Unvented Heating Apparatus

Section Code 1890 :

Back To Directory Sections

#2103330

Stainless steel indirect thermal store. The primary circuit is factory fitted with a temperature and pressure relief valve (3 bar and 92°C). Hot water storage for space heating via air to water heat pump? Maximum working pressure: Primary circuit 3.0 bar Maximum operating temperature 85°C.

Section:
1890 Unvented Heating Apparatus
Size:
1 ¼” BSP(F) x 1 ¼” BSP(F)
Marking:
Polar Energi, model no, date of manufacture, capacity,& pressure on adhesive label on cover.
Installation Requirements:
R001 R140
Expiry date:
31/03/2026
Model:
VP380L

Approval Holder:
Polar Energi
Company Name
Polar Energi
Address
Polar Energi AS Bygdaveien 172 9450 Hamnvik
Country
Norway
Phone
+4777029222
General Email
post@polarenergi.com

View All Listings by this Company

Print This Approval


#2106034

Range of “POWERflow” Indirect and direct unvented storage cylinders consisting of factory fitted single or twin coil circuit with either a primary or solar coil. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 4.5 bar at 90˚C and an expansion relief valve set at 3.5 bar. The product is supplied with a pressure reducing valve set at 2.1 bar, expansion vessel, tundish and an approved check assembly (suitable for backflow protection against Fluid Category 2). Primary circuit max working pressure: 3.5 bar Secondary circuit max working pressure: 3.0 bar Solar Coil max working pressure: 3.5 bar Primary and Secondary circuit maximum operating temperature 75.0°C Solar Coil max operating temperature 80.0°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2106034
Size:
Primary Circuit: 22mm compression. Secondary circuit: 22mm compression. Solar circuit: 22mm compression. Drain connection: 15mm compression.
Marking:
McDonald Water Storage, POWERflow and other product info on labels on body.
Installation Requirements:
R001 R140 R360
Expiry date:
30/06/2026
Proviso:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°C and 45°C.
Model:
POWERflow Range of unvented hot water storage cylinders: 75, 120, 150, 165, 180, 210, 250, 300 Litres Indirect & Direct. Solar Coil option on 120L and above. PD1 - 75 Litre Direct POWERflow, PI1 - 75 Litre Indirect POWERflow Size = 950 x 450mm Connections = 6 (Direct) / 9 (Indirect) PD2 - 120 Litre Direct POWERflow, PI2 - 120 Litre Indirect POWERflow Size = 950 x 550mm Connections = 6 (Direct) / 9 (Indirect) PD3 - 150 Litre Direct POWERflow, PI3 - 150 Litre Indirect POWERflow Size = 1150 x 550mm Connections = 7 (Direct) / 9 (Indirect) PD5 - 165 Litre Direct POWERflow, PI5 - 165 Litre Indirect POWERflow Size = 1250 x 550mm Connections = 7 (Direct) / 9 (Indirect) PD6 - 180 Litre Direct POWERflow, PI6 - 180 Litre Indirect POWERflow Size = 1350 x 550mm Connections = 8 (Direct) / 10 (Indirect) PD4 - 210 Litre Direct POWERflow, PI4 - 210 Litre Indirect POWERflow Size = 1550 x 550mm Connections = 8 (Direct) / 10 (Indirect) PD7 - 250 Litre Direct POWERflow, PI7 - 250 Litre Indirect POWERflow Size = 1550 x 600mm Connections = 8 (Direct) / 10 (Indirect) PD8 - 300 Litre Direct POWERflow, PI8 - 300 Litre Indirect POWERflow Size = 1850 x 600mm Connections = 8 (Direct) / 10 (Indirect)
Product Images

Approval Holder:
MCDONALD WATER STORAGE
Company Name
MCDONALD WATER STORAGE
Address
QUEENSWAY INDUSTRIAL ESTATE GLENROTHES FIFE
Postcode
KY7 5QF

View All Listings by this Company
Manufacturer:
MCDONALD WATER STORAGE
Company Name
MCDONALD WATER STORAGE
Address
QUEENSWAY INDUSTRIAL ESTATE GLENROTHES FIFE
Postcode
KY7 5QF

View All Listings by this Company

Print This Approval


#2107032

Mitsubishi Electric ‘EHPT20Q – VM2EA’ stainless steel unvented primary thermal store cylinder unit. An inline booster heater is also fitted into the primary circuit. The cylinder is fitted with two pressure relief valves set at 3.0 bar. Heat is transferred from the stored primary water to the secondary water circuit via a plate heat exchanger which provides instantaneous hot water. The primary thermal storage cylinder is to be filled by the use of the supplied temporary filling loop assembly, which consistd of a stainless steel braided EPDM lined flexible hose, a lever operated brass spherical valve and a DZR brass double check valve assembly (suitable for backflow protection against Fluid Category 3) that incorporates a lever operated spherical valve. A primary expansion vessel is supplied to accommodate the expansion of the primary water when heated. An automatic air vent is fitted to the top of the thermal store. The product is supplied with a tundish. Maximum working pressure: Primary circuit 2.5 bar, Secondary circuit 10.0 bar. Maximum operating temperature: Primary circuit 72°C, Secondary circuit 70°C.

