TEST SITE

Wolseley UK Approvals


#2204106

Range of quarter turn, lever handle operated spherical valves with nickel plated brass bodies, chrome plated brass balls and PTFE seals. For use with copper pipe BS EN 1057. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.

Section:
2260 Valves
Section Subtitle:
Spherical, metal.
WRAS Approval Number:
2204106
Size:
SEE MODELS
Marking:
MB (Brand of Navigator used under license by Wolseley), size, date of manufacture (MM/YY) on body. MB (Brand of Navigator used under license by Wolseley) ON/OFF, size and WRAS on lever.
Installation Requirements:
R001
Expiry date:
30/04/2027
Model:
Red/ Blue handle circlip reduced bore ball valve models: 236564 – CxC Brass Lever Ball Valve 15MM 236561 – CxC Brass Lever Ball Valve 22MM

Approval Holder:
Wolseley UK
Company Name
Wolseley UK
Address
K2 Kingmaker Court, Warwick Technology Park, Warwick
Postcode
CV34 6DY
Phone
01926 705792

View All Listings by this Company

Print This Approval


#2005058

Range of screw down stop valves with brass bodies. Fittings incorporate EPDM seat washers and PTFE seals. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.

Section:
2310 Valves
Section Subtitle:
Stop, metal, screw down.
WRAS Approval Number:
2005058
Size:
½” - 2” BSP (F) 15mm - 54mm compression 15mm - 20mm compression 15mm - 25mm compression 22mm - 25mm compression
Marking:
MB (Brand of Navigator used under license by Wolseley) Flow arrow, size and EN23 on body.
Installation Requirements:
R001
Expiry date:
31/05/2025
Model:
Compression stop cock for use with copper pipe: 236570 – CxC Brass Stopcock 15mm 236569 - CxC Brass Stopcock 22mm

Approval Holder:
Wolseley UK
Company Name
Wolseley UK
Address
K2 Kingmaker Court, Warwick Technology Park, Warwick
Postcode
CV34 6DY
Phone
01926 705792

View All Listings by this Company

Print This Approval


#2310393

Range of manually operated dual flush WC outlet valves. Cold water use only.

Section:
1305 Flushing Mechanisms
Section Subtitle:
WC. Except where specified, flushing valves within this section have only completed a limited number of the performance and endurance tests as stated in the "Regulators Specification for WC suites installed after 1st January 2001". The flush volume of valves within this section have not be verified by test. When installed in combination with a WC cistern and pan, further performance tests will be required.
WRAS Approval Number:
2310393
Size:
1 ½” BSP (M), 2” BSP (M).
Marking:
Wirquin moulded on body.
Installation Requirements:
R001 R571 R580 R581
Expiry date:
31/10/2028
Model:
B24004 NABIS manually operated dual flush WC outlet valves.

Approval Holder:
Wolseley UK
Company Name
Wolseley UK
Address
K2 Kingmaker Court, Warwick Technology Park, Warwick
Postcode
CV34 6DY
Phone
01926 705792

View All Listings by this Company

Print This Approval


#2312372

Range of single hole, single outlet (fixed) electronically controlled tap assemblies, (Chrome plated - brass bodies). Flow is controlled by a solenoid valve activated by via an infra-red sensor. The spout outlets incorporate plastic aerators. Maximum working pressure 10 bar. Maximum operating temperature 60°C.

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Tap with a non-touch methods of flow control and a single inlet. Products listed in this section utilise flow control methods that do not require touch to activate.
WRAS Approval Number:
2312372
Size:
½” BSP (M)
Marking:
Saracen on body.
Installation Requirements:
R001 R006
Expiry date:
31/12/2028
Model:
C66102

Approval Holder:
Wolseley UK
Company Name
Wolseley UK
Address
K2 Kingmaker Court, Warwick Technology Park, Warwick
Postcode
CV34 6DY
Phone
01926 705792

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 2 of 2

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.