Section Code 0470 : Single hole tap with a single outlet and a swivel spout. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
Back To Directory SectionsRange of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork and single lever operating member.The spout outlet incorporates a plastic aerator Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range single hole, single outlet swivel combination tap assemblies (brushed stainless steel) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Single hole, single outlet (swivel) combination tap assembly (chrome plated brass body). Incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator or flow straightener with a stainless steel and EPDM strainer. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The cold water inlet incorporate an approved check valve cartridge, verified by test (as suitable for backflow protection against Fluid Category 2) The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) incorporating quarter turn ceramic disk headworks with single lever operating members. The cold water inlets is supplied with a chrome plated brass adapter incorporating an approved check valve cartridge which has been verified by test (as suitable for backflow protection against Fluid Category 2) The spout outlets incorporate plastic aerators. Maximum working pressure 5 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly with brass body (chrome plated), incorporating ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a plastic aerator. The cold water inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (with various finishes). Incorporating a ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (swivel) combination tap assemblies (chrome plated brass). Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlets incorporate plastic flow straighteners. Maximum working pressure 10 bar. Maximum operating temperature 65°C
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (chromium or matt black finish), incorporating a ceramic cartridge headwork with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, metal, single outlet (swivel) combination tap assemblies (chromium plated or brushed brass) incorporating a ceramic cartridge or ceramic discs headwork with either single lever or cross top. The spout outlets incorporate a plastic aerator. The cold inlet incorporates an optional check valve cartridge (excluding model HS605) which has been verified by test as suitable for backflow protection against Fluid Category 2. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Page 24 of 35
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.