TEST SITE

Genn Tapps Ltd. Approvals


#240904101

Wall mounted, exposed, two-hole single outlet, fixed, combination tap assemblies (brass body – various finishes) incorporating two ‘detent’ (push to on push to off) headworks, one controlling the flow to the bath outlet and the other to the shower outlet. The temperature is controlled independently via a thermostatic cartridge with a single lever operating member incorporating a manual override button. Both inlets and the shower outlet incorporate an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The inlets also incorporate a stainless-steel strainer. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Non-metallic materials and components comply with BS6920 at 60°C

Section:
0540 Combination Tap Assemblies
Section Subtitle:
Two hole tap with a single outlet and shower outlet.
WRAS Approval Number:
240904101
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (M).
Marking:
Gen Tapp on top of body.
Metals:
Approval holder declares that all metals in water pathway are on the positive list
Lead:
Approval holder declares that all metals in water pathway are lead free
Installation Requirements:
R001 R010 R040
Expiry date:
30/09/2029
Model:
CD 222 XXX Recessed shower control Where xxx denotes the surface finish (which is a non-water contact part). It will always be 3 digits, which can be any combination of numbers and/or letters. As examples: 000 = chrome optic finish, 800 = PVD stainless steel optic finish.

Approval Holder:
Genn Tapps Ltd.
Company Name
Genn Tapps Ltd.
Address
123 Mainn Road
Postcode
W22 4BB
General Email
j-doe@gtapp.com

View All Listings by this Company
Manufacturer:
Genn Tapps Ltd.
Company Name
Genn Tapps Ltd.
Address
123 Mainn Road
Postcode
W22 4BB
General Email
j-doe@gtapp.com

View All Listings by this Company

Print This Approval


#250108301

Section:
0450 Combination Tap Assemblies
Description:
A Range of Single hole tap with a single outlet and a fixed spout. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
Deck Mounted Stainless steel braided EPDM lined flexible hose assemblies incorporating ½” captive nut end connections. Supplied with click type waste, Not Tested Tap Gap AUK3 when installed in line with the IRN's
Basis of Compliance:
Tested to a standard assessed as an appropriate British Standard by WRAS
Installation Requirements:
R001 R005 R010
Expiry date:
31/01/2030

Product IdentificationSurface finishInlet DimensionMax Wrk. PressureMax Op. Temp.MarkingMarking LocationAll metals in the water pathway are on the 4msi positive listHeadworkFixing TypeSpout Outlet Includes
TAPP 1234 Cchrome1/2" BSP5 bar60 °CGenn TappsOperating MemberYes1/2 Turn ceramic diskC-plateAeratorFlow Regulator Fitted,
TAPP 1234 BLKBlack1/2" BSP5 bar60 °CGenn TappsOperating MemberYes1/2 Turn ceramic diskC-plateAeratorFlow Regulator Fitted,
Product Images

Approval Holder:
WRAS
Company Name
WRAS
Address
General Email
jason.furnival@wras.co.uk

View All Listings by this Company
Manufacturer:
Genn Tapps Ltd.
Company Name
Genn Tapps Ltd.
Address
123 Mainn Road
Postcode
W22 4BB
General Email
j-doe@gtapp.com

View All Listings by this Company

Print This Approval


#250108303

Section:
0450 Combination Tap Assemblies
Description:
A Range of Single hole tap with a single outlet and a fixed spout. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
Deck Mounted Stainless steel braided EPDM lined flexible hose assemblies incorporating ½” captive nut end connections. Supplied with click type waste, Not Tested Tap Gap AUK3 when installed in line with the IRN's
Basis of Compliance:
Tested to a standard assessed as an appropriate British Standard by WRAS
Installation Requirements:
R001 R005 R010
Expiry date:
31/01/2030

Product IdentificationSurface finishInlet DimensionMax Wrk. PressureMax Op. Temp.MarkingMarking LocationAll metals in the water pathway are on the 4msi positive listHeadworkFixing TypeSpout Outlet Includes
TAPP 1234 Cchrome1/2" BSP5 bar60 °CGenn TappsOperating MemberYes1/2 Turn ceramic diskC-plateAeratorFlow Regulator Fitted,
TAPP 1234 BLKBlack1/2" BSP5 bar60 °CGenn TappsOperating MemberYes1/2 Turn ceramic diskC-plateAeratorFlow Regulator Fitted,

Approval Holder:
Genn Tapps Ltd.
Company Name
Genn Tapps Ltd.
Address
123 Mainn Road
Postcode
W22 4BB
General Email
j-doe@gtapp.com

View All Listings by this Company
Manufacturer:
Genn Tapps Ltd.
Company Name
Genn Tapps Ltd.
Address
123 Mainn Road
Postcode
W22 4BB
General Email
j-doe@gtapp.com

