Dutypoint Ltd. Approvals


#2006082

Range of cold water supply booster sets, incorporating a stainless steel manifold system and between 1 and 4 pumps depending on model. The booster sets also incorporate spherical valves, non-return valves, pressure switches/sensors and expansion vessels. Maximum working pressure 10.0 bar or 16.0 bar, dictated by the pump model(s) fitted. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2006082
Size:
Manifold connections (suction and discharge): 1”, 1 ¼”, 1 ½”, 2”, 2 ½” or 3” BSP (M).
Marking:
DUTYPOINT, model, serial number and technical information on adhesive label on control panel.
Installation Requirements:
R001 R415
Expiry date:
30/06/2025
Model:
VGw-xHMEyy-LSz: SERIES COLD WATER BOOSTER SETS w = Number of pumps: 1/2/3 x = Nominal flow rate in m3/h: 1/3/5/10/15/22 yy = Number of impellers: 02-25 z = Power supply: • M = single phase 1 x 230V • T = three phase 3 x 400V Example code: VG2-5HME06-LSM

Approval Holder:
Dutypoint Ltd.
Company Name
Dutypoint Ltd.
Address
Olympus Park, Quedgeley Gloucestershire
Postcode
GL2 4DH
General Email
sales@dutypoint.com

View All Listings by this Company

Print This Approval


#2011326

Range of submersible pumps with stainless steel bodies, impellers and shaft. The XPW range incorporates a strainer cowl on the suction end of the pump. The XPWA range features a stainless head which provides a threaded connection instead of the strainer. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2011326
Size:
XPW: 1¼” BSP (F). XPWA: 1¼” BSP (F) x 1½” BSP (F).
Marking:
Dutypoint, model and other technical information on adhesive label on body.
Installation Requirements:
R001 R415
Expiry date:
30/11/2025
Model:
(XPW)(i)(ii)-(iii) and (XPWA)(i)(ii)-(iii) ranges. Where: XPW or XPWA = range name. (i) = Nominal flow in m³/h x 10 (3, 5 or 9). (ii) = Number of stages x 10 (040-100). (iii) = Voltage/motor speed (M = single phase 230V, T = Three phase 400V, T230 = Three phase 230V. All of which can also be prefixed with 6 for 60Hz motor speed. Std. is 50Hz). Example codes: XPW3040-M & XPWA9090-T230.
Product Images

Approval Holder:
Dutypoint Ltd.
Company Name
Dutypoint Ltd.
Address
Olympus Park, Quedgeley Gloucestershire
Postcode
GL2 4DH
General Email
sales@dutypoint.com

View All Listings by this Company

Print This Approval


#2011357

Dutypoint ‘VS’ range of cold water supply booster sets, incorporating 2 to 8 pumps with a modular stainless steel manifold system. The booster sets also incorporate spherical valves, non-return valves, pressure switches/sensors and expansion vessels.. Maximum working pressure 10.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2011357
Size:
DN80 flanged inlet/outlet.
Marking:
Dutypoint logo, model no, serial no, company address and other technical information on control box.
Expiry date:
30/11/2025
Model:
VS(i)-(ii)-(iii)(iv)(v) VS = Product range prefix (i) = Number of pumps: 2, 3, 4, 6 or 8 (6 and 8 pump variants will be 2 x 3 pump units or 2 x 4 pump units coupled together). (ii) = Pump Model (4 digits): 3040, 3060, 3080, 3100, 5040, 5060, 5080, 5100, 9040, 9060, 9070 & 9090. (iii) Motor kW size (multiplied by 10): 005, 007, 011, 015, 022, 030. (iv) Power supply type: M (single phase) or T (three phase). Model code example: VS4-9090-030T.
Product Images

Approval Holder:
Dutypoint Ltd.
Company Name
Dutypoint Ltd.
Address
Olympus Park, Quedgeley Gloucestershire
Postcode
GL2 4DH
General Email
sales@dutypoint.com

View All Listings by this Company
Manufacturer:
Dutypoint Ltd.
Company Name
Dutypoint Ltd.
Address
Olympus Park, Quedgeley Gloucestershire
Postcode
GL2 4DH
General Email
sales@dutypoint.com

