TEST SITE

Combination Tap Assemblies

Section Code 0445 : Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.

Back To Directory Sections

#2303065

Range of single hole single outlet fixed combination tap assemblies, (chrome plated brass), incorporating a quarter turn ceramic disc headwork with a single lever operating member and non-rising spindle headwork with a variety of operating members (See models) controlling the flow to the additional swivel spout. The product incorporates a handheld pre-rinse spray with a self-closing trigger, either on a flexible hose within an overhead spring or as a fixed length flexible hose on a swivel arm (see model). The inlets incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The outlet of the swivel spouts incorporates plastic aerators. Maximum working pressure 8.6 bar.

Non-metallic materials and components comply with BS6920 at 65°C

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2303065
Size:
½” BSP (M).
Marking:
Top line on body. ENCORE (brand of CHG Europe B.V.) on trigger mechanism.
Installation Requirements:
R001 R006
Expiry date:
31/03/2028
Model:
Flexible hose within an overhead spring: TW 20-116111-S3, TW 20-117111-S3, TW 20-116111-S3-DA1, TW 20-116111-S3-DA2, TW 20-116111-S3-DA3, TW 20-116111-S3-DA4, TW 20-117111-S3-DA1, TW 20-117111-S3-DA2, TW 20-117111-S3-DA3, TW 20-117111-S3-DA4. Fixed length flexible hose on a swivel arm: TW 20-510411-S3, TW 20-511411-S3, TW 20-510411-S3-DA1, TW 20-510411-S3-DA2, TW 20-510411-S3-DA3, TW 20-510411-S3-DA4, TW 20-511411-S3-DA1, TW 20-511411-S3-DA2, TW 20-511411-S3-DA3, TW 20-511411-S3-DA4. The final number = type of operating member. 1 = Single lever, 2 = Cross top, 3 = Triangle handle, 4 = Designer lever.

Approval Holder:
CHG Europe B.V.
Company Name
CHG Europe B.V.
Postcode
THE NETHERLANDS

View All Listings by this Company

Print This Approval


#2303057

Range of deck mounted, single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating either quarter turn ceramic disc or quarter turn compression washer headworks with various operating members (see model). The inlets of the quarter turn ceramic disc headworks incorporate an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The product incorporates a handheld pre-rinse spray with a self-closing trigger, either on a flexible hose within an overhead spring or as a fixed length flexible hose on a swivel arm (see model). Models are available with an additional swivel spout outlet, which incorporates a plastic aerator (see model). The swivel spouts have their own flow control in addition to the main headwork, this is also a quarter turn compression washer headwork with various operating members (see model). The product is supplied with metal backnuts. Maximum working pressure 6.0 bar.

Non-metallic materials and components comply with BS6920 at 65°C

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2303057
Size:
Stainless steel braided PEX lined flexible hose assemblies incorporating ½” captive nut end connections.
Marking:
ENCORE (brand of CHG Europe B.V.) on body and hand spray.
Installation Requirements:
R001 R006 R009 R010
Expiry date:
31/03/2028
Model:
KW 51 X1 X2 X3 X4 X5 X6 S3 (D A X7) K = Encore series. W = WRAS series. 51 = Single hole deck mount double pantry. X1 = 1 - Spring pre-rinse. 5 - Swivel arm pre-rinse - 12” arm length. X2 (Main body headwork) = 0 - Compression. 1 - Ceramic. X3 (Swivel arm support/Spring type) = 0 - W/O Swivel arm P/R support. 1 - W/ Swivel arm P/R support. 6 - Spring chrome plated. 7 - Spring stainless steel. X4 (riser) = 1 - 18” riser (only on spring type pre-rinse). 4 - 32” riser (only on swivel type pre-rinse). X5 (wall bracket) = 1 - Yes X6 (Main body operating member) = 1 - Standard lever. 2 - Cross. 3 - Triangle handle. 4 - Designer handle. 5 - 4” Wrist blade. 6 - 6” Wrist blade. S3 - Standard spray valve Optional: D - Add on faucet W/ 12” spout A - 0.5 GPM PCA Spray vandal resistant X7 (Add-on spout operating member) = 1 - Standard lever. 2 - Cross. 3 - Triangle handle. 4 - Designer handle.
Product Images

Approval Holder:
CHG Europe B.V.
Company Name
CHG Europe B.V.
Postcode
THE NETHERLANDS

View All Listings by this Company

Print This Approval


#2303058

Range of deck mounted, single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disc or a quarter turn compression washer headwork with various operating members (see model). The inlet of the quarter turn ceramic disc headwork incorporates an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The product incorporates a handheld pre-rinse spray with a self-closing trigger, either on a flexible hose within an overhead spring or as a fixed length flexible hose on a swivel arm (see model). Models are available with an additional swivel spout outlet, which incorporates a plastic aerator (see model). The swivel spouts have their own flow control in addition to the main headwork, this is also a quarter turn compression washer headwork with various operating members (see model). The product is supplied with metal backnuts. Maximum working pressure 6.0 bar.

