Heat Exchangers

Section Code 1350 :

Back To Directory Sections

#2012088

Range of waste water heat recovery systems incorporating a twin wall copper coil (7773414 models) or stainless steel (7771332 models). Maximum working pressure 10.0 bar. Cold water use only.

Section:
1350 Heat Exchangers
Size:
½” BSP (M) (7773414) or ¾” BSP (F) (7771332)
Marking:
BAXI, Model, and technical info on adhesive label located on plastic casing.
Installation Requirements:
R001
Expiry date:
31/12/2025
Model:
VERTICAL SHRU 7771332 & HORIZONTAL SHRU 7773414 HEAT EXCHANGERS

Approval Holder:
Baxi Heating UK Ltd.
Company Name
Baxi Heating UK Ltd.
Address
Club Street Bamber Bridge Preston Lancaster
Postcode
PR5 6FN

View All Listings by this Company

Print This Approval


#2012366

Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.

Section:
1350 Heat Exchangers
Size:
¾” BSP (M)
Marking:
RBM, address, serial number, technical & pressure information on label inside case.
Installation Requirements:
R001
Expiry date:
31/12/2025
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
37370000 ELECTRONICALLY CONTROLLED HEAT INTERFACE UNITS
Product Images

Approval Holder:
RBM S.p.a.
Company Name
RBM S.p.a.
Address
Componenti Per Impianti Idrotermici Via S. Giuseppe, 1 25075 Nave (Brescia)
Country
Italy

View All Listings by this Company

Print This Approval


#2105309

Copper heat transformer. Maximum working pressure 11.0 bar. Maximum operating temperature 95°C.

Section:
1350 Heat Exchangers
Size:
76mm copper tube
Marking:
Company name and address, model, operating parameters, size & date of manufacture (MM/YYYY) on body.
Installation Requirements:
R001
Expiry date:
31/05/2026
Model:
Heat Transformer 60
Product Images

Approval Holder:
Copper Industries Ltd
Company Name
Copper Industries Ltd
Address
Toome Business Park 21 Hillhead Road Toome Co Antrim
Postcode
BT41 3SF
Country
United Kingdom
Phone
02879 659736
General Email
mail@copperindustries.co.uk

View All Listings by this Company
Manufacturer:
Copper Industries Ltd
Company Name
Copper Industries Ltd
Address
Toome Business Park 21 Hillhead Road Toome Co Antrim
Postcode
BT41 3SF
Country
United Kingdom
Phone
02879 659736
General Email
mail@copperindustries.co.uk

View All Listings by this Company

Print This Approval


#2105044

Range of domestic hot water units incorporating instantaneous or semi-instantaneous plate heat exchanger assemblies. The product incorporates a motorised control valve, managed primary and secondary pumps (see model), and a drain valve on both circuits. Maximum working pressures: 10.0 bar primary, 9.5 bar secondary. Maximum operating temperatures: 110°C primary, 85°C secondary.

Section:
1350 Heat Exchangers
Size:
1 ¼” BSP (F) on both primary and secondary circuits.
Marking:
Cetetherm SAS, AQUAFIRST, Max working pressure/temperature for primary and secondary circuits, serial number, article number and year of manufacture (YYYY) on adhesive label on heat exchanger frame.
Installation Requirements:
R001 R140 R360
Expiry date:
31/05/2026
Model:
AQUAFIRST 2000/4000/6100/8000 series: Flxxnnyy FI = Aquafirst range xx = 20: 2000 M3 Plates serie (differentiation on primary side). 40: 4000 M3 Plates serie (differentiation on primary side). 61: 6100 M6 Plates serie (differentiation on primary side and secondary pump). 80: 8000 M6 Plates serie (differentiation on primary side and secondary pump). nn = 07 up to 55 for the number of gasketed plates. yy = IS: Instantaneous (no pump on DHW) with single primary pump ID: Instantaneous (no pump on DHW) with twin head primary pump SS: Semi-instantaneous with one primary pump and one DHW pump DS: Semi-instantaneous with twin head primary pump and one DHW pump DD: Semi-instantaneous with twin head primary pump and two DHW pump Article Number: FI2007IS. FI2007ID. FI2007SS. FI2007DS. FI2007DD. FI2017IS. FI2017ID. FI2017SS. FI2017DS. FI2017DD. FI4027IS. FI4027ID. FI4027SS. FI4027IS. FI4027DD. FI4045IS. FI4045ID. FI4045SS. FI4045DS. FI4045DD. FI6113IS. FI6113ID. FI6113SS. FI6113DS. FI6113DD. FI6123IS. FI6123ID. FI6123SS. FI6123DS. FI6123DD. FI8031IS. FI8031ID. FI8031SS. FI8031DS. FI8031DD. FI8055IS FI8055ID FI8055SS FI8055DS FI8055DD.
Product Images

Approval Holder:
CETETHERM SAS
Company Name
CETETHERM SAS
Address

View All Listings by this Company
Manufacturer:
CETETHERM SAS
Company Name
CETETHERM SAS
Address

View All Listings by this Company

Print This Approval


#2105021

Range of wastewater heat recovery systems incorporating stainless steel corrugated pipe. Maximum working pressure 16.0 bar. Cold water use only.