View All Listings by this Company

Print This Approval


#2110123

Range of vertical multistage pumps with stainless-steel bodies, stainless-steel impellers, shaft and outer sleeve. Maximum working pressures: T (oval flange): 16.0 bar. V (Victaullic & grooved), C (clamp flanges) & F (round flange) versions: 26.0 bar. Maximum operating temperature 100°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2110123
Size:
TPX1-TPX3 models - F (round flange) versions: DN25. TPX5-TPX20 models - F (round flange) versions: DN32-50. TPX1-TPX20 models - T (oval flange), V (Victaullic - EV; Grooved - VR), C (clamp flanges) & F (round flange) versions: DN32-50.
Marking:
Dutypoint, date of production (DD/MM/YYYY), pressure, temperature and other technical information on data plate on body.
Installation Requirements:
R001 R415
Expiry date:
31/10/2026
Model:
TPX1, TPX3, TPX5, TPX10, TPX15, TPX20, TPX30, TPX45, TPX65 & TPX95 Range of vertical multistage pumps Code example (TPX range): TPX 20 /15 A B C D E F G H J K L M N PMP/A. Where: TPX = Pump model TPX. 20 = Rated flow [m³/h] (varies: 1-95). /15 = No. of stages/impellers. (See model and stages below for more detail). A = No. of trimmed impellers, if "Empty" = none. B = Flange type: "F" - round; "T" - oval; "V" - Victaulic; "C" - clamp. C = Materials: "I" - (AISI304/EN1.4301); "N" (AISI316/EN1.4401). D = Motor power (kW x 10). E = Frequency: "5" - 50Hz; "6" - 60Hz. F = No. of motor poles: "Empty" - 2 poles; "4" - 4 poles. G = Motor type: "Empty" - without motor, "T" - 3-phase; "M" - 1-phase. H = Mechanical Seal: "Empty" - standard version (EV1-EV20 & 1VR-20VR versions only). J = Type of mechanical Seal: E1 (SiC-Carbon Graphite-EPDM) or E2 (SiC-SiC-EPDM). K = "Empty" - standard version, "H" - high pressure. L = "Empty" - standard version, "P" - passivated. M = "Empty" - standard version N = "Empty" - no motor, “IE..” motor efficiency class. PMP/A = cold formed pump casing. Code example (TPXR range): TPXR3/0700 A B C X-XXXX. Where: TPXR = Pump model. 3 = Rated flow [m³/h] (varies: 1-20). 07 = No. of stages/impellers. (See model and stages below for more detail). 00 = Impeller trim: 00 = no trim, A1 = 1A (one trimmed impeller), A2 = 2A (two trimmed impellers). A = Materials: "H" - (AISI304/EN 1.4301); "N" (AISI316/EN 1.4401). B = Flange type: "F" - round; "T" - oval; "V" - Grooved (Victaulic); "C" - clamp. C = Mechanical Seal: “1” - QBE; “2” - QQE. X-XXXX = Combination of numbers and letter relating to frame, speed, motor and electronics (does not affect water pathways). Last two digits can be empty for versions without a motor. Minimum and maximum number of stages (please note the oval flange models have a lower maximum, this is included in brackets as follows [15] to denote 15 stages): TPX1/TPXR1: stage from 2 to 37 [23] (50Hz) and from 2 to 25 [15] (60Hz); TPX3/TPXR3: stage from 2 to 33 [21] (50Hz) and from 2 to 23 [14] (60Hz); TPX5/TPXR6: stage from 2 to 36 [21] (50Hz) and from 2 to 23 [14] (60Hz); TPX10/TPXR10: stage from 2 to 24 [15] (50Hz) and from 2 to 17 [10] (60Hz); TPX15/TPXR15: stage from 1 to 17 [10] (50Hz) and from 1 to 12 [10] (60Hz); TPX20/TPXR20: stage from 1 to 17 [10] (50Hz) and from 1 to 10 [7] (60Hz).

