Section Code 0445 : Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
Back To Directory SectionsSingle hole, single outlet (swivel) combination tap assembly with brass bodies (chrome plated), incorporating a ceramic cartridge headwork with single lever operating members. The product incorporates a pull-out spray with a plastic aerator at the outlet. The pull-out spray hose incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Range of single hole, single outlet (swivel) pull down spray combination tap assemblies (brass bodies - various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The connection between the body and the spout incorporates an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The outlet incorporates a plastic aerator. The products are supplied with optional ½” BSP (F) x ⅜ BSP (M) brass adaptors and NBR washers for installation on each inlet hose. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of four-hole, single outlet (swivel) combination tap assemblies (brass bodies, chrome plated or brushed steel finish) with a spout outlet and flexible hand spray outlet. The hot water is controlled to the spout outlet only (not to the spray outlet) via a quarter turn ceramic disc headwork with single lever operating member. The cold water to the spout outlet and trigger-operated spray outlet is controlled and diverted via a ceramic disc diverter headwork. The product is supplied with Stainless steel braided EPDM lined flexible hose assemblies for connection between the headworks and spout. The spout outlet incorporates a plastic aerator and the products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (brass bodies - various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The product incorporates a pull-down spout with a plastic aerator, which also incorporates an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with optional ⅜” BSP (M) x ½” BSP (F) adaptors each with two fibre gaskets for installation on each inlet hose. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single-hole, single outlet (swivel) combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a pull-out spray with a plastic aerator. Both inlet adaptor connections and the hand-spray inlet incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate that they provide back flow protection. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Single-hole, single outlet (swivel) combination tap assembly with brass body (chrome plated), incorporating a ceramic cartridge headwork with a single lever operating member. The product has a pull-out spray outlet which incorporates a plastic aerator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection The cold inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly, (Chrome plated) brass body incorporating a ceramic cartridge headwork with a single lever operating member. The product incorporates a pull out spray. The cold inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole single outlet (swivel) pull out spray combination tap assembly (chromium plated brass) with ¼ turn ceramic disc headwork and single lever operating members. The spout outlet incorporates a plastic flow aerator and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Two-hole, single outlet combination tap assembly with stainless steel body incorporating a ceramic cartridge headworks with lever operating members and a pull-out handset.. The spout inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates plastic aerator Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assemblies with brass body (chrome plated), incorporating a ceramic cartridge headworks with single leaver operating members. The spout outlet is a pull-down spray type incorporating a plastic aerator and a push button. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Page 4 of 8
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.