Cistermiser Ltd Approvals


#2307042

DC pipe interrupter with nylon body. The inlet incorporates a plastic flow regulator. Maximum working pressure 10 Bar Cold water use only

Section:
0014 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2. Type DC - Pipe interrupter with permanent atmosphere vent. The device must be fitted with the lowest point of the air aperture not less than 150mm above the free discharge point, or spillover level of an appliance, and have no valve, flow restrictor or tap on its outlet.
WRAS Approval Number:
2307042
Size:
¾” BSP (F) inlet x ¾” BSP (M) outlet
Marking:
Cistermiser on body
Installation Requirements:
R001 R165
Expiry date:
31/07/2028
Model:
EF/BF

Approval Holder:
Cistermiser Ltd
Company Name
Cistermiser Ltd
Address
Unit 1 Woodley Park Estate 59/69 Reading Road
Postcode
RG5 3AN
Phone
+44 118 969 1611 Fax: 0118 944 1426
General Email
Alicja.Wielechowska@cistermiser.co.uk

View All Listings by this Company
Manufacturer:
Cistermiser Ltd
Company Name
Cistermiser Ltd
Address
Unit 1 Woodley Park Estate 59/69 Reading Road
Postcode
RG5 3AN
Phone
+44 118 969 1611 Fax: 0118 944 1426
General Email
Alicja.Wielechowska@cistermiser.co.uk

View All Listings by this Company

Print This Approval


#2307323

IR sensor activated dual flush WC siphon valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. Cold water only.

Section:
1305 Flushing Mechanisms
Section Subtitle:
WC. Except where specified, flushing valves within this section have only completed a limited number of the performance and endurance tests as stated in the "Regulators Specification for WC suites installed after 1st January 2001". The flush volume of valves within this section have not be verified by test. When installed in combination with a WC cistern and pan, further performance tests will be required.
WRAS Approval Number:
2307323
Size:
See model.
Marking:
Cistermiser etched on IR Sensor.
Installation Requirements:
R001 R571 R581
Expiry date:
31/07/2028
Model:
EasyflushEVO 1.5" & EasyflushEVO 2".

Approval Holder:
Cistermiser Ltd
Company Name
Cistermiser Ltd
Address
Unit 1 Woodley Park Estate 59/69 Reading Road
Postcode
RG5 3AN
Phone
+44 118 969 1611 Fax: 0118 944 1426
General Email
Alicja.Wielechowska@cistermiser.co.uk

View All Listings by this Company
Manufacturer:
Cistermiser Ltd
Company Name
Cistermiser Ltd
Address
Unit 1 Woodley Park Estate 59/69 Reading Road
Postcode
RG5 3AN
Phone
+44 118 969 1611 Fax: 0118 944 1426
General Email
Alicja.Wielechowska@cistermiser.co.uk

View All Listings by this Company

Print This Approval


#2312351

‘Tanktronic‘ range of water level monitoring kits comprising of a main control unit, vent box and single or double stainless steel sensors. Open outlet use only. Maximum operating temperature 23°C

Section:
1530 Miscellaneous Fittings
WRAS Approval Number:
2312351
Size:
24.50MM OD (sensor outer diameter – product has no water connections).
Marking:
Tanktronic, Keraflow, model, serial no & production info on sensor box & vent box assembly.
Installation Requirements:
R001 R008
Expiry date:
31/12/2028
Model:
TT/41 - Tanktronic Main Control Unit with Single 3m Sensor and Vent box assembly, TT/42 - Tanktronic Main Control Unit with Single 5m Sensor and Vent box assembly, TT/43- Tanktronic Main Control Unit with Twin 3m Sensor and Vent box assembly, TT/44 - Tanktronic Main Control Unit with Twin 5m Sensor and Vent box assembly.

Approval Holder:
Cistermiser Ltd
Company Name
Cistermiser Ltd
Address
Unit 1 Woodley Park Estate 59/69 Reading Road
Postcode
RG5 3AN
Phone
+44 118 969 1611 Fax: 0118 944 1426
General Email
Alicja.Wielechowska@cistermiser.co.uk

View All Listings by this Company
Manufacturer:
Cistermiser Ltd
Company Name
Cistermiser Ltd
Address
Unit 1 Woodley Park Estate 59/69 Reading Road
Postcode
RG5 3AN
Phone
+44 118 969 1611 Fax: 0118 944 1426
General Email
Alicja.Wielechowska@cistermiser.co.uk

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 2 of 2

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.