#2309333

Single hole, single outlet, (swivel) combination tap assembly, incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a pull-down hose and a plastic aerator. The inlet hoses incorporate approved check valve cartridges, however, the complete assembly has not been fully tested to it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2309333
Size:
Stainless steel braided EPDM lined, flexible hose with ½” BSP (M) connection.
Marking:
SMR on underside of handle
Installation Requirements:
R001 R006 R010
Expiry date:
30/09/2028
Model:
GENIO

Approval Holder:
Norcros Group (Holdings) Limited T/A Abode
Company Name
Norcros Group (Holdings) Limited T/A Abode
Address
Unit L Zenith Park Whailey Road
Postcode
S75 1HT
Phone
01226 283434
General Email
pillingworth@abodedesigns.co.uk

View All Listings by this Company
Manufacturer:
SAN MARCO RUBINETTERIA S.r.l.
Company Name
SAN MARCO RUBINETTERIA S.r.l.
Address
Via Carducci 10 13867 Pray (BI)
General Email

View All Listings by this Company

Print This Approval


#2309334

Single hole, single outlet (swivel) combination tap assembly (chrome plated brass body). Incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5 bar. Maximum operating temperature 60°C

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole tap with a single outlet and a swivel spout. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2309334
Size:
Stainless steel braided EPDM lined flexible hose assembly incorporating 15mm compression end connections.
Marking:
SMR on plinth
Installation Requirements:
R001 R006 R010
Expiry date:
30/09/2028
Model:
Upton.

Approval Holder:
Norcros Group (Holdings) Limited T/A Abode
Company Name
Norcros Group (Holdings) Limited T/A Abode
Address
Unit L Zenith Park Whailey Road
Postcode
S75 1HT
Phone
01226 283434
General Email
pillingworth@abodedesigns.co.uk

View All Listings by this Company
Manufacturer:
SAN MARCO RUBINETTERIA S.r.l.
Company Name
SAN MARCO RUBINETTERIA S.r.l.
Address
Via Carducci 10 13867 Pray (BI)
General Email

View All Listings by this Company

Print This Approval


#2309335

Single hole, single outlet (swivel) combination tap assembly (chromIum plated brass bodies) incorporating a ceramic cartridge headwork with single lever type operating member. The spout outlet incorporates an aerator. The cold inlet incorporates an approved check valve cartridge however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5 bar. Maximum operating temperature 60°C

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole tap with a single outlet and a swivel spout. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2309335
Size:
Stainless steel braided or nylon braided EPDM lined flexible hose assemblies incorporating ½” BSP captive nut end connections. On hot and ½” BSP male connection on the cold inlet.
Marking:
SMR etched on rear of body
Installation Requirements:
R001 R006 R010
Expiry date:
30/09/2028
Model:
LOG L SWIVEL LOG J SWIVEL

Approval Holder:
SAN MARCO RUBINETTERIA S.r.l.
Company Name
SAN MARCO RUBINETTERIA S.r.l.
Address
Via Carducci 10 13867 Pray (BI)

View All Listings by this Company
Manufacturer:
SAN MARCO RUBINETTERIA S.r.l.
Company Name
SAN MARCO RUBINETTERIA S.r.l.
Address
Via Carducci 10 13867 Pray (BI)

View All Listings by this Company

Print This Approval


#2309331

Single-hole, single outlet, (swivel), combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The outlet is a pull-out spray type that incorporates a plastic aerator. The inlet of the cold supply hose and the pull-out spray handset both incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Tap incorporating a pull-out/pull down spray where the airgap cannot be maintained after motive force is removed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2309331
Size:
Cold inlet: Stainless-steel braided EPDM lined flexible hose assemblies incorporating ½” BSP (M) end connection. Hot inlet: Stainless-steel braided EPDM lined flexible hose assemblies incorporating ½” BSP captive nut end connection.
Marking:
SMR on body.
Installation Requirements:
R001 R090
Expiry date:
30/09/2028
Model:
Log L Pull Out

Approval Holder:
SAN MARCO RUBINETTERIA S.r.l.
Company Name
SAN MARCO RUBINETTERIA S.r.l.
Address
Via Carducci 10 13867 Pray (BI)

View All Listings by this Company
Manufacturer:
SAN MARCO RUBINETTERIA S.r.l.
Company Name
SAN MARCO RUBINETTERIA S.r.l.
Address
Via Carducci 10 13867 Pray (BI)

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 4 of 4

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.