View All Listings by this Company

Print This Approval


#250202301

Section:
0684 Combination Tap Assemblies
Description:
A Range of Tap with a non-touch methods of flow control and a single inlet. Products listed in this section utilise flow control methods that do not require touch to activate.
Deck Mounted Infra red controlled Stainless steel braided PEX lined flexible hose assembly with a 3/8” BSP (F) end connections. The Xeris models (012930699 & 012940699) incorporate a check valve cartridge in the inlet hose, however the complete assembly has not been tested to demonstrate it provides backflow protection.
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Installation Requirements:
001 006 009
Expiry date:
28/02/2030

Product IdentificationSurface finishInlet DimensionMax Wrk. PressureMax Op. Temp.MarkingMarking LocationAll metals in the water pathway are on the 4msi positive listHeadworkFixing TypeSpout Outlet Includes
012000699ChromiumStainless steel braided PEX lined flexible hose assembly with a 3/8” BSP captive nut end connections10 bar60 °CSchellBodyYesSolenoidC-plateAerator
012120699ChromiumStainless steel braided PEX lined flexible hose assembly with a 3/8” BSP captive nut end connections10 bar60 °CSchellBodyYesSolenoidC-plateAerator
012300699ChromiumStainless steel braided PEX lined flexible hose assembly with a 3/8” BSP captive nut end connections10 bar60 °CSchellBodyYesSolenoidC-plateAerator
012310699ChromiumStainless steel braided PEX lined flexible hose assembly with a 3/8” BSP captive nut end connections10 bar60 °CSchellBodyYesSolenoidC-plateAerator
021680699ChromiumStainless steel braided PEX lined flexible hose assembly with a 3/8” BSP captive nut end connections10 bar60 °CSchellBodyYesSolenoidC-plateAerator
021690699ChromiumStainless steel braided PEX lined flexible hose assembly with a 3/8” BSP captive nut end connections10 bar60 °CSchellBodyYesSolenoidC-plateAerator
021720699ChromiumStainless steel braided PEX lined flexible hose assembly with a 3/8” BSP captive nut end connections10 bar60 °CSchellBodyYesSolenoidC-plateAerator
021720613ChromiumStainless steel braided PEX lined flexible hose assembly with a 3/8” BSP captive nut end connections10 bar60 °CSchellBodyYesSolenoidC-plateAerator
021730699ChromiumStainless steel braided PEX lined flexible hose assembly with a 3/8” BSP captive nut end connections10 bar60 °CSchellBodyYesSolenoidC-plateAerator
021730613ChromiumStainless steel braided PEX lined flexible hose assembly with a 3/8” BSP captive nut end connections10 bar60 °CSchellBodyYesSolenoidC-plateAerator
012930699ChromiumStainless steel braided PEX lined flexible hose assembly with a 3/8” BSP captive nut end connections10 bar60 °CSchellBodyYesSolenoidC-plateAerator
012940699ChromiumStainless steel braided PEX lined flexible hose assembly with a 3/8” BSP captive nut end connections10 bar60 °CSchellBodyYesSolenoidC-plateAerator

Notes & Further Information

The difference between the article 02172 series and 02173 series is the power supply: 02172 series is with battery pack and 02173 series is with power adapter. The difference between the article 0699 and 0613 is only the package for different distribution targets. Two infrared modules are used. The modules used in article 01200, 01212, 01230, 01231, 01293 and 01294 are identical The modules used in article 02168, 02169, 02172 series and 02173 series are identical


Approval Holder:
Genn Tapps Ltd.
Company Name
Genn Tapps Ltd.
Address
123 Mainn Road
Postcode
W22 4BB
General Email
j-doe@gtapp.com

View All Listings by this Company
Manufacturer:
Genn Tapps Ltd.
Company Name
Genn Tapps Ltd.
Address
123 Mainn Road
Postcode
W22 4BB
General Email
j-doe@gtapp.com

View All Listings by this Company

Print This Approval


#250314301

Section:
0465 Combination Tap Assemblies
Description:
A Range of Single hole tap with a single outlet and a fixed spout, incorporating a self-cancelling diverter to a shower outlet. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
big tap deck mounted ~AUK 2
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Installation Requirements:
R001
Expiry date:
31/03/2030

Product IdentificationSurface finishInlet DimensionMax Wrk. PressureMax Op. Temp.MarkingMarking LocationAll metals in the water pathway are on the 4msi positive listHeadworkFixing TypeSpout Outlet Includes
dfdsfdssdffdssdfds bardfds °CsdfdssssssdNo

Notes & Further Information

Test this works now

Product Images

Approval Holder:
Genn Tapps Ltd.
Company Name
Genn Tapps Ltd.
Address
123 Mainn Road
Postcode
W22 4BB
General Email
j-doe@gtapp.com

View All Listings by this Company
Manufacturer:
Genn Tapps Ltd.
Company Name
Genn Tapps Ltd.
Address
123 Mainn Road
Postcode
W22 4BB
General Email
j-doe@gtapp.com

View All Listings by this Company

Print This Approval


Show Per Page
5102050Show All

Back To Directory Sections

Page of 1

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.