Section Code 0009 : SCHEDULE 2 - Section 6.2 - Type AB - Air gap with weir overflow.
Back To Directory SectionsRainwater harvesting back up device used to top up rainwater harvesting tanks with mains water. The device is fed by a solenoid valve and discharges via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 10.0 bar. Cold water use only.
Type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5) and flexible hose. Flow is controlled via a solenoid valve. Maximum working pressure 4.0 bar. Maximum operating temperature 55°C
Rainwater top up cistern with flow controlled by solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Product also incorporates a stop valve, a flow restrictor and a float valve on the inlet. Maximum working pressure 10.0 bar. Cold water use only.
Standpipe assembly break tank with a Type ‘AB’ air gap (verified by test – suitable for backflow protection against fluid category 5) mounted to the top of the standpipe body. The tank is filled via a compact float valve and has two screened weir slots. Water is then supplied by gravity from the break tank to the hose outlet below. Flow is activated via a spherical valve located behind a lockable panel. In addition to the isolation valve, the product incorporates a single check valve assembly (suitable for backflow protection against Fluid Category 2) prior to the spherical valve and an in-line ‘Y’ pattern strainer after it. The spherical valve includes a drain plug to allow for draining. Insulation is provided up to the drain point. Maximum working pressure 10.0 bar. Cold water use only.
Type ‘AB’ air gap assembly (verified by test - suitable for backflow protection against Fluid Category 5) with flow controlled via a solenoid valve. Supplied with EPDM inlet hoses that incorporate a single check valve cartridge, however the check valve has not been fully tested to demonstrate it provides backflow protection. Max working pressure 6.0 bar. Maximum operating temperature 60ºC.
Page 1 of 2
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.