Non-metallic materials and components comply with BS6920 at 65°C

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2303058
Size:
½” BSP (M).
Marking:
ENCORE (brand of CHG Europe B.V.) on body and hand spray.
Installation Requirements:
R001 R006
Expiry date:
31/03/2028
Model:
KW 63 X1 X2 X3 X4 X5 X6 S3 (D A X7) K = Encore series. W = WRAS series. 63 = Single hole deck mount single pantry. X1 = 1 - Spring pre-rinse. 5 - Swivel arm pre-rinse - 12” arm length. X2 (Main body headwork) = 0 - Compression. 1 - Ceramic. X3 (Swivel arm support/Spring type) = 0 - W/O Swivel arm P/R support. 1 - W/ Swivel arm P/R support. 6 - Spring chrome plated. 7 - Spring stainless steel. X4 (riser) = 1 - 18” riser (only on spring type pre-rinse). 4 - 32” riser (only on swivel type pre-rinse). X5 (wall bracket) = 1 - Yes X6 (Main body operating member) = 1 - Standard lever. 2 - Cross. 3 - Triangle handle. 4 - Designer handle. 5 - 4” Wrist blade. 6 - 6” Wrist blade. S3 - Standard spray valve Optional: D - Add on faucet W/ 12” spout A - 0.5 GPM PCA Spray vandal resistant X7 (Add-on spout operating member) = 1 - Standard lever. 2 - Cross. 3 - Triangle handle. 4 - Designer handle.
Product Images

Approval Holder:
CHG Europe B.V.
Company Name
CHG Europe B.V.
Postcode
THE NETHERLANDS

View All Listings by this Company

Print This Approval


#2212099

Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) incorporating ceramic cartridge headworks with single lever operating member. The outlet is a pull-out spray type and incorporates a plastic aerator. The inlet hoses incorporate stainless steel strainers. Models 5059340452869 have a maximum working pressure of 10.0 bar. All other models have a maximum working pressure of 5.0 bar.

Non-metallic materials and components comply with BS6920 at 60°C

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2212099
Size:
Stainless steel braided PEX lined flexible hose assemblies. Models 5059340504469: 3/8” captive nut. All other models: ½” captive nut.
Marking:
Kingfisher Good Home Logo & Date of Manufacture MM/YYYY on body
Installation Requirements:
R001 R009 R090
Expiry date:
31/12/2027
Model:
5059340504469, 5059340504421, 5059340452869, 5059340452876, 5059340452883, 5059340452890, 5059340452791 & 5059340452807

Approval Holder:
Kingfisher International Products Ltd.
Company Name
Kingfisher International Products Ltd.
Address
3 Sheldon Square, Paddington, London
Postcode
W2 6PX

View All Listings by this Company

Print This Approval


#2301345

Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (chrome plated) and pull-out spray. The products incorporate a ceramic cartridge headwork with single lever operating member. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2301345
Size:
Stainless steel braided PEX lined flexible hose assemblies incorporating ½” BSP captive nut end connections.
Marking:
Gessi on operating member
Installation Requirements:
R001 R009 R010 R090
Expiry date:
31/01/2028
Model:
60433, 60435, 60485 & 60465

Approval Holder:
Gessi S.p.A.
Company Name
Gessi S.p.A.
Address
Parco Gessi - Fraz. Vintebbio 13037 Serravalle Sesia
Country
Italy
Phone
+39 0163 454111
General Email
gessi@gessi.it

View All Listings by this Company
Manufacturer:
Gessi S.p.A.
Company Name
Gessi S.p.A.
Address
Parco Gessi - Fraz. Vintebbio 13037 Serravalle Sesia
Country
Italy
Phone
+39 0163 454111
General Email
gessi@gessi.it

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 14 of 16

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.