Float Operated Inlet Valve
Section Code 2075 : Can be used to achieve a recognised air gap arrangement, providing it meets the appropriate backflow requirements. Suitable for use in a WC suite, provided it forms an arrangement which meets the requirements of Type AUK1 air gap and an appropriate WC performance specification.
Back To Directory Sections
WRAS Approval Number: #2007326
Bottom entry BS1212-4 (2016) compact type float operated inlet valve for WC flushing cisterns with a plastic body and adjustable float, EPDM ‘O’-rings and a plastic flow regulator at the inlet.
Maximum working pressure 10.0 bar. Cold water use only.
- Section:
- 2075 Float Operated Inlet Valve
- Section Subtitle:
- Can be used to achieve a recognised air gap arrangement, providing it meets the appropriate backflow requirements. Suitable for use in a WC suite, provided it forms an arrangement which meets the requirements of Type AUK1 air gap and an appropriate WC performance specification.
- WRAS Approval Number:
- 2007326
- Size:
- ½” BSP (M)
- Marking:
- Oli, BS1212-4, manufacturing date and time (DD/MM/YY) on body
- Installation Requirements:
- R001 R550 R560
- Expiry date:
- 31/07/2025
- Model:
-
AG104 Plus bottom entry
Product Images
- Approval Holder:
- Oli-Sistemas Sanitarios, S.A
Company Name
Oli-Sistemas Sanitarios, S.A
View All Listings by this Company - Manufacturer:
- Oli-Sistemas Sanitarios, S.A
Company Name
Oli-Sistemas Sanitarios, S.A
View All Listings by this Company
WRAS Approval Number: #2006029
Bottom entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a plastic strainer.
Maximum working pressure 10.0 bar. Cold water use only.
- Section:
- 2075 Float Operated Inlet Valve
- Section Subtitle:
- Can be used to achieve a recognised air gap arrangement, providing it meets the appropriate backflow requirements. Suitable for use in a WC suite, provided it forms an arrangement which meets the requirements of Type AUK1 air gap and an appropriate WC performance specification.
- WRAS Approval Number:
- 2006029
- Size:
- ½” BSP (M)
- Marking:
- Shuochen logo, BS 1212-4 and datum level on cap
- Installation Requirements:
- R001 R550 R560
- Expiry date:
- 30/06/2025
- Model:
-
2103
- Approval Holder:
- Changge Shuochen Bathroom Co. Ltd.
Company Name
Changge Shuochen Bathroom Co. Ltd.
View All Listings by this Company - Manufacturer:
- Changge Shuochen Bathroom Co. Ltd.
Company Name
Changge Shuochen Bathroom Co. Ltd.
View All Listings by this Company
WRAS Approval Number: #2010055
Range of side entry BS1212-4 (2016) delayed action or non-delayed action type float operated valves for WC flushing cisterns. The inlet incorporates an optional flow restrictor.
Maximum working pressure 10.0 bar.
Cold water use only.
- Section:
- 2075 Float Operated Inlet Valve
- Section Subtitle:
- Can be used to achieve a recognised air gap arrangement, providing it meets the appropriate backflow requirements. Suitable for use in a WC suite, provided it forms an arrangement which meets the requirements of Type AUK1 air gap and an appropriate WC performance specification.
- WRAS Approval Number:
- 2010055
- Size:
- 1/2” BSP (M) & 3/8” BSP (M)
- Marking:
- Trademark WDI, ECO model number (B3230) and BS1212-4.
On side of body.
- Installation Requirements:
- R001 R550
- Expiry date:
- 31/10/2025
- Model:
-
B3230 Side entry inlet valve with G1/2” plastic threaded connection.
B3230 Side entry inlet valve with G1/2” brass threaded connection.
B3230 Side entry inlet valve with G3/8” plastic threaded connection.
Product Images
- Approval Holder:
- ECO (Xiamen) Technology INC.
Company Name
ECO (Xiamen) Technology INC.
View All Listings by this Company - Manufacturer:
- ECO (Xiamen) Technology INC.
Company Name
ECO (Xiamen) Technology INC.
View All Listings by this Company
WRAS Approval Number: #2011333
Side entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a strainer. Maximum working pressure 10.0 bar. Cold water use only.
- Section:
- 2075 Float Operated Inlet Valve
- Section Subtitle:
- Can be used to achieve a recognised air gap arrangement, providing it meets the appropriate backflow requirements. Suitable for use in a WC suite, provided it forms an arrangement which meets the requirements of Type AUK1 air gap and an appropriate WC performance specification.
- WRAS Approval Number:
- 2011333
- Size:
- 3/8” BSP (M).
- Marking:
- Grohe, date of manufacture (YYMM) & other information on body. BS1212-4 on valve cap.
- Installation Requirements:
- R001 R550 R573
- Expiry date:
- 30/11/2025
- Model:
-
492.854
Product Images
- Approval Holder:
- Grohe AG
Company Name
Grohe AG
Address
Industriepark Edelburg,
58675 Hemer
Country
Germany
Phone
02372 930
General Email
info@grohe.com
View All Listings by this Company - Manufacturer:
- Grohe AG
Company Name
Grohe AG
Address
Industriepark Edelburg,
58675 Hemer
Country
Germany
Phone
02372 930
General Email
info@grohe.com
View All Listings by this Company
WRAS Approval Number: #2011343
Side entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a plastic filter.
Maximum working pressure 10.0 bar. Cold water use only.
- Section:
- 2075 Float Operated Inlet Valve
- Section Subtitle:
- Can be used to achieve a recognised air gap arrangement, providing it meets the appropriate backflow requirements. Suitable for use in a WC suite, provided it forms an arrangement which meets the requirements of Type AUK1 air gap and an appropriate WC performance specification.
- WRAS Approval Number:
- 2011343
- Size:
- 3/8” BSP (M) brass
Models added January 2021
½” BSP (M) brass or plastic
- Marking:
- Siamp, BS1212-4, WRAS logo and EN14124-11 on float
- Installation Requirements:
- R001 R550 R573
- Expiry date:
- 30/11/2025
- Model:
-
Compact 95L Air Gap
Product Images
- Approval Holder:
- Siamp Vietnam
Company Name
Siamp Vietnam
Postcode
MONACO
View All Listings by this Company - Manufacturer:
- Siamp Vietnam
Company Name
Siamp Vietnam
Postcode
MONACO
View All Listings by this Company
Back To Directory Sections Page 2 of 10