Section Code 5030 : Factory applied pipe & fittings coatings.
Back To Directory Sections'MEKCOAT Liquid Membrane Coating'. Factory applied, two-component, blue coloured polyurethane coating. Mix in a 1:1 volume ratio. Cure for 24 hours@23-24°C. For use with water up to 85°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
'5017 Blue'. Factory applied, blue coloured epoxy powder coating. Apply as per manufacturer's instructions issued January 2020, 'V7.2'. Cure for 15 minutes@200°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'JH'. Factory applied, blue coloured epoxy powder coating. Heat substrate to 220°C for 30 minutes, spray apply coating and then cure at 190°C for 20 minutes. For use with water up to 23°C. This material is only approved for the application and curing conditions that appear on the approval. If the cure and/or application conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘EUROKOTE® 46-20’. Factory applied, red-brown coloured, two-part epoxy resin coating. Mix and apply as per manufacturer's technical data sheet 'Doc. 087' dated 01/07/2011. Cure for 7 days@20°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
`Electroline ES 1212-Black`. Factory applied, black coloured, 2 part epoxy coating. Mix parts A&B in a 3:1 volume ratio. Cure for 7 days@30°C. For use with water up to 85°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
Page 18 of 69
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.