TEST SITE

Miscellaneous Fittings

Section Code 1530 :

Back To Directory Sections

#2305332

Range of wall unions with chrome plated brass bodies. Maximum operating temperature 60°C Open outlet use only

Non-metallic materials and components comply with BS6920 at 60°C

Section:
1530 Miscellaneous Fittings
Size:
½” BSP(M)
Marking:
Grohe on body
Installation Requirements:
R001 R040
Expiry date:
31/05/2028
Model:
28626000 28636000 28628000 28671000

Approval Holder:
Grohe AG
Company Name
Grohe AG
Address
Industriepark Edelburg, 58675 Hemer
Country
Germany
Phone
02372 930
General Email
info@grohe.com

View All Listings by this Company
Manufacturer:
Grohe AG
Company Name
Grohe AG
Address
Industriepark Edelburg, 58675 Hemer
Country
Germany
Phone
02372 930
General Email
info@grohe.com

View All Listings by this Company

Print This Approval


#2305912

Range of level and flow transmitters with plastic bodies. Maximum working pressure 3.0Bar

Non-metallic materials and components comply with BS6920 at 85°C

Section:
1530 Miscellaneous Fittings
Size:
1 ½” BSP (M) 1 ½” NPT (M)
Marking:
EMERSON Rosemount logo, model number and other technical information on body.
Installation Requirements:
R001
Expiry date:
31/05/2028
Model:
Rosemount 1208A Rosemount 1208C

Approval Holder:
Rosemount Tank Radar AB
Company Name
Rosemount Tank Radar AB
Address
Layoutvägen 1, 43533 Mölnlycke Sweden

View All Listings by this Company

Print This Approval


#2305913

Flow regulator with a plastic body. 4.0 - 8.5L/min. Claims of flow regulation performance made by manufacturer have note been tested and are not covered as part of this approval.

Non-metallic materials and components comply with BS6920 at 85°C

Section:
1530 Miscellaneous Fittings
WRAS Approval Number:
2305913
Size:
Ø20.37 x 19.33mm
Marking:
HL2024 FC (brand of HaGePe) on body
Installation Requirements:
R001
Expiry date:
31/05/2028
Model:
HL2024

Approval Holder:
HaGePe International B.V (HGP International)
Company Name
HaGePe International B.V (HGP International)
Address
Huizermaatweg 27-2 1273 NA Huizen
Country
Netherlands

View All Listings by this Company

Print This Approval


#2305911

Range of pressure, flow and temperature sensors. The VFI sensors have stainless steel bodies, all other models have plastic bodied sensors. The MFS and VFS models are supplied with a plastic (composite) or stainless-steel flow pipe. The VFI models are supplied with a stainless-steel flow pipe. The products can also be supplied with a range of fittings/end connections (see model and size). Maximum working pressures: ITS, LPS, RPS, MFS (composite flow pipe) and VFS (composite flow pipe) models: 24.0 bar. DPS: Models with vent hole: 16.0 bar. All other models: 24.0 bar. MFS (stainless steel flow pipe) and MFS (stainless steel flow pipe): 30.0 bar. VFI non-flanged models: 30.0 bar. VFI flanged models: 30.0 bar or as per flange PN rating 16.0 bar or 25.0 bar (whichever is lower). Maximum operating temperature 99°C.