Section:
1350 Heat Exchangers
WRAS Approval Number:
2105021
Size:
¾” BSP (F) inlet x outlet.
Marking:
Zypho logo, model name, serial number, WRAS and other product info on adhesive label located on body.
Installation Requirements:
R001
Expiry date:
31/05/2026
Model:
ZYPHO PiPe 55 DW. ZYPHO PiPe 60 DW. ZYPHO PiPe 65 DW.

Approval Holder:
Zypho, SA
Company Name
Zypho, SA
Country
Portugal
Phone
+351 210 991 351
General Email
b2b@zypho.pt

View All Listings by this Company
Manufacturer:
Zypho, SA
Company Name
Zypho, SA
Country
Portugal
Phone
+351 210 991 351
General Email
b2b@zypho.pt

View All Listings by this Company

Print This Approval


#2105050

Range of wastewater heat recovery systems incorporating stainless steel corrugated pipe. Maximum working pressure 16.0 bar. Cold water use only.

Section:
1350 Heat Exchangers
WRAS Approval Number:
2105050
Size:
¾” BSP (F) inlet x outlet.
Marking:
MIRA SHOWERS, model name, serial number, WRAS and other product info on adhesive label located on body.
Installation Requirements:
R001
Expiry date:
31/05/2026
Model:
MIRA HEATCAPTURE

Approval Holder:
Kohler Mira Ltd.
Company Name
Kohler Mira Ltd.
Address
Cromwell Road, Cheltenham, Gloucestershire
Postcode
GL52 5EP
Country
United Kingdom
Phone
+44 (0) 844 571 5000

View All Listings by this Company

Print This Approval


#2109017

Range of outdoor air to water heat exchanger units incorporating a pump, drain valve and isolation valve. Maximum working pressure 5.0 bar. Maximum operating temperature 90°C

Section:
1350 Heat Exchangers
Size:
¾” BSP (F)
Marking:
Mitsubishi Heavy Industries and technical information on data plate on body.
Installation Requirements:
R001 R430 R510
Expiry date:
30/09/2026
Model:
ESA30E-25, ESA30EH-25 Model added June 2023 ESA30EH2-25
Product Images

Approval Holder:
Mitsubishi Heavy Industries Ltd
Company Name
Mitsubishi Heavy Industries Ltd
Address
3-1 Asahi Nishibiwajima-Cho Kiyosu
Country
Aichi

View All Listings by this Company
Manufacturer:
Mitsubishi Heavy Industries Ltd
Company Name
Mitsubishi Heavy Industries Ltd
Address
3-1 Asahi Nishibiwajima-Cho Kiyosu
Country
Aichi

View All Listings by this Company

Print This Approval


#2110022

Copper brazed micro plate heat exchanger with copper and stainless-steel (316/1.4401) plates. Maximum working pressure 25.0 Bar. Maximum operating temperature 100°C

Section:
1350 Heat Exchangers
Size:
¾” BSP (M)
Marking:
Danfoss company logo, model name, maximum temperature and pressure, date of manufacture (YYYY-MM-DD) and other technical infomation on adhesive label on front of heat exchanger.
Installation Requirements:
R001
Expiry date:
31/10/2026
Model:
XB06
Product Images

Approval Holder:
Danfoss A/S
Company Name
Danfoss A/S
Address
Nordborgvej 81 6430 Nordborg
Country
Denmark
Phone
+74 88 22 22
General Email
danfoss@danfoss.com

View All Listings by this Company
Manufacturer:
Danfoss Trata d.o.o.
Company Name
Danfoss Trata d.o.o.
Address
Joezeta Jame 16, SI-1210 Ljubljana Sentvid Slovenia
General Email

View All Listings by this Company

Print This Approval


#2201339

Range of stainless-steel plate heat exchangers with EPDM gaskets. The primary circuit, (excluding the E2 prefix models), incorporates a drain valve and a pump (excluding STP prefix models including an ‘N’ as the 14th figure). Operating parameters: Maximum working pressure of the secondary circuit: 6.0 bar or 10.0 bar (see model). Maximum working pressure of the primary circuit: E4 models: 6.0 bar. C3, E3, E2, i2: 10.0 bar. Models added February 2023 – Econoplate STP3, STC3, STP2, STC2 & STP4: 10.0 bar. Maximum operating temperature: Primary 140°C & Secondary 85°C.

