Section Code 2035 : Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
Back To Directory SectionsRange of concealed WC cistern in white plastic incorporating a BS 1212-4:2016 side entry float operated inlet valve providing a Type AG air gap arrangement and a single or dual flush outlet valve. The full flush can be set at 6 litres and the reduced flush can be set at 3 litres. The inlet supply incorporates a servicing valve. Maximum operating pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush pneumatic outlet valve. The cistern incorporates an angled servicing valve and a stainless-steel braided EPDM lined flexible hose assembly installed prior to the inlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. Maximum working pressure 10.0 bar. Cold water use only.
AQUAECO RANGE OF WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
AQUAECO WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
AQUAECO WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Page 4 of 15
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.