Range of domestic water pressure booster pumps with brass impellors, plastic bodies and an accumulator. Models are supplied with a pressure reducing valve, isolation valve, inline strainer and non-return valve. Maximum working pressure 4.5 bar. Maximum operating temperature 35°C.
Range of shower booster pumps (either single or double) with acetal bodies and impellers and EPDM seals and NBR `O`-rings. Supplied with stainless-steel braided EPDM lined flexible hoses incorporating isolation valves Maximum working pressure 3.0 bar. Maximum operating temperature 65°C.
MBC 12-22WM & MBC 12-28WM models are wall mounted mains supply booster sets. They are supplied with two spherical isolation valves, a spherical bypass valve and two single check valve assemblies (suitable for backflow protection against Fluid Category 2). The check valve assemblies are to be installed in accordance with the manufacturers instructions, one upstream of the pump inlet and one after the bypass valve. The booster pump incorporates a plastic strainer on the inlet and a plastic flow regulator on the outlet and is housed within a wall mounted cabinet. MJ3 VM & MJ3 HM models are mains supply booster sets intended to be mounted on an expansion vessel (not supplied as part of the approval). They comprise of a pump, a suction and discharge manifold with bypass arrangement, and a spherical bypass valve which incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The booster pump incorporates a plastic strainer on the inlet and a plastic flow regulator on the outlet. Maximum working pressure 6.0 bar. Cold water use only.
Multistage, vertical booster pumps with a brass body and stainless steel pump housing, stainless steel impellers and EPDM ‘O’-rings. The 41782 (MV90 4M VSD) model includes a pressure transducer. Maximum working pressure 6.0 bar. Cold water use only.
‘Showermate Universal’ range of booster pumps with plastic bodies and impellers, stainless steel shafts, brass manifolds, NBR ‘O’-rings and EPDM seals. The product incorporates a pressure vessel. The outlet(s) incorporate(s) an approved single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection The inlet hose(s) supplied with this product incorporate(s) an isolation valve. Maximum working pressure 4.0 bar. Maximum operating temperature 65°C.
Monobloc assembly with a DZR brass body comprising of a stainless steel strainer, adjustable pressure reducing valve and two approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with two loose pressure gauges. For use with copper pipe (manufactured to EN1057). The product is also supplied with Maximum inlet supply pressure 6.0 bar. Maximum outlet pressure 0.8 bar to 6.0 bar. Maximum operating temperature 35°C.
Range of multistage pumps with brass suction and discharge bodies, stainless steel housing, shaft and impeller, and EPDM ‘O’-rings and seals. Maximum working pressure: 6.0 bar (41491 & 41492 models) or 9.0 bar (41493 & 41494 models). Maximum operating temperature 65°C.
Range of multistage pumps with brass suction and discharge bodies, stainless steel housing, shaft and impeller, and EPDM ‘O’-rings and seals. Maximum working pressure: 6.0 bar (46553 - Stuart CH 4-30 & 46554 - Stuart CH 4-40 models) or 9.0 bar (46555 - Stuart CH 4-50 &46556 - Stuart CH 4-60 models). Maximum operating temperature 65°C.
Range of booster pumps with stainless steel bodies, plastic impellers, and NBR ‘O’-rings. The products incorporate a temperature sensor, pressure sensor, pressure vessel and a non-return valve integral to the pump chamber. Maximum working pressure 6.5 bar. Maximum operating temperature 75°C.
Range of single and twin line shower booster pumps with plastic bodies, plastic impellors, stainless steel motor, NBR ‘O’-rings and EPDM seals. Each suction port incorporates a combined EPDM washer and stainless steel strainer. Maximum working pressure 3.0 bar. Maximum operating temperature 65°C.
Range of horizontal self-priming multistage pumps with stainless steel bodies, stainless steel impellers, shaft and outer sleeve. Maximum working pressure 10.0 Bar Maximum operating temperatures: EH Three phase models 85°C, EH Single phase models 55.0°C and EHsp models 35°C.
Range of vertical multistage booster pumps, with stainless steel bodies and impellors. Maximum working pressure: See models Maximum working temperature 85°C.
Range of electrolytic water conditioning units consisting of stainless-steel tube with a copper/zinc alloy sacrificial anode and brass inlet and outlet connections. Compression models are for use with copper pipe (manufactured to BS EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of water pressure booster pumps, comprising of a multi-stage pump with a brass body, and an expansion vessel. The product is supplied with a strainer and two stainless steel braided EPDM lined flexible hose assemblies. The outlet assembly incorporates a non-return valve, not suitable for backflow protection. Maximum working pressure models 46601 and 46602 6.0 bar, models 46622 and 46624 9.0 bar. Cold water use only.
Range of centrifugal multi-stage horizontal pressure booster pumps with brass bodies. The 46593, 46594, 46595 and 46610 models include a non-return valve (not suitable for backflow protection) and an expansion vessel. They are also supplied inline strainer and two stainless steel braided EPDM lined flexible hose assemblies with 1” captive nut x 1" BSP (M) end connection for the inlet and outlet. Maximum working pressure models 46578, 46596, 46605 and 46606: 6.0 bar, Models 46593, 46594, 46595 and 46610: 9.0 bar. Maximum operating temperature 65°C
Range of one piece water storage cisterns with a screened breather and over flow. Model 46714 iBoost+200 has a rectangular weir overflow Model 46712 iBoost+200 has a circular overflow Cold water only.
Range of water pressure booster sets with a cold water storage cistern and booster pump. All models incorporate a non-return valve, not suitable for backflow protection. These models have an AG air gap suitable for fluid category 3 protection. Maximum working pressure 6.0 bar. Cold water use only.
Range of water pressure booster sets with a cold water storage cistern and booster pump. All models incorporate a non-return valve, not suitable for backflow protection. These models have an AB air gap suitable for fluid category 5 protection. Maximum working pressure 6.0 bar. Cold water use only.
Page of 1
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.