Section:
1530 Miscellaneous Fittings
Size:
ITS/LPS/RPS: BRASS CW 617N: ¼" BSPP (M). S/S EN 14408: ½" BSPT (M). ½" BSPT (M) (short). ½" NPT (M). Plastic: ⅜" BSPP (M). DPS: BRASS CW 617N: ½" BSPT (M) w/vent hole. 15.5mm w/vent hole. S/S EN 1.4401: ½" BSPT (M) w/vent hole. Housing only S/S (EN 1.4408): 2x ⅛" NPT (F). End connections for housing only: AISI 316 6mm compression, 6mm and 8mm tube. MFS, VFS (COMPOSITE FLOWPIPE): FLOWPIPE ONLY: 1”, 1¼”, 1½” BSPP (M). END CONECTIONS: BRASS CW 617N: ½", ¾" BSPP (M). ¾", 1", 1¼" BSPT (M). ½", ¾", 1", 22mm, 28mm SWEAT. S/S EN 1.4401: ¾", 1", 1¼" NPT (M). 1", 1¼" BSPT (M). MFS, VFS (S/STEEL FLOWPIPE): FLOWPIPE ONLY (EN 1.4408): ¾", 1", 1¼" BSPP (M). ¾", 1", 1¼" NPSM (M). 1" FLANGE. END CONNECTIONS: BRASS CW 617N: ½", ¾", 1" BSPT (M). ¾", 1", 22mm & 28mm SWEAT. S/S EN 1.4401: ¾", 1" BSPT (M). ¾", 1" NPT (M). VFI: CAST IRON OR S/STEEL EN 1.4408 FLANGED: DN18/25/32 (1¼"). DN40/50 (2"). DN65/80/100. S/S EN 1.4401: 1”, 1¼" BSPT (M). 1, 1¼" NPT (M).
Marking:
VFI models: Grundfos and model type (VFI) on adhesive label on sensor. Grundfos on flow pipe. All other models: Grundfos on top of sensor housing. Model type (ITS/LPS/RPS/MFS/VFS) on adhesive label on sensor.
Installation Requirements:
R001
Expiry date:
31/05/2028
Model:
ITS LPS or RPS sensor alone (only for internal sale): Sensor/ AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF ITS, LPS or RPS with or without accessories (saleable): AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF/ GG/ HHH/ IIII Product: [A] Must be ITS, LPS or RPS Range and unit: [B] Of no importance for drinking water* Gen.: [C] Of no importance for drinking water* Output: [D] Of no importance for drinking water* Cable: [E] Of no importance for drinking water* Sealing: [F] The first character must be E, second and third character have no importance for drinking water* Materials: [G] Must be either -B, -S, -I or -- Connection: [H] Must be either 03A, 03B, 03N, 02P, 10K, 16P or --- Packaging: [I] Of no importance for drinking water* ------ DPS sensor alone (only for internal sale): Sensor/ AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF DPS with or without accessories (saleable): AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF/ GG/ HHH/ IIII Product: [A] Must be DPS Range and unit: [B] Of no importance for drinking water* Gen.: [C] All characters allowed except 4 and 5 Output: [D] Of no importance for drinking water* Cable: [E] Of no importance for drinking water* Sealing: [F] The first character must be E, the second must not be A. The third character has no importance for drinking water* character have no importance for drinking water* Materials: [G] Must be either -B, -S or -- Connection: [H] Must be either 06C, 06T, 08T, 10L, 24N, 63B, 64S or --- Packaging: [I] Of no importance for drinking water* ------ MFS or VFS sensor alone (only for internal sale): Sensor/ AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF MFS or VFS with or without composite flow pipe accessories (saleable): AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF/ GG/ HHH/ IIII Product: [A] Must be MFS or VFS Range and unit: [B] Of no importance for drinking water* Gen.: [C] Of no importance for drinking water* Output: [D] Of no importance for drinking water* Cable: [E] Of no importance for drinking water* Sealing: [F] The first character must be A or E, second and third character have no importance for drinking water* Materials: [G] Must be either CB, CS or -- Connection: [H] Must be either 03P, 03S, 04B, 04N, 04P, 04S, 05B, 05N, 05P, 05S, 07B, 07N, 07P, 09P, 10K, 15K, 18K, 22S, 28S or --- Packaging: [I] Of no importance for drinking water* ------ MFS or VFS sensor alone (only for internal sale): Sensor/ AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF MFS or VFS with or without stainless steel flow pipe accessories (saleable): AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF/ GG/ HHH/ IIII Product: [A] Must be MFS or VFS Range and unit: [B] Of no importance for drinking water* Gen.: [C] Of no importance for drinking water* Output: [D] Of no importance for drinking water* Cable: [E] Of no importance for drinking water* Sealing: [F] The first character must be A or E, second and third character have no importance for drinking water* Materials: [G] Must be either QB, QS, Q- or -- Connection: [H] Must be either 03B, 04B, 04M, 04N, 04P, 04S, 05B, 05M, 05N, 05P, 05S, 07M, 07P, 