Section:
1890 Unvented Heating Apparatus
Size:
Primary and Secondary circuit: 22mm connection. Outdoor heating unit: ½” BSP (M)
Marking:
Mitsubishi, model and technical information including capacity and pressure on adhesive label on top of unit.
Installation Requirements:
R001
Expiry date:
31/07/2026
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
EHPT20Q-VM2EA
Product Images

Approval Holder:
Mitsubishi Electric Air Conditioning Systems Europe Ltd
Company Name
Mitsubishi Electric Air Conditioning Systems Europe Ltd
Address
Nettlehill Road, Houston Industrial Estate, Livingston
Postcode
EH54 5EQ
Country
United Kingdom
Phone
01405 44 55 00

View All Listings by this Company

Print This Approval


#2103035

McDonald Steel Flow ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2103035
Size:
22mm compression (Inlet Manifold)
Marking:
McDonald Water Storage & Steel Flow on front, technical information on adhesive label on body.
Installation Requirements:
R001 R140 R360
Expiry date:
31/03/2026
Proviso:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°c and 45°c.
Model:
CS90D - MCDONALD STEELFLOW 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS120D - MCDONALD STEELFLOW 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS150D - MCDONALD STEELFLOW 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS170D - MCDONALD STEELFLOW 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS200D - MCDONALD STEELFLOW 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS250D - MCDONALD STEELFLOW 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS300D - MCDONALD STEELFLOW 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. CS90I - MCDONALD STEELFLOW 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS120I - MCDONALD STEELFLOW 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS150I - MCDONALD STEELFLOW 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. CS170I - MCDONALD STEELFLOW 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS200I - MCDONALD STEELFLOW 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS250I - MCDONALD STEELFLOW 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. CS300I - MCDONALD STEELFLOW 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS170DS - MCDONALD STEELFLOW 170 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER CS200DS - MCDONALD STEELFLOW 200 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER CS250DS - MCDONALD STEELFLOW 250 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER CS300DS - MCDONALD STEELFLOW 300 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER CS170IS - MCDONALD STEELFLOW 170 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER CS200IS - MCDONALD STEELFLOW 200 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER. CS325IS - MCDONALD STEELFLOW 250 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER CS300IS - 300 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER. CS60DSL - MCDONALD STEELFLOW SLIM 60 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS90DSL - MCDONALD STEELFLOW SLIM 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS120DSL - MCDONALD STEELFLOW SLIM 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS150DSL - MCDONALD STEELFLOW SLIM 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS170DSL - MCDONALD STEELFLOW SLIM 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS200DSL - MCDONALD STEELFLOW SLIM 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS60ISL - MCDONALD STEELFLOW SLIM 60 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS90ISL - MCDONALD STEELFLOW SLIM 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS120ISL - MCDONALD STEELFLOW SLIM 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS150ISL - MCDONALD STEELFLOW SLIM 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS170ISL - MCDONALD STEELFLOW SLIM 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS200ISL - MCDONALD STEELFLOW SLIM 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER
Product Images

Approval Holder:
MCDONALD WATER STORAGE
Company Name
MCDONALD WATER STORAGE
Address
QUEENSWAY INDUSTRIAL ESTATE GLENROTHES FIFE
Postcode
KY7 5QF

View All Listings by this Company

Print This Approval


#2103340

Stainless steel indirect thermal store. The primary circuit is factory fitted with a temperature and pressure relief valve (3 bar and 92°C). Hot water storage for space heating via air to water heat pump Maximum working pressure: Primary circuit 3.0 bar Maximum operating temperature 85°C.

Section:
1890 Unvented Heating Apparatus
Size:
1 ¼” BSP(F) x 1 ¼” BSP(F)
Marking:
Polar Energi, model no, date of manufacture, capacity,& pressure on adhesive label on cover.
Installation Requirements:
R001 R140
Expiry date:
31/03/2026
Model:
PAW-VP380L INDIRECT THERMAL STORE

Approval Holder:
Panasonic UK, a branch of Panasonic Marketing Europe GmbH
Company Name
Panasonic UK, a branch of Panasonic Marketing Europe GmbH
Address
Maxis 2 Western Road Bracknell Berkshire
Postcode
RG12 1RT

View All Listings by this Company
Manufacturer:
Polar Energi
Company Name
Polar Energi
Address
Polar Energi AS Bygdaveien 172 9450 Hamnvik
Country
Norway
Phone
+4777029222

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 3 of 7

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.