P-NSC-S): No connections, 8 to 40 plates.

Approval Holder:
SWEP International AB/SWEP Slovakia s.r.o.
Company Name
SWEP International AB/SWEP Slovakia s.r.o.
Address
Box 105, 26122, Landskrona
Country
Sweden
Phone
+46 418400406

View All Listings by this Company
Manufacturer:
SWEP International AB/SWEP Slovakia s.r.o.
Company Name
SWEP International AB/SWEP Slovakia s.r.o.
Address
Box 105, 26122, Landskrona
Country
Sweden
Phone
+46 418400406

View All Listings by this Company

Print This Approval


#2007391

Range of modular combined heating interface units providing a combination of either hot water, heating or cooling via a plate heat exchanger depending on model options. Heating and cooling circuits incorporate a safety relief valve (set at 3 bar) and expansion vessel and inlet connection can be either top or bottom entry configuration. Maximum working pressure 16 bar (primary, CWS and HWS) 2.5 bar on heating circuit. Maximum operating temperature 85°C.

Section:
1350 Heat Exchangers
Size:
See model.
Marking:
ElCO & NEXUS ECOON LABEL INSIDE BOILER ElCO PRINTED ON FRONT COVER
Installation Requirements:
R001
Expiry date:
31/07/2025
Proviso:
The filling loop supplied must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
Nexus S-Therm Eco t ¾” BSP (M) Nexus BiTherm Eco ¾” BSP(M)

Approval Holder:
Elco Heating Solutions Limited
Company Name
Elco Heating Solutions Limited
Address
Juniper West, 3 Fenton Way Southshields Business Park Basildon
Postcode
SS15 6SJ
Country
Essex
Phone
01268 546 700
General Email
enquiries@elco.co.uk

View All Listings by this Company

Print This Approval


#2305052

Range of stainless-steel plate heat exchanger assemblies incorporating single or twin pumps on the primary circuit. Maximum working pressure 10 Bar (UKE-8 models) or 6 bar (UKE-14 models).

Non-metallic materials and components comply with BS6920 at 85°C

Section:
1350 Heat Exchangers
Size:
UKE-8 range: Secondary circuit: 1¼” BSP (M) inlet/outlet, Primary circuit: 1¼” BSP (F) inlet/outlet. UKE-14 range: Secondary circuit: 2” BSP (M) inlet/outlet, Primary circuit: DN40 or DN50 flange inlet/outlet.
Marking:
UK Exchangers, Model no, Serial number, pressure, max temperature, manufacture date (YYYY) on data plate on body.
Installation Requirements:
R001
Expiry date:
31/05/2028
Model:
UKE-8-YY-XX (8 – 75 plates), UKE-14-YY-XX (8-70 plates). YY denotes number of ports, XX denotes number of plates.

Approval Holder:
UK Exchangers Ltd.
Company Name
UK Exchangers Ltd.
Address
Unit 55 Stilebrook Road Olney
Postcode
MK46 5EA
Country
Buckinghamshire

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 4 of 5

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.