Section:
1350 Heat Exchangers
Size:
Secondary: 1½” BSP (F) or 2” BSP (F), as well as 1” BSP (F) recirculation connection where fitted. Primary: DN40 or DN50 flanged inlet, 1½” BSP (M) or 2” BSP (M) outlet.
Marking:
Stokvis logo, Stokvis, Econoplate & model, pressure, flow rate, WRAS and other technical information on data plate on body.
Installation Requirements:
R001 R511
Expiry date:
31/01/2027
Model:
Econoplate models: Following models xx goes from 5-59 to denote number of plates. E4Axx, E4Aixx, E4Bxx, E4Bixx, E3A1xx, E3Ai1xx, C3Ai1xx, E3A3xx, E3Ai3xx, C3Ai3xx, i2Axx, i2Bxx, E2A(##)xx, E2B(##)xx, E4AxxD, E4AixxD, E4BxxD, E4BixxD, E3A1xxD, E3Ai1xxD, C3Ai1xxD, E3A3xxD, E3Ai3xxD, C3Ai3xxD, i2AxxD, i2BxxD. Following models xx goes from 11-74 to denote number of plates: E3Cxx, E3Cixx, C3Cixx, i2Cxx, E2C(##)xx, E3CxxD, E3CixxD, C3CixxD, i2CxxD. FIRST LETTER: E = MODELS PAINTED YELLOW. C = MODELS ARE IDENTICAL TO E MODELS BUT PAINTED WHITE. i = Fitted with a speed controlled primary pump (2 port models only). FIRST NUMBER: PRIMARY CONTROL VALVE TYPE/NO. OF PORTS - 2, 3 or 4. NEXT LETTER RELATES TO FRAME SIZE OR PRIMARY CONTROL SET (PUMP & OR CONTROL VALVE) SIZE: Frame size - A, B or C. When fitted with a speed controlled primary pump add an i (3 and 4 port models only). When fitted with twin head primary pump add a D to model designation after the number xx. xx = number of (heat exchanger) plates All model names are followed by +0R where: +0R = no secondary pump. ## added to differentiate primary fluids and can be replaced with the following: SW = steam to water. LTHWS = low temperature heating to domestic hot water. MTHWS = medium temperature heating to domestic hot water. Units with a secondary pressure of 10.0 bar use stainless connections and are denoted by ’10 bar’ at end of model number. Units with a secondary pressure of 6.0 bar use bronze connections which are standard fitment so no addition or alteration to model number. All models can be fitted with either 1.5” or 2” secondary circuit connections, this does not affect the product model number. Models added February 2023 - Econoplate STP3, STC3, STP2, STC2 & STP4: ST (first 2 figures) – Signifies a Stokvis product on all models. All Econoplate models are orange in colour. P or C (3rd figure) – Signifies small or large chassis (P = 1.5” primary connections, C = 2” primary connections). 2, 3, or 4 (4th figure) – Signifies configuration of chassis to suit control valve, 2, 3 or 4 port. A, B, or C (5th figure) – Signifies secondary connection sizes (A = 1.5”, B = 2.0”, C = 2.0” stainless). 5 – 59 (P chassis), 11 – 74 (C chassis) (6th & 7th figure) – Signifies number of identical plates on unit. H, L, or M (8th Figure) – Signifies heat exchanger plate design (H = High theta, L = Low theta, M (mixed) = Combination of H & L). T1 or T2 (9th & 10th figure) – Signifies type of control panel (T1 = Standard control panel, T2 = Touchscreen premium panel). 2, 3, or 4 (11th figure) – Signifies primary control valve/s configuration (2 = 2 port, 3 = 3 port, 4 = 4 port). S, D, or N (12th figure) – Signifies primary pump configuration (S = Single head, D = Dual head, N = No primary pump fitted). 1 or 4 (13th figure) – Signifies number of temp sensors fitted to unit (1 = 1, 4 = 4). N (14th Figure) – Signifies no secondary pump fitted. Example: STP3A17HT13S4N
Product Images

Approval Holder:
Stokvis Energy Systems
Company Name
Stokvis Energy Systems
Address
96R Walton Road East Molesey Surrey
Country
KT8 0DL

View All Listings by this Company
Manufacturer:
Stokvis Energy Systems
Company Name
Stokvis Energy Systems
Address
96R Walton Road East Molesey Surrey
Country
KT8 0DL

View All Listings by this Company

Print This Approval


#2201323

Domestic hot water heat recovery unit incorporating a stainless-steel plate heat exchanger and cylinder. Maximum working pressure 3.0 bar. Maximum operating temperature 60°C.

Section:
1350 Heat Exchangers
Size:
15mm copper tail
Marking:
Baxi, Assure FGHR1, date of manufacturer (YYWW) on body.
Installation Requirements:
R001 R140
Expiry date:
31/01/2027
Model:
Baxi Assure FGHR1
Product Images

Approval Holder:
Baxi Heating UK Limited
Company Name
Baxi Heating UK Limited
Address
Brooks House, Coventry Road, Warwick
Postcode
CV34 3LL

View All Listings by this Company
Manufacturer:
Baxi Heating UK Limited
Company Name
Baxi Heating UK Limited
Address
Brooks House, Coventry Road, Warwick
Postcode
CV34 3LL

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 3 of 5

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.