Section Code 2000 : Shower valve with manual temperature control.
Back To Directory SectionsWall mounted manually operated, concealed blending valve (brass body) incorporating a ceramic cartridge headwork controlling both flow and temperature with single lever operating member. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Concealed, wall mounted, manual shower blending valve incorporating a brass body, ceramic cartridge headwork and a self-cancelling diverter to a second shower outlet. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted manually operated, concealed blending valve (brass body) with a ceramic cartridge headwork controlling both flow and temperature with a XXXX operating member. Maximum working pressure 5.0 bar. Maximum operating temperature 90.0 °C
Wall mounted, concealed, manual blending valve with DZR brass body and chrome plated trim set, incorporating a quarter turn ceramic disc headwork controlling the flow and a ceramic cartridge controlling the temperature independently, bothwith dome type operating members. The inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Manually operated, wall mounted, concealed blending valve (cast brass body) incorporating a ceramic cartridge headwork with a single lever operating member controlling both flow and temperature. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of deck mounted, concealed, manually operated blending valves with brass bodies or stainless-steel bodies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Range of wall mounted thermostatic blending valves with brass bodies (various finishes). Incorporating quarter turn ceramic disc headworks and single lever operating member. The temperature is controlled independently via a thermostatic cartridge, single lever operating member and a manual override button. Inlets incorporate a strainer and single check valve cartridges however the complete assembly has not been tested to verify it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of manually operated, wall mounted, concealed blending valves with brass bodies (various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of manually operated, wall mounted, concealed blending valves with brass bodies (various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member and self-cancelling diverter. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of wall mounted, concealed, blending valve, incorporating brass bodies (chrome plated), quarter turn ceramic disc headworks with single lever operating members and a manual diverter diverting the flow to two outlets. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Page 3 of 8
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.