Approval Holder:
Dutypoint Ltd.
Company Name
Dutypoint Ltd.
Address
Olympus Park, Quedgeley Gloucestershire
Postcode
GL2 4DH
General Email
sales@dutypoint.com

View All Listings by this Company

Print This Approval


#2304317

Range of cold water supply booster sets, consisting of between 2 & 4 pumps, modular stainless steel manifold system, servicing valve, non-return valve (not suitable for backflow protection) and an expansion vessel. Maximum working pressure 10.0 bar or 16.0 bar (identified on adhesive label on expansion vessel) Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2304317
Size:
DN50 to DN150
Marking:
Dutypoint Ltd. model, serial number and other technical information on adhesive label on base.
Installation Requirements:
R001 R415
Expiry date:
30/04/2028
Model:
VT2-05-xxxx VT2-10-xxxx VT2-15-xxxx VT2-20-xxxx VT3-05-xxxx VT4-05-xxxx VT3-10-xxxx VT3-15-xxxx VT3-20-xxxx VT4-10-xxxx VT4-15-xxxx VT4-20-xxxx Example of model: VT2-05-015T xxxx on end of model codes above denotes all motor size and type. Range: VT. Number of Pumps: 2. Nominal flow rate: (m³/hr) 05. Motor kW: (without decimal)15 (1.5kw). Voltage: (T=400/3/50 M=230/1/50) T

Approval Holder:
Dutypoint Ltd.
Company Name
Dutypoint Ltd.
Address
Olympus Park, Quedgeley Gloucestershire
Postcode
GL2 4DH
General Email
sales@dutypoint.com

View All Listings by this Company
Manufacturer:
Dutypoint Ltd.
Company Name
Dutypoint Ltd.
Address
Olympus Park, Quedgeley Gloucestershire
Postcode
GL2 4DH
General Email
sales@dutypoint.com

View All Listings by this Company

Print This Approval


#2312802

Range of cold water supply booster sets, incorporating stainless steel manifold system connecting 2 or 3 wholesome water pumps. The set also includes spherical valves, non-return valves (not intended or suitable for backflow protection) and expansion vessels. Maximum working pressure 10.0 bar. Cold water supply only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2312802
Size:
DN80 inlet x DN80 outlet flanged connections. DN50 inlet x DN65 outlet flanged connections.
Marking:
Dutypoint, model, serial number and technical information on adhesive label on base plate.
Installation Requirements:
R001 R415
Expiry date:
31/12/2028
Model:
DN50 Discharge Versions: Twin pump units: FR/VR2-03, FR/VR2-05, FR/VR2-10. Triple pump units: FR/VR3-03, FR/VR3-05, FR/VR3-10. DN80 Discharge Versions: Twin pump units: FR/VR2-15, FR/VR2-22. Triple pump units: FR/VR3-15, FR/VR3-22. The model is suffixed with two numbers to denote motor size and ‘LHT’.

Approval Holder:
Dutypoint Ltd.
Company Name
Dutypoint Ltd.
Address
Olympus Park, Quedgeley Gloucestershire
Postcode
GL2 4DH
General Email
sales@dutypoint.com

View All Listings by this Company
Manufacturer:
Dutypoint Ltd.
Company Name
Dutypoint Ltd.
Address
Olympus Park, Quedgeley Gloucestershire
Postcode
GL2 4DH
General Email
sales@dutypoint.com

View All Listings by this Company

Print This Approval


#2311337

Range of break tanks and pump sets incorporating a Type AB airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 10 bar. Cold water use only.

Section:
0009 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 - Type AB - Air gap with weir overflow.
WRAS Approval Number:
2311337
Size:
½” BSP (F) 1” BSP (F) 1 ¼” BSP (F)
Marking:
Dutypoint, address, Model, Serial No and pressure rating on adhesive label on panel.
Installation Requirements:
R001 R415 R574
Expiry date:
1/12/2028
Model:
VQ1 VQ2 FQ1** FC1 Example of Model Number: VQ1-05-015M Range: VQ (other options are FQ & FC) Number of Pumps: 1 Nominal Flow: 05 (m3hr) Motor kw (without decimal): 015 (1.5kw) Voltage: M (T=400/3/50 M=230/1/50) *Where 16Bar outlet pressure is required, the only component changed is the pressure vessel. ** the only difference between VQ1 and FQ1 is the electrical control type, so the VQ1 sample will also serve as the FQ1 sample

Approval Holder:
Dutypoint Ltd.
Company Name
Dutypoint Ltd.
Address
Olympus Park, Quedgeley Gloucestershire
Postcode
GL2 4DH
General Email
sales@dutypoint.com

View All Listings by this Company
Manufacturer:
Dutypoint Ltd.
Company Name
Dutypoint Ltd.
Address
Olympus Park, Quedgeley Gloucestershire
Postcode
GL2 4DH
General Email
sales@dutypoint.com

View All Listings by this Company

Print This Approval


Show Per Page
5102050Show All

Back To Directory Sections

Page of 1

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.