TEST SITE

Combination Tap Assemblies

Section Code 0445 : Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.

Back To Directory Sections

#2303033

Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet is a pull-down spray type incorporating a push button. The connection to the pull-down hose incorporates an approved single check valve cartridge, however, the whole product has not been fully tested to demonstrate that it provides backflow protection. Maximum working pressure 5.0 Bar.

Non-metallic materials and components comply with BS6920 at 65°C

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2303033
Size:
Stainless steel braided flexible hose assemblies with ½” BSP (F) conical nut end connections.
Marking:
PPI laser etched on base of body
Installation Requirements:
R001 R090
Expiry date:
31/03/2028
Model:
217019 217019 MBK1 217019 BGP

Approval Holder:
PPI Xiamen Industry Co Ltd
Company Name
PPI Xiamen Industry Co Ltd
Address
No 88 South Houxiang Road Xinyang Industrial Zone Haicang District Xiamen 361022
Country
China

View All Listings by this Company
Manufacturer:
PPI Xiamen Industry Co Ltd
Company Name
PPI Xiamen Industry Co Ltd
Address
No 88 South Houxiang Road Xinyang Industrial Zone Haicang District Xiamen 361022
Country
China

View All Listings by this Company

Print This Approval


#2303073

Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet is a pull-down spray type incorporating a push button. The connection to the pull-down hose incorporates an approved single check valve cartridge, however, the whole product has not been fully tested to demonstrate that it provides backflow protection. Maximum working pressure 5.0 Bar.

Non-metallic materials and components comply with BS6920 at 65°C

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2303073
Size:
Stainless steel braided flexible hose assemblies with ½” BSP (F) conical nut end connections.
Marking:
TP on base of body
Installation Requirements:
R001 R090
Expiry date:
31/03/2028
Model:
357181 PULL OUT MONOBLOC MIXER KITCHEN TAP CHROME & BLACK HOSE

Approval Holder:
Travis Perkins Plc
Company Name
Travis Perkins Plc
Address
Divisional Office Lakeside House Bedford
Postcode
NN4 7HD
Country
Northhampton
Phone
+44 (0) 1604 503457

View All Listings by this Company

Print This Approval


#2304028

Range of single hole or two-hole pre-rinse taps (chromium plated brass bodies) which have either a single outlet or two outlets. The flow is controlled by rising spindle headworks with single lever operating members and the spout outlet incorporates a plastic flow straightener. Model 89001MN-2 is a single hole tap with two outlets; a spout (swivel) outlet and pull-down pre-rinse assembly which incorporates a trigger mechanism. Models 98001-1, 98001-1-01, 98001MN-1, 98001MN-1-01 are two-hole taps with a single outlet; a pull-down pre-rinse assembly which incorporates a trigger mechanism. Models 98007MN-2, 98007MN-2-01, 98007-2 & 98007-2-01 are two-hole taps with two outlets; a spout (swivel) outlet and pull-down pre-rinse assembly which incorporates a trigger mechanism. Models 98007MN-1 & 98007MN-1-01 are two-hole taps with a single outlet; a pull-down pre-rinse assembly which incorporates a trigger mechanism. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.

Non-metallic materials and components comply with BS6920 at 65°C

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2304028
Size:
M8 or ½” BSP (F)
Marking:
Top Rinse and WRAS on body.
Installation Requirements:
R001 R010 R006
Expiry date:
30/04/2028
Model:
98001MN-2 MINI, 98001-1, 98007-2-01, 98001-1-01, 98001MN-1 MINI, 98001MN-1-01 MINI, 98007MN-2 MINI, 98007MN-2-01 MINI, 98007-2, 98007MN-1 MINI & 98007MN-1-01.

Approval Holder:
Zhejiang Sunmixer Sanitary Ware Co.,Ltd
Company Name
Zhejiang Sunmixer Sanitary Ware Co.,Ltd
Address
Science & Technology Industrial Zone, Chumen, Yuhuan, Zhejiang
Country
China
Phone
+86-576-87121119

View All Listings by this Company
Manufacturer:
Zhejiang Sunmixer Sanitary Ware Co.,Ltd
Company Name
Zhejiang Sunmixer Sanitary Ware Co.,Ltd
Address
Science & Technology Industrial Zone, Chumen, Yuhuan, Zhejiang
Country
China
Phone
+86-576-87121119

View All Listings by this Company

Print This Approval


#2005374

Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a pull out spray with push button trigger assembly and dome type operating member. The pull out spray also incorporates a single check valve assembly (however the complete unit has not been tested to demonstrate it provides adequate backflow protection). The outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2005374
Size:
Stainless steel braided PEX lined hose assembly incorporating 3/8” captive nut end connections
Marking:
Grohe on body.
Installation Requirements:
R001 R009 R090
Expiry date:
31/05/2025
Model:
30442000 30442DC0 30443000 30443DC0 30444000 30444AL0 30444DC0 30444DL0 31615GN0 30444GN0 31615BE0 31615EN0 31615GL0 31615DA0 31615A00

Approval Holder:
Grohe Deutschland Vertriebs GmbH
Company Name
Grohe Deutschland Vertriebs GmbH
Address
Zur Porta 9, 32457 Porta Westfalica
Country
Germany

View All Listings by this Company

Print This Approval


#2303064

Range of single hole single outlet fixed combination tap assemblies, (chrome plated brass), incorporating quarter turn ceramic disc headworks with a single lever operating member and non-rising spindle headwork with a variety of operating members (See models) controlling the flow to the additional swivel spout. The product incorporates a hand held pre-rinse spray with a self-closing trigger, either on a flexible hose within an overhead spring or as a fixed length flexible hose on a swivel arm (see model). The inlets incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The outlet of the swivel spouts incorporates plastic aerators. These products are supplied with metal back nuts. Maximum working pressure 8.6 bar.

Non-metallic materials and components comply with BS6920 at 65°C

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2303064
Size:
Stainless steel braided PEX lined flexible hose assemblies incorporating ½” captive nut end connections.
Marking:
Top line on body. ENCORE (brand of CHG Europe B.V.) on trigger mechanism.
Installation Requirements:
R001 R006 R009 R010
Expiry date:
31/03/2028
Model:
Flexible hose within an overhead spring: TW 51-116111-S3, TW 51-117111-S3, TW 51-116111-S3-DA1, TW 51-116111-S3-DA2, TW 51-116111-S3-DA3, TW 51-116111-S3-DA4, TW 51-117111-S3-DA1, TW 51-117111-S3-DA2, TW 51-117111-S3-DA3, TW 51-117111-S3-DA4. Fixed length flexible hose on a swivel arm: TW 51-510411-S3, TW 51-511411-S3, TW 51-510411-S3-DA1, TW 51-510411-S3-DA2, TW 51-510411-S3-DA3, TW 51-510411-S3-DA4. TW 51-511411-S3-DA1 TW 51-511411-S3-DA2 TW 51-511411-S3-DA3 TW 51-511411-S3-DA4 The final number = type of operating member. 1 = Single lever, 2 = Cross top, 3 = Triangle handle, 4 = Designer lever.

Approval Holder:
CHG Europe B.V.
Company Name
CHG Europe B.V.
Postcode
THE NETHERLANDS

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 13 of 16

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.