10K, 10L, 102, 22S, 28S, 51G or --- Packaging: [I] Of no importance for drinking water* ------ VFI sensor alone (only for internal sale): Sensor/ AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF VFI with or without accessories (saleable): AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF/ GG/ HHH/ IIII Product: [A] Must be VFI Range and unit: [B] Of no importance for drinking water* Gen.: [C] Of no importance for drinking water* Output: [D] Of no importance for drinking water* Cable: [E] Of no importance for drinking water* Sealing: [F] The first character must be E, second and third character have no importance for drinking water* Materials: [G] Must be either S-, SG or SS Connection: [H] Must be either 05B, 05N, 07B, 07N, 30F, 31F, 32F, 33F, 35F, 37F or 42F Packaging: [I] Of no importance for drinking water* ------ Where: Code for sealing [F]: 1st character: “A” means EPDM O-rings and EPDM sealing sleeve. “E” means EPDM O-rings. Code for material [G]: 1st character: “C” means composite flow pipe. “Q” means flow insert and (except service sets) also a stainless steel flow pipe. “S” means stainless steel adapter (for DPS) or flow pipe. “-“ means no adapter (for DPS) or flow pipe. 2nd character: "B" means brass (fitting). “G” means cast iron (flange). “I” means composite (fitting). "S" - means stainless steel (fitting or flange). “-“ means no further accessories included. Code for connection (H): 1st two characters: “02” means ¼”. “03” means ½”. “04” means ¾”. “05” means 1”. “06” means 6 mm. “07” means 1¼”. “08” means 8 mm. “09” means 1½”. (Internal note - this is on a flow pipe connection) “15” means 15 mm. “16” means ⅜”. “18” means 18 mm. “22” means 22 mm. “24” means ⅛”. “28” means 28 mm. “30” means DIN PN25/40 DN18/25/32, ANSI B16.5 Class 300 - 1¼". “31” means DIN PN16/25/40 DN40, ANSI B16.5 Class 300 - 2". “32” means DIN PN16/25/40 DN50, ANSI B16.5 Class 300 - 2". “33” means ISO/DIN PN25/40 DN65. “35” means ISO/DIN PN25/40 DN80. “37” means ISO/DIN PN16 DN100. “42” means ISO/DIN PN25/40 DN100. “51” means 1" / ¾". “63” means ½" and ventilation opening. “64” means 15.5 mm and ventilation opening. “--” means no accessories included and thus implicitly the dimension of the sensor connection, which for DPS, ITS, LPS, MFS, RPS and VFS is 10 mm (of no importance for drinking water). 3rd character: “A” means BSPT (short). “B” means BSPT. “C” means Compression. “F” means flange. “K” means standard clip included (of no importance for drinking water). “L” means special clip included (of no importance for drinking water). “M” means NPSM. “N” means NPT. “P” means BSPP. “R” means union not (union nut include but no fittings included). “S” means sweat. “T” means hose connector. “2” means both standard clip and special clip included (of no importance for drinking water). “-“means no accessories included and thus implicitly the connection type of the sensor, which for DPS, ITS, LPS, MFS, RPS and VFS is a clip (of no importance for drinking water). Further details on the nomenclature: * All characters are allowed NOTE - For customer-specific numbers, GG/HHH/IIII in the saleable code is replaced by the customer name. However, the customer-specific products are still covered if they meet the requirements specified in the standard sales code.

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7, DK-8850 Bjerringbro
Country
Denmark
Phone
+45 24610542

View All Listings by this Company

Print This Approval


#2306305

Range of temperature measurement devices with bronze bodies and EPDM o-rings. Maximum operating pressure 10.0 bar.

Non-metallic materials and components comply with BS6920 at 85°C

Section:
1530 Miscellaneous Fittings
Size:
see model;
Marking:
Kemper logo, size and flow arrow on body
Installation Requirements:
R001
Expiry date:
30/06/2028
Model:
6280G0XX00. XX stands for 15, 20, 25, 32, 40 or 50 related to the dimension of the sensor (mm).

Approval Holder:
Gebr. Kemper GmbH + Co. KG
Company Name
Gebr. Kemper GmbH + Co. KG
Address
Harkortstr. 5 57462 Olpe Germany
Phone
+49(0) 27618910
General Email
info@kemper-olpe.de

View All Listings by this Company
Manufacturer:
Gebr. Kemper GmbH + Co. KG
Company Name
Gebr. Kemper GmbH + Co. KG
Address
Harkortstr. 5 57462 Olpe Germany
Phone
+49(0) 27618910
General Email
info@kemper-olpe.de

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 28 of 32

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.