Xiamen Lota International Co. Ltd. Approvals


#2006028

Deck mounted, single hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60ºC.

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole tap with a single outlet and a fixed spout. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2006028
Size:
Stainless steel braided, PEX lined flexible hose assembly with a ½” BSP (F) captive nut
Marking:
Lota on rear of body
Installation Requirements:
R001 R006 R009 R010
Expiry date:
30/06/2025
Model:
62853-7001

Approval Holder:
Xiamen Lota International Co. Ltd.
Company Name
Xiamen Lota International Co. Ltd.
Address
No 61 Xingnan Road Jimei District Xiamen 361022

View All Listings by this Company
Manufacturer:
Xiamen Lota International Co. Ltd.
Company Name
Xiamen Lota International Co. Ltd.
Address
No 61 Xingnan Road Jimei District Xiamen 361022

View All Listings by this Company

Print This Approval


#2101021

Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) incorporating a ceramic cartridge headwork controlling the hot and cold flow. The 63264 model also incorporates a push to open, push to close, ‘detent’ headwork intended to control a filtered water supply. The spout outlets incorporate a plastic aerator. The cold water inlet hose is supplied with a chrome plated brass adaptor (½” BSP (F) x ½” BSP (M)) incorporating a check valve cartridge verified by test (suitable for backflow protection against Fluid Category 2). The 63264 model is also supplied with brass tee piece (½” BSP (F) x ½” BSP (M) x spigot (for quick connector)) for connection prior to the brass adaptor containing the check valve cartridge. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole tap with a single outlet and a swivel spout. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2101021
Size:
Stainless steel braided PEX lined flexible hose assemblies with ½" captive nut end connections. ½" BSP (F) on cold inlet (to adaptor or tee piece).
Marking:
LOTA on operating member.
Installation Requirements:
R001 R006 R009 R010
Expiry date:
31/01/2026
Model:
63263-0001 (Chrome). 63263-0004 (Brushed Nickel). 63263-006801 (Matt Black). 63263-004408 (Brushed Brass). 63264-0001 (Chrome). 63264-0004 (Brushed Nickel). 63264-016801 (Matt Black). 63264-004408 (Brushed Brass). 63267-0001 (Chrome). 63267-0004 (Brushed Nickel). 63267-016801 (Matt Black). 63267-004408 (Brushed Brass).

Approval Holder:
Xiamen Lota International Co. Ltd.
Company Name
Xiamen Lota International Co. Ltd.
Address
No 61 Xingnan Road Jimei District Xiamen 361022

View All Listings by this Company

Print This Approval


#2107060

Single-hole single outlet (swivel) combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member and a pull-out spray. The pull-out spray hose is stainless steel braided and has a. The pull-out spray outlet incorporates a button which changes and/or stops the flow of water, a plastic aerator and check valve cartridge however the complete product has not been fully tested to demonstrate it provides backflow protection.

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2107060
Size:
Stainless steel braided PEX lined flexible hose assemblies incorporating ½” captive nut end connections.
Marking:
LOTA on base of body
Installation Requirements:
R001 R009 R090
Expiry date:
31/07/2026
Model:
62871-0001
Product Images

Approval Holder:
Xiamen Lota International Co. Ltd.
Company Name
Xiamen Lota International Co. Ltd.
Address
No 61 Xingnan Road Jimei District Xiamen 361022

View All Listings by this Company
Manufacturer:
Xiamen Lota International Co. Ltd.
Company Name
Xiamen Lota International Co. Ltd.
Address
No 61 Xingnan Road Jimei District Xiamen 361022

View All Listings by this Company

Print This Approval


Show Per Page
5102050Show All

Back To Directory Sections

Page of 1

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.