Section Code 1530 :
Back To Directory SectionsRange of below ground hose union taps within a chamber incorporating a brass spherical valves, hose connector and MDPE couplings. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C
Range of stainless-steel bellows with screwed ends. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Top entry compression cylinder flange with DZR brass body and copper anti-aeration dip tube. Maximum working pressure 4.0 bar. Maximum operating temperature 60°C.
Range of flow sensors with plastic bodies and plastic turbines. Maximum operating temperature 65°C.
Range of pressure transmitters with stainless steel bodies and EPDM ‘O’-rings. Maximum working pressures: 520 XXX range 100.0 bar, 522 XXX range & 540 XXX range 60.0 bar. Maximum operating temperature 520 XXX & 522 XXX range 99°C & 540 XXX range 80°C.
Crane brass pressure test point. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Hattersley brass pressure test point. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
‘Cart’ range of plastic flow regulators within a plastic housing and either silicone, EPDM or NBR sealing gaskets and optional stainless steel filter. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Wall plate elbow (105° angle) with a brass body. Maximum operating temperature 100°C
Manifold with a brass body and 5 outlets. Maximum working pressure 15.0 bar. Maximum operating temperature 100°C.
Range of axial expansion joints with either threaded or flanged end connections. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
In-line plastic flow regulator housed within a brass body (chrome plated) or stainless steel body (HL2024 Cradle model only) incorporating a plastic strainer and EPDM ‘O’-rings. HL2024 Inline 1P BSP threaded models also have NBR/fibre gaskets. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Plastic bodied flow sensor. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
‘Nova-Flo’ inline flow control device with a plastic body and EPDM ‘O’-rings. The product is intended to restrict the flow of water to a bath or basin if water level reaches the overflow. Float located within the overflow pathway activate flaps on each inlet to restrict the flow prior to the taps being closed. Maximum Working pressure 10.0 bar. Maximum operating temperature 60°C.
Hansen range of nylon BSP threaded fittings. For use above and below ground. Maximum working pressure 6mm - 50mm: 16.0bar, 65mm: 12.0bar, 80mm - 100mm: 10.0bar. Cold water use only.
NIVUS range of flow sensors with stainless steel bodies. Sensors incorporate EPDM seals and a PTFE olive. Maximum working pressure 16.0 bar. Cold water use only.
Range of shower hoses and riser rail with chromium plated brass bodies, incorporating EPDM ‘O’-rings. Maximum operating temperature 85°C.
Shower hose and handset with sliding rail and inlet kit. The inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of plastic manifold systems designed to accept interchanagble sensors (not supplied). Maximum working pressure 6.0 bar. Cold water use only.
Immersion temperature sensors with DZR bodies and an EPDM ‘O’-ring (STDW14 model only). Maximum working pressure 15.0 bar. Maximum operating temperature 100°C.
Range of shock arrestors with carbon steel or stainless steel bodies (available in various external surface finishes) incorporating Bromobutyl (BIIR) membranes. Maximum working pressure 10.0 bar. Cold water use only.
Range of shock arrestors with stainless steel bodies incorporating Bromobutyl (BIIR) membranes. Maximum working pressure 10.0 bar. Cold water use only.
Air break to drain, incorporating brass bodies with a grey epoxy powder coating. Maximum operating temperature 60°C.
Impeller with plastic body for insertion into specifically dimensioned bores. Maximum operating temperature 70°C.
Wall mounted chrome plated brass elbow fitting. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Hygienic flush box providing a timed flush facility. The supply is via a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection, flow sensor, spherical ball valve and strainer. The products incorporate a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The units have multiple interface user functions for timed flush, wireless technology and data storage. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Maincor Manifold having a brushed chrome plated body with 2 ,3 or 4 ports each with an isolation valve with red or blue indicators for hot and cold feeds. Supplied with a blanking plug and nut. Maximum working pressure 6.0 bar. Maximum operating temperature 75°C.
Assembly of pipe and fittings for use Arjo Huntleigh assisted bathing units. The assemblies comprise of either brass compression fittings or plastic push fit fittings for use with Uponor WIrsbo PEX pipe. The inlet of the 22mm assembly incorporates a combined spherical valve and strainer with brass body and stainless-steel filter. The strainer incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Maximum operating temperature for assemblies incorporating brass compression fittings is 80°C. Maximum operating temperature for assemblies incorporating PEX push fit fittings is 50°C.
Range of flow sensors incorporating either brass, plastic or stainless steel bodies & EPDM ‘O’-rings. Maximum working pressure 10.0 bar for models VVXA, VVXC, VVXB. Maximum working pressure 16.0 bar for models VVXD & VVXE. Maximum operating temperature 90°C.
Range of in-line plastic flow regulators. The flow regulator is housed within a black plastic body incorporating a plastic strainer and an EPDM ‘O’-ring. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of flow through valves with brass bodies and EPDM ‘O’-rings, incorporating a spherical valve and a separate drain tap. The products are intended for connection prior to an expansion vessel. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of water monitoring systems comprising of a battery or mains operated latching solenoid valve (plastic body) and a flow sensor. The units are supplied with a hand-held controller. Maximum working pressure 10.0 bar. Cold water use only.
Range of click type pop-up wastes with brass bodies and EPDM rubber seals. Product is supplied with plastic back nuts.
Range of flow measurement devices (DZR brass) bodies incorporating two test ports. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of screwed gland cock valves with bronze bodies, EPDM seats and ‘O’-rings. The products incorporate a hose union outlet connection. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Range of DZR brass metering stations supplied with red and blue test points for upstream and downstream port identification. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Flow sensor with a plastic body. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Quick connector for connecting mixed water outlets to flexible hoses. Maximum operating temperature 60°C.
Range of pump docking manifolds with plastic bodies and NBR, EPDM and FKM ‘O’-rings. Maximum working pressure 8.0 bar. Cold water use only.
Automatic, electronic, water control system, intended to be used for leak detection. Maximum working pressure 10.0 bar. Cold water use only.
Stainless steel bodied sensor with EPDM ‘O’-ring. Maximum operating temperature 90°C.
Range of flow sensors with brass bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 90°C
Range of wall mounted shower arms and shower handsets with brass bodies (various finishes), the inlets to the shower handsets incorporating a flow restrictor. Maximum operating temperature 60°C.
Thermostatic element with copper shell, polyethylene tube and PTFE gasket. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of threaded fittings with either plain brass, nickel plated brass or chrome plated brass bodies. Maximum operating pressure 16.0 bar. Maximum operating temperature 99°C.
Wallgate CWC Series 250 WC pan with direct acting flush valve and DFKIT03 air break (DC device). WC flushing mechanism has a solenoid valve controlling the flow, the valves are operated via an infrared sensor or a piezo control button, this mechanism is fitted with a DC pipe interrupter, the DFKIT03 is fitted with a flow regulator. Maximum working pressure 2.0 bar. Cold water use only.
Shower kit, intended for use with ovens, incorporating a triple layered hose on a reel and a push-button operated shower handset. The inlet of the shower handset incorporates a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 4.0 bar. Cold water use only.
Range of circulation valves and flow sensor valves with EPDM seals and O-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 90ºC.
Range of concealed bathroom boxes with extractable shower hoses. The inlet attached to the concealed box incorporates an approved single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The outlet of the shower hose also includes a stainless steel strainer. Maximum operating temperature 60°C.
Range of pressure transmitters with stainless steel bodies. Maximum working pressures: DST-P140 model 25.0 bar, all other models 50.0 bar. Maximum operating temperature 90°C.
Page 1 of 4
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.