Section Code 0684 : Tap with a non-touch methods of flow control and a single inlet. Products listed in this section utilise flow control methods that do not require touch to activate.
Back To Directory SectionsRange of single hole, single outlet (fixed) electronically controlled tap assemblies in (chrome plated brass bodies). Flow is controlled with a solenoid valve activated via an infra-red sensor. The temperature is controlled via a single lever operating member on the body. The inlets incorporate stainless steel strainers and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlets incorporate a plastic aerator. Maximum working pressure 8.0 Bar
Non-metallic materials and components comply with BS6920 at 65°C
Range of single hole, single outlet, fixed, electronically controlled combination tap assemblies, (chrome plated brass bodies). Flow is controlled via an infra-red activated solenoid valve and the spout outlets incorporate plastic aerators. A stainless steel braided PEX lined flexible hose connects the components. Maximum working pressure 8.0 Bar
Non-metallic materials and components comply with BS6920 at 45°C
Single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass). Flow is controlled by a solenoid valve activated by via an infra-red sensor. The spout outlets incorporate a plastic aerator and flow regulator. The tap incorporates a soap dispenser with separate dispensing nozzle. Maximum working pressure 8.0 Bar. Maximum operating temperature 55°C.
Range of single hole, single outlet (fixed) electronically controlled tap assemblies (stainless steel or brass bodies – various finishes). Flow is controlled via solenoid valve (housed in a control box) actuated via an infra-red sensor, the inlets to the control box incorporate stainless steel strainers. The spout outlets incorporates plastic aerators. The products incorporate a stainless steel PEX lined flexible hose assembly, connecting the tap to the solenoid valve. Maximum working pressure 10.0 Bar
Non-metallic materials and components comply with BS6920 at 65°C
Range of wall mounted single hole, single outlet, fixed, electronically controlled tap assemblies (chrome plated brass bodies). Flow is controlled via an infra-red activated solenoid valve and model AF 1602 incorporates a plastic aerator in the spout outlet. Maximum working pressure 8.0 Bar Maximum operating temperature 45.0°C
Page 24 of 27
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.