TEST SITE

Combination Tap Assemblies

Section Code 0445 : Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.

Back To Directory Sections

#2007806

Single hole single outlet (swivel) pull out spray combination tap assembly (chromium plated brass) with ¼ turn ceramic disc headwork and single lever operating members. The spout outlet incorporates a plastic flow aerator and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2007806
Size:
Stainless steel braided EPDM lined hose assembly incorporating ½” captive nut end connections.
Marking:
PPI on rear of body
Installation Requirements:
R001 R090
Expiry date:
31/07/2025
Model:
907015

Approval Holder:
PPI Xiamen Industry Co Ltd
Company Name
PPI Xiamen Industry Co Ltd
Address
No 88 South Houxiang Road Xinyang Industrial Zone Haicang District Xiamen 361022
Country
China

View All Listings by this Company
Manufacturer:
PPI Xiamen Industry Co Ltd
Company Name
PPI Xiamen Industry Co Ltd
Address
No 88 South Houxiang Road Xinyang Industrial Zone Haicang District Xiamen 361022
Country
China

View All Listings by this Company

Print This Approval


#2007808

Single hole single outlet (swivel) pull out spray combination tap assembly (chromium plated brass) with ¼ turn ceramic disc headwork and single lever operating members. The spout outlet incorporates a plastic flow aerator and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2007808
Size:
Stainless steel braided EPDM lined hose assembly incorporating ½” captive nut end connections.
Marking:
TP ON BASE
Installation Requirements:
R001 R090
Expiry date:
31/07/2025
Model:
546885

Approval Holder:
Travis Perkins Plc
Company Name
Travis Perkins Plc
Address
Divisional Office Lakeside House Bedford
Postcode
NN4 7HD
Country
Northhampton
Phone
+44 (0) 1604 503457

View All Listings by this Company

Print This Approval


#2007314

Single hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating ceramic cartridge headworks and single lever operating member. The flexible spout outlet incorporates a plastic aerator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2007314
Size:
Stainless steel braided EPDM lined hose assembly incorporating ½” captive nut end connections
Marking:
DTC25 on rear of body. DEVA on front of the body.
Installation Requirements:
R001 R090
Expiry date:
31/07/2025
Model:
BDG104 – Bridgewater Flexi sink mixer.
Product Images

Approval Holder:
Methven UK Limited
Company Name
Methven UK Limited
Address
3-3A Stone Cross Court, Yew Tree Way, Golborne, Warrington
Postcode
WA3 3JE
Country
United Kingdom
Phone
0800 195 1602

View All Listings by this Company

Print This Approval


#2005321

Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a pull out spray with push button trigger assembly and dome type operating member. The pull out spray also incorporates a single check valve assembly (however the complete unit has not been tested to demonstrate it provides adequate backflow protection). The outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2005321
Size:
Stainless steel braided PEX lined hose assembly incorporating 3/8” captive nut end connections
Marking:
Grohe logo, design and engineering, Grohe Germany, date of manufacture (YYMM) Grohe ID made in label on body.
Installation Requirements:
R001 R009 R090
Expiry date:
31/05/2025
Model:
Grohe ‘Minta Smart Control’ sink mixers with L-spout and pull-out spray: 31.613. 31.613.A00 (hard graphite). 31.613.AS0 (satin black). 31.613.DA0 (Warm Sunset). 31.613.DC0 (supersteel). Grohe ‘Messence Smart Control’ sink mixers with L-spout and pull-out spray: 31.615. 31.615.A00 (hard graphite). 31.615.AL0 (brushed hard graphite). 31.615.AS0 (satin black). 31.615.BE0 (polished nickel). 31.615.DA0 (Warm Sunset). 31.615.DC0 (supersteel). 31.615.DL0 (brushed warm sunset). Grohe ‘Zedra Smart Control’ sink mixers with L-spout and pull-out spray: 31.593.002. 31.593.DC2 (supersteel).

Approval Holder:
Grohe AG
Company Name
Grohe AG
Address
Industriepark Edelburg, 58675 Hemer
Country
Germany
Phone
02372 930
General Email
info@grohe.com

View All Listings by this Company
Manufacturer:
Grohe AG
Company Name
Grohe AG
Address
Industriepark Edelburg, 58675 Hemer
Country
Germany
Phone
02372 930
General Email
info@grohe.com

View All Listings by this Company

Print This Approval


#2007385

Single hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating ceramic cartridge headworks and single lever operating member. The flexible spout outlet incorporates a plastic aerator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2007385
Size:
Stainless steel braided EPDM lined hose assembly incorporating ½” captive nut end connections
Marking:
DTC25 (brand of Methven) & Methven on body.
Installation Requirements:
R001 R090
Expiry date:
31/07/2025
Model:
HASMCP COMBINATION TAP ASSEMBLIES

Approval Holder:
Methven UK Limited
Company Name
Methven UK Limited
Address
3-3A Stone Cross Court, Yew Tree Way, Golborne, Warrington
Postcode
WA3 3JE
Country
United Kingdom
Phone
0800 195 1602

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1